In regard to MMS Fail, there are three types of errors as shown below.

The respective methods of taking measures are described below.

1) FPGA***

This is a configuration error of FPGA. If the associated FPGA is of an input board, try to remount the board or check the flexible cable connections or reinstall the FPGA data.

In the case of the other FPGA errors, also try to reinstall the FPGA data. If

this check is difficult to carry out, replace the associated board as a whole.

2) Default Data

The data involved some deficiency at the time of shipment from the factory. Reinstall the data.

3) User Data

This error is caused by a certain deficiency in the user data. As required,

copy the user data in the PC so that checks can be made to see the elimination of the problem in the state that the default signal data are used after the execution of factory default. Since part of or all of the previously copied user data have been broken, reuse of these data is not recommendable. If the data are used for the purpose of setup data checks, they

should be cleared later.

133MM Reset (Command:Param1)Executed to reset Built-in MMS

Param1: When executed to reset Built-in MMS.

001: Executed to reset Built-in MMS when no

communications between projector

main system and MMS.

T-001: Executed to reset Built-in MMS when no

communication between external

projector and MMS.

1. This message shows the projector reset the MM3000B because of no responses.

If MMS Comm Fail occurs, see the MM3000B service manual.

140DLP CommR Fail(Param1Param2Param3:Param4)Communication failure with the ICP board.

(Communication I/F is RS-232C)

Param1: First portion of ICP command.

Param2: Second portion of ICP command.

Param3: Third portion of ICP command.

Param4: Error type (“Con”, “Tx”, Rxn”, “Nack”,

“Tout”)

e.g.) DLP CommR Fail(010203:Nak=0001H)

ICP returns “NAK” response to the command, “01,

02, 03, …”.

1. If ICP is being updated by ICP & Enigma Control Program without "Special Mode",

this message will be shown.

2. If ICP is reset by ICP & Enigma Control Program, this message will be shown.

3. Retry the projector operation.

4. Reset the ICP board and retry the projector operation.

5. Check the connection between FSB and MOTHER PWB.

6. Check the power supply voltage for the ICP board.

141DLP CommE Fail(Param1Param2Param3:Param4)Communication failure with the ICP board.

(Communication I/F is Ethernet)

Param1: First portion of ICP command.

Param2: Second portion of ICP command.

Param3: Third portion of ICP command.

Param4: Error type (“Con”, “Tx”, Rxn”, “Nack”,

“Tout”)

e.g.) DLP CommR Fail(010203:Nak=0001H)

ICP returns “NAK” response to the command, “01,

02, 03, …”.

1. If ICP is being updated by ICP & Enigma Control Program without "Special Mode",

this message will be shown.

2. If ICP is reset by ICP & Enigma Control Program, this message will be shown.

3. Retry the projector operation.

4. Reset the ICP board and retry the projector operation.

5. Check the connection between FSB and MOTHER PWB.

6. Check the power supply voltage for the ICP board.

145SensorFail Outside Air(Param1)Sensor (Outside Air) read error.

Param1: Get/Set

Failed to get/set data from/to sensor board.

146SensorFail LPSU Intake(Param1)Sensor (LPSU Intake) read error.

Param1: Get/Set

Failed to get/set data from/to sensor board.

147SensorFail Exhaust(Param1)Sensor (Exhaust) read error.

Param1: Get/Set

Failed to get/set data from/to sensor board.

148SensorFail DMD-B(Param1)Sensor (DMD-B) read error.

Param1: Get/Set

Failed to get/set data from/to sensor board.

150Fan0 Stop(Param1)Fan0 has stopped.

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

151Fan1 Stop(Param1)Fan1 has stopped.

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

152Fan2 Stop(Param1)Fan2 has stopped.

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

153Fan3 Stop(Param1)Fan3 has stopped.

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

154Fan4 Stop(Param1)Fan4 has stopped.

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

155Fan5 Stop(Param1)Fan5 has stopped.

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

156Fan6 Stop(Param1)Fan6 has stopped.

Param1: Rotating Speed(Decimal)

1. When the projector is NC3200S, refer 2 to 4 item firstly

2. (NC3200S) Check the system log.

3. (NC3200S) When the GPSU(24V) fail was occurred, update the firmware to release

package 2.31.

4. (NC3200S) or temporary countermeasure is to re-start ( cold start ) the projector.

5. Check the failed fan and replace failed fan.

6. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix

157Fan7 Stop(Param1)Fan7 has stopped. (Only for NC3200S)

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

158Fan8 Stop(Param1)Fan8 has stopped. (Only for NC3200S)

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

159Fan9 Stop(Param1)Fan9 has stopped. (Only for NC3200S)

Param1: Rotating Speed(Decimal)

1. Check the failed fan and replace failed fan.

2. Check connector POCN5 on PJDIV PWB.

For fan layout, see the appendix.

160GPSU Fan Stop GPSU Fan has stopped.1. Check the connection between POPSM on PJDIV PWB and GPSU. Check the connection between AC PWB and GPSU.

2. Replace GPSU Fan.

3. Check GPSU.

162Lamp Fan0 Stop(Param1)Lamp cooling fan0 has stopped.

Param1: Rotating Speed (Decimal) or HW Prt (Hartware protection)

132MMS Fail Built-in MMS internal error.

1. Check the connection between T-SENSE PWB and POCN1 on PJDIV PWB.

2. Check the TSENS PWB.

1. Check the connection between Fan unit and POCN5 on PJDIV PWB.

For fan layout, see the appendix.

163Lamp Fan1 Stop(Param1)

Lamp cooling fan1 has stopped.

Param1: Rotating Speed (Decimal) or HW Prt (Hartware protection)

164ICP Fan Stop(Param1)

ICP fan has stopped.

Param1: Rotating Speed(Decimal)

1. Check the fan attached on CPU PWB.

2. Replace fan.

3. Replace CPU PWB.

165GPI MACRO(n) Selection Invalid

Selection of preset button (n) through GPI is invalid because metadata is enabled.n: Preset Button Number(1-8)

1. When the GPI title selection is requested during the operations are not allowed, this message will be shown.

166GPI Control(Param1) Invalid

Projector control through GPI is invalid because projector is busy.

Param1: Canceled GPI control:Lamp Off/ On , Mute Off/ On/Power On/Off

Selection of preset button n (n=1..8)

1. When the GPI control is requested during the projector is busy, this message will be shown.170OverTemp.Outside Air(Param1)Set inside temperature (Outside Air) is abnormal Param1: Temperature(in deg)

171OverTemp.Precaution(Param1)Set inside temperature(LPSU Intake) is close to over

temperature.

Param1: Precaution temperature(in deg)

172OverTemp.Exhaust(Param1)Set inside temperature (Exhaust) is abnormal

Param1: Temperature(in deg)

173OverTemp.DMD-B(Param1)Set inside temperature (DMD-B) is abnormal Param1: Temperature(in deg)174

Bulb Entry

No selection of current bulb.

1. Setup the new bulb entry while the projector is in standby.

177Tamper Fail(Param1)

Service door tamper switch of projector is open.Param1 : Location of tampering switch.(Param1 is encrypted)

LCD: Decrypted while projector is service mode or higher.

Log: Decrypted to view while DCC is service mode or higher.

1. Check the (Param1) which tells which switch is activated.

2. Check if the side covers and lens cover are closed propely.

3. Check if the tamper switch lever is broken.

4. Check the connection between TAMPER PWB and POCN2/POCN7 on PJDIV PWB.

5. Check TAMPER PWB.178Marriage Tamper Fail(Param1)

Marriage tamper switch of projector is open.Param1 : Location of tampering switch.(Param1 is encrypted)

LCD: Decrypted while projector is service mode or higher.

Log: Decrypted to view while DCC is service mode or higher.

If Param1=0, reseat Circuit Box.

If Param1=1,

1. Check if cover plate or option PWB is seated at option slot A.

2. Check the connection between TAMPER PWB and PO6012 on PJDIV PWB.

3. Check TAMPER PWB.

4. Check if ICP PWB/SIB is seated on MOTHER PWB properly.180CPU Fail(Mem) Param1: Param2<->Param3

System Test Failed.(Memory)Param1-3: Detailed Test results.

1.Check the CPU PWB

187GPSU(24V) Fail Power supply is abnormal.(24V)

1. When the projector is NC3200S, refer 2 to 4 item firstly.

2. (NC3200S) Check the system log.

3. (NC3200S) When the GPSU(24V) fail was occurred, update the firmware to release package 2.31.

4. (NC3200S) or temporary countermeasure is to re-start ( cold start ) the projector.

5. Check the DC power supply voltage.

6. Check the connection between GPSU and POPSM on PJDIV PWB.

201Error Log Write Fail Failed to store logs into projector system. 1. Replace CPU PWB.

210Unknown LPSU Model(Param1)

Unexpected LPSU is attached.

Param1: Unexpected LPSU Product Model 1. Check if the proper LPSU is used.2. Replace LPSU.

211LPSU Fan Stop LPSU fan has stopped.

1. Check if the LPSU is powered on.

2. Replace LPSU.

21312V Outside range(Param1)

12V supply is out of range.

Param1: Captured voltage value.LCD: invalid Log : valid

1. Check the 12v line.

2. Check the connection between GPSU and PO6010 on MOTHER PWB.

21424V Outside range(Param1)

24V supply is out of range.

Param1: Captured voltage value.LCD: invalid Log : valid

1. When the projector is NC3200S, refer 2 to 4 item firstly.

2. (NC3200S) Check the system log.

3. (NC3200S) When the GPSU(24V) fail was occurred, update the firmware to release package 2.31.

4. (NC3200S) or temporary countermeasure is to re-start ( cold start ) the projector.

5. Check the 24v line.

6. Check the connection between GPSU and POP24 on PJDIV PWB.

215Lamp Filter Time Over(Param1)

The time to exchange lamp filter. (Future use)Param1: usage hours

1. Change filters

216Body Filter Time Over(Param1)The time to exchange body filter. (Future use)Param1: usage hours

1. Change filters

220AC On Fan Exchange Time The time to exchange Fan(AC On)

1. Replace AC On Fan(Fan6) and clear AC On Fan usage time.

221Power On Fan Exchange Time The time to exchange Fan(Power On)

NC2000C/NC1200C

1. Replace Power On Fan(Fan0..5 and 7) and clear Power On Fan usage time.

NC3200S

1. Replace Power On Fan(Fan0..5 and 7..9) and clear Power On Fan usage time.

222Lamp Fan Exchange Time The time to exchange Lamp Fan

1. Replace Lamp Cooling Fan 0 and 1 and clear Lamp Cooling Fan usage time.

230Router Fail(Param1)

Failed to control router.Param1:

“Connect” : Failed to connect to router “Tx” : Transmit error “Rx” : Receive error

“Tout” : Communication timeout

“Msg Format” : Unexpected data received “Data”: No data to setup router “Verify”: Setting verify error 1. If the router unit is replaced to the new, execute "NewRouterSetup" for projector use.2. Power-cycle the projector.

3. Check the LAN cable connection between Router unit and MOTHER PWB.

4. Execute Factory Default - LAN.

5. If the router firmware is Version1.3 Release01, update to Version1.4 Release01.

231SensorFail Opt

Failed to control light sensor.

1. Check the connection between POCN3 on PJDIV PWB and LSENS PWB.

2. Check the LSENS PWB.232MAC Write Fail Failed to setup MAC address of CPU board.

1. Replace CPU PWB.

2. Chekc LED on driver PWB.

3. Check the failed fan and replace the fan.

1. Check the ambient temperature. It should be 35 degC or lower.

2. Check if there is any problem on suction air and exhasut air.

3. Check the air filter clogging.

4. Check if the ventilation system is operated with required specification.

5. Check the TSENS PWB

233Illegal MAC Address Router WAN MAC address is illegal.1. Power-cycle the projector.

2. Replace the Router unit and execute "NewRouterSetup."

235Router Self Check Fail

(Param1, Param2, Param3)

Router health-check error.

Param1 : Health check error timing

“INIT”: After AC-ON

“STBY”: During standby

“ RUN”: During power-on

Param2: Health check result

“2”: Factory default

“3”: No responses(Dead lock or something)

“4”: Unstable status

“5”: Factory default and unstable status

“6”: Defective(possibly “2” to “5”)

Param3: router response result

(Valid when Param2 is “4” and “5”)

N of4ping responses

1. Check the connection of lan cable.

2. Check router.

240SIB Comm Fail(Param1Pram2Param3Param4)Failed to communicate with SIB.

Param1:

“Connect”, “Tx”, “Rx”, “Nack”, “Tout”

Param2: First portion of SIBcommand.

Param3: Second portion of SIB command.

Param4: Third portion of SIB command.

When Param1 is “Nack”, nack data is added after

Param4.

e.g.) SIB Comm Fail(Nack)010203:0001H

1. Check LAN cable between Router and Mother(PO6201)

2. Check connection of between SIB PWB (IC1600,IC1604) and Mother PWB

241SIB Error(Param1)SIB internal error.

Param1: SIB internal error status

“FPGA Open”: Failed to open serial I/F

“FPGA Tx:nnn”: FPGA send error

(nnn: failed send command)

“FPGA Rx:nnn”: FPGA receive error

(nnn: failed receive command)

“MEM Open”: Device driver open error

“MEM Read”:Device driver read error

1. Check SIB PWB

242SIB FPGA Reboot Executed to re-boot SIB FPGA for recovery. 1. Check SIB PWB

250Fan0 Stop Precaution(Param1)Fan0 Stop Precaution

Param1: Rotating Speed(Decimal)

251Fan1 Stop Precaution(Param1)Fan1 Stop Precaution

Param1: Rotating Speed(Decimal)

252Fan2 Stop Precaution(Param1)Fan2 Stop Precaution

Param1: Rotating Speed(Decimal)

253Fan3 Stop Precaution(Param1)Fan3 Stop Precaution

Param1: Rotating Speed(Decimal)

254Fan4 Stop Precaution(Param1)Fan4 Stop Precaution

Param1: Rotating Speed(Decimal)

255Fan5 Stop Precaution(Param1)Fan5 Stop Precaution

Param1: Rotating Speed(Decimal)

256Fan6 Stop Precaution(Param1)Fan6 Stop Precaution

Param1: Rotating Speed(Decimal)

257Fan7 Stop Precaution(Param1)Fan7 Stop Precaution

Param1: Rotating Speed(Decimal)

258Fan8 Stop Precaution(Param1)Fan8 Stop Precaution

Param1: Rotating Speed(Decimal)

259Fan9 Stop Precaution(Param1)Fan9 Stop Precaution

Param1: Rotating Speed(Decimal)

260Lamp Fan0 Stop Precaution(Param1)Lamp Fan0 Stop Precaution Param1: Rotating Speed(Decimal)

261Lamp Fan1 Stop Precaution(Param1)Lamp Fan1 Stop Precaution Param1: Rotating Speed(Decimal)

262Pump Stop Precaution(Param1)Pump Stop Precaution

Param1: Rotating Speed(Decimal)

263ICP Fan Stop Precaution(Param1)ICP Fan Stop Precaution

270SD Tamper Terminate(Param1)Terminated service door tamper event latched by Enigma

board.

LCD: Not supported

Log: Supported

1. Check tamper SW

280Bulb Warranty Over Bulb warranty time over 1. Change the lamp bulb to new one.

301System Error ICP board error 1. Check connection between ICP PWB and Mother PWB.

2. Check connection between SIB PWB and ENIGMA PWB.

3. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

4. Check ICP board.

302Self Test Error ICP board error

303Install Release Package Error ICP board error

304Load Release Package Error ICP board error

305Key Error ICP board error 1.Check ICP board.

306Certificate Error ICP board error 1. Check connection between ICP PWB and Mother PWB.

2. Check connection between SIB PWB and ENIGMA PWB.

3. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

4. Check ICP board.

317ICP Normal Configuration Error ICP board error

318ICP Boot Configuration Error ICP board error 319FMT Normal Configuration Error ICP board error 320FMT Boot Configuration Error ICP board error 321FMT Satellite Configuration Error ICP board error 322 1.20V Supply out of range ICP board error 323 1.80V Supply out of range ICP board error 324 2.50V Supply out of range ICP board error Preper DC fan of error and replace to new DC fan.

1. Check connection between ICP PWB and Mother PWB.

2Check Frimwarea version of both SIB PWB and ENIGMA PWB

1. Check connection between ICP PWB and Mother PWB.

2. Check connection between SIB PWB and ENIGMA PWB.

3. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

4. Check ICP board.

325 3.30V Regulator out of range ICP board error

326ICP FPGA Temperature out of range ICP board error

327FMT FPGA Temperature out of range ICP board error

328ICP Flash Update Error ICP board error

329FMT Sequence Data File Mismatch ICP board error

330FMT DMD Data File Mismatch ICP board error

331FMT Flash Checksum Error - Sequence Data ICP board error

332FMT Flash Checksum Error - DMD Data ICP board error

333Satellite Hardware Mismatch ICP board error

334FMT Flash Update Error ICP board error

335Red Satellite Reports Reset Cinema board error

336Red Satellite Serial Link Error Cinema board error

337Red Satellite Firmware Configuration Error Cinema board error

338Red DAD1000 Bias Under Voltage Error Cinema board error

339Red DAD1000 Reset Under Voltage Error Cinema board error

340Red DAD1000 Offset Under Voltage Error Cinema board error

341Red DAD1000 Thermal Shutdown Error Cinema board error

342Green Satellite Reports Reset Cinema board error

343Green Satellite Serial Link Error Cinema board error

344Green Satellite Firmware Configuration Error Cinema board error

345Green DAD1000 Bias Under Voltage Error Cinema board error

346Green DAD1000 Reset Under Voltage Error Cinema board error

347Green DAD1000 Offset Under Voltage Error Cinema board error

348Green DAD1000 Thermal Shutdown Error Cinema board error

349Blue Satellite Reports Reset Cinema board error

350Blue Satellite Serial Link Error Cinema board error

351Blue Satellite Firmware Configuration Error Cinema board error

352Blue DAD1000 Bias Under Voltage Error Cinema board error

353Blue DAD1000 Reset Under Voltage Error Cinema board error

354Blue DAD1000 Offset Under Voltage Error Cinema board error

355Blue DAD1000 Thermal Shutdown Error Cinema board error

356RTC Error Cinema board error 1. Check ICP PWB

400Enigma Comm Fail(Param1Param2Param3:Param4)No communication with the Enigma board.

Param1: First portion of Enigma command.

Param2: Second portion of Enigma command.

Param3: Third portion of Enigma command.

Param4: Error Type

“Conn=x”, “Tx”, “Rxn”, “Nack=xxxxH”,

“Tout=xxxx”

1. Check connection between ICP PWB and Mother PWB.

2. Check connection between SIB PWB and ENIGMA PWB.

3. Check LAN Connector of Moter PWB.

4. Check LAN IP address of SIB PWB.

5. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

410System Error Enigma Status error 1. Check connection between ICP PWB and Mother PWB.

2. Check connection between SIB PWB and ENIGMA PWB.

3. Check LAN Connector of Moter PWB.

4. Check LAN IP address of SIB PWB.

5. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

411Self Test Error Enigma Status error

412Install Release Package Error Enigma Status error

413Load Release Package Error Enigma Status error

414TI Login List Package Error Enigma Status error

415Security Officer Login List Package Error Enigma Status error

419Certificate or Key Error Enigma Status error

420ICP Communications Status Enigma Status error

426User Loader Integrity Error Enigma is in FIPS error state.(Integrity check error) 427Main Application Integrity Error Enigma is in FIPS error state.(Integrity check error) 428RNG Hardware Integrity Error Enigma is in FIPS error state.(Integrity check error) 429DRNG Algorithm Integrity Error Enigma is in FIPS error state.(Integrity check error) 430RSA Algorithm Integrity Error Enigma is in FIPS error state.(Integrity check error) 431AES Algorithm Integrity Error Enigma is in FIPS error state.(Integrity check error) 432HMAC Algorithm Integrity Error Enigma is in FIPS error state.(Integrity check error)1. Check cable betwwn FSB and Moter PWB

2. Check ICP PWB connection between ICP and Mother.

3. Check ICP PWB.

2. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

3. Check ICP board.

433SHA Algorithm Integrity Error Enigma is in FIPS error state.(Integrity check error)

434TLS Integrity Error Enigma is in FIPS error state.(Integrity check error)

435FPGA Configuration Integrity Error Enigma is in FIPS error state.(Integrity check error)

436FPGA CineLink 2 Decryption Integrity Error Enigma is in FIPS error state.(Integrity check error)

437RTC Error Enigma is in FIPS error state.(Integrity check error)

442FPGA Configuration Error Enigma Status error

443FPGA Temperature out of range Enigma Status error

446RNG Hardware Duplicate Output Error Enigma is in FIPS error state.(Integrity check error)

447DRNG Algorithm Duplicate Output Error Enigma is in FIPS error state.(Integrity check error)

450 1.20V Supply out of range Enigma Status error

451 1.80V Supply out of range Enigma Status error

452 2.50V Supply out of range Enigma Status error

453 3.30V Regulator out of range Enigma Status error

458SelfTest User Loader Integrity Error Enigma is in FIPS error state.(Self test result)

459SelfTest Main Application Integrity Error Enigma is in FIPS error state.(Self test result)

460SelfTest RNG Hardware Integrity Error Enigma is in FIPS error state.(Self test result)

461SelfTest DRNG Algorithm Integrity Error Enigma is in FIPS error state.(Self test result)

462SelfTest RSA Algorithm Integrity Error Enigma is in FIPS error state.(Self test result)

463SelfTest AES Algorithm Integrity Error Enigma is in FIPS error state.(Self test result)

464SelfTest HMAC Algorithm Integrity Error Enigma is in FIPS error state.(Self test result)

465SelfTest SHA Algorithm Integrity Error Enigma is in FIPS error state.(Self test result)

466SelfTest TLS Integrity Error Enigma is in FIPS error state.(Self test result)

467SelfTest FPGA Configuration Integrity Error Enigma is in FIPS error state.(Self test result)

468SelfTest FPGA CineLink. 2 Decryption Integrity Error Enigma is in FIPS error state.(Self test result)

474Security Tamper Security tamper condition exists. 1. Replace Enigma board. 475Top Side Security Enclosure Open Security tamper condition exists. 1. Replace Enigma board. 476Bottom Side Security Enclosure Open Security tamper condition exists. 1. Replace Enigma board. 477Security Battery Event Battery tamper condition exists. 1. Replace Enigma board. 478Software Commanded Zeroization Destroyed Enigma key by software command. 1. Replace Enigma board. 481Security Enclosure Not Armed Enigma security not armed. 1. Do the Arm-Tamper.

482Physical Marriage Tamper Latched physical marriage tamper condition on Enigma

board.

1. Check physical Marriage tamper.

483Logical Marriage Tamper Logical marriage tamper condition exists. 1. Do re-marrage function. 484Marriage NOT Active Marriage has NOT been established (active). 1. Do re-marrage function. 486Service Door Tamper Latched service door tamper condition on Enigma board1. Check tamper SW

487Security Log Error Security log is full.Security log is full.

Cinema server delete the security log of projector. Confirm this issue to vender of cinema server.

488Security Battery Low Warning Close to “Security Battery Low”. 1. Charge serucity battery.

489Security Log Warning Close to “Security Log Error”.Security log is full.

Cinema server delete the security log of projector.

Confirm this issue to vender of cinema server.

1. Check connection between ICP PWB and Mother PWB.

2. Check connection between SIB PWB and ENIGMA PWB.

3. Check LAN Connector of Moter PWB.

4. Check LAN IP address of SIB PWB.

5. Check Frimwarea version of both SIB PWB and ENIGMA PWB.

1数字放映机安装要求2011

BARCO 数字电影放映机安装要求 为了及时安全的安装贵影院的数字放映设备,影院应按下列做好相应准备。如场地条件未达到安装要求,安装人员可以推迟安装(直到达到要求)。 一、对环境的要求 - 机房温度:+10℃-30℃(存放:-15℃到+60℃)建议机器运行环境应保持合适的环境温度。 - 机房湿度:5% -75% (存放:5%-95%),建议机房配备温湿度计,时常监测。湿度大的地区装抽湿机。- 粉尘、烟尘: 可吸入颗粒PM10 应小于0.15mg/m3(中华人民共和国室内空气质量标准GB/T18883- 2002),无烟尘(禁止在放映机房吸烟,防止餐厅油烟及爆米花机烟尘流入),应定期检查。 - 空调:空调进风口,不要安排在放映机上方,以免万一冷凝水滴到机器里面。 - 进风:由于放映机需要很强的抽风,使机房处于空气负压,因此应有等量的新风进入放映间,新风应该是顺畅清洁的,因此应有专用通道和一定的过滤设施,特别是如有临街开窗的情况,最好加装过滤器。- 防火喷淋头:建议不要安排在放映机正上方,以免不必要的损失。 二、搬运通道及机位空间准备: 通道最窄处应大于102cm,放映间门/楼梯最窄处应大于80cm,转弯处空间130cm。 注:数字放映机最大外包装尺寸和重量如下:(安装前组织好搬运人力4 - 6 ) 放映机+标准底座整体尺寸图如下: B系列放映机C系列放映机 DP2K-xCLP放映机 S系列放映机 DP2K-6E

三、排风。 四、电源要求: - 额定供电电压:应稳定,要求在额定电压值±10%,如经常有电压不稳,电源干扰,建议加装稳压电源、净化电源或UPS,特别是配有IMB或IMS服务器的建议配备,而且运行过程中应定期检查。 - 交流电相位的平衡及分配:尽量避免将放映机的相线与大功率用电设备及变频设备(例如空调、音频功放)安装在同一相线上,避免电源干扰。注意各相位的分配使3相电负载尽量平衡。 -零-地间电压<1.2v。 五、放映窗口要求 -窗口尺寸:符合规范要求,不易过大,带喇叭形外口,以免挡光、影响隔音效果和干扰光。 单机:建议400×300mm(内口); 双机:并排双机:建议500×400mm,与银幕中心轴线对称 堆叠双机:根据现场情况定制,对于xxB机型,窗口宽500mm。 - 窗口中心高度: 1250 ±50mm(堆叠双机需特殊定制,xxB建议窗口底边到地>700mm) - 数字机窗口尽量靠近银幕中心轴线; - 窗玻璃:透光率好(>95%)、反射小、变色小的光学玻璃,并处理好隔音问题; - 配置防火闸门; - 配备观察窗,在机器右方便于操作,最好加可关闭装置,以防干扰光到影厅。

巴可放映机-巡检操作指导

巴可放映机-巡检操作指导 目的:为了更详细的了解放映机可能潜在的故障 整体巡检进度时间大约需要(I) 120分钟或(II)240分钟 巡检步骤如下: 一、检查影厅信息:5分钟 1、检查机房温度/湿度/通风/信息并记录入《巴可数字放映机现场检查维护报告》 2、询问影院方银幕的增益情况、银幕尺寸、投影距离、使用年限并记录入《巴可数字放映机现场检查维护报告》 3、主观的影像质量评价。发黄?发白?灰暗?是否需要进行光路清洁?与影院主管协商该事宜。 二、清洁:10分钟(注意不要用气泵清洁) 1、清洁整体机器外壳灰尘。用干净的抹布擦拭,如有难以擦拭的污渍请将抹布蘸清水进行擦拭。注意勿擦拭电路部分。 2、将机器外壳打开。清洁放映机自带的3片过滤网。S1如果HEPA 较黑(不透光)无法继续使用,建议用户购买更换(作标记)。S2可用毛刷将灰尘扫去,或用清水冲洗。注意:需要保证过滤网完全干燥后才能装入放映机。 3、检查各进风口情况。有灰尘的需要毛刷扫除用吸尘器将灰尘吸走,切记不能用高气压类气泵进行吹气。 4、将各电路板拔出,用毛刷将板卡上的灰尘扫去 5.。放映窗玻璃清洁。

三、光学部件: 光路I:20分钟,除引擎光管内部以外的光路 1、将镜头拔出,用镜头布清洁镜头内外面的灰尘。 2、打开光闸,用镜头布擦拭引擎出光口。 3、将灯箱拔出,用镜头布擦拭折射镜(Cold mirror),擦拭引擎光入口(integrator rod)。 4、将氙灯从灯箱内拿出,放置于安全的地方暂存。擦拭反光碗、滤光镜UV。如有污迹,需进行特殊清洁处理。光路II:120分钟,包括引擎光管内部全部光路 见引擎内部光路清洁 四、冷却系统:3分钟 1、检查排风机的风速。C系列需满足8-12米/秒。B系列需满足12-15米/秒。注意风扇状况。 2、检查液体压力。S1满足气压指针1-1.5pa值。S2液面高于MIN 低于MAX值。 五、氙灯/灯箱:3分钟 1、状况,观察氙灯运行情况。记录当前情况。稳定?闪烁?变黑?询问备用灯情况。 2、记录当前灯工作时的电流、功率(对应亮度测量值)。 3、记录当前灯使用寿命情况、点灯次数。记录该机器所使用最长/最短氙灯寿命。 4. 检查灯箱阳极支架(R863206K,R863207K)是否已更新(InfoT

数据通信基本知识

数据通信基本知识 -------------------------------------------------------------------------- 所有计算机之间之间通过计算机网络的通信都涉及由传输介质传输某种形式的数据编码信号。传输介质在计算机、计算机网络设备间起互连和通信作用,为数据信号提供从一个节点传送到另一个节点的物理通路。计算机与计算机网络中采用的传输介质可分为有线和无线传输介质两大类。 一、有线传输介质(Wired Transmission Media) 有线传输介质在数据传输中只作为传输介质,而非信号载体。计算机网络中流行使用的有线传输介质(Wired Transmission Media)为:铜线和玻璃纤维。 1. 铜线 铜线(Copper Wire)由于具有较低的电阻率、价廉和容易安装等优点因而成为最早用于计算机网络中的传输介质,它以介质中传输的电流作为数据信号的载体。为了尽可能减小铜线所传输信号之间的相互干涉(Interference),我们使用两种基本的铜线类型:双绞线和同轴电缆。 (1)双绞线 双绞线(Twisted Pair)是把两条互相绝缘的铜导线纽绞起来组成一条通信线路,它既可减小流过电流所辐射的能量,也可防止来自其他通信线路上信号的干涉。双绞线分屏蔽和无屏蔽两种,其形状结构如图1.1所示。双绞线的线路损耗较大,传输速率低,但价格便宜,容易安装,常用于对通信速率要求不高的网络连接中。 (2)同轴电缆 同轴电缆(Coaxial Cable)由一对同轴导线组成。同轴电缆频带宽,损耗小,具有比双绞线更强的抗干扰能力和更好的传输性能。按特性阻抗值不同,同轴电缆可分为基带(用于传输单路信号)和宽带(用于同时传输多路信号)两种。同轴电缆是目前LAN局域网与有线电视网中普遍采用的比较理想的传输介质。 2.玻璃纤维 目前,在计算机网络中十分流行使用易弯曲的石英玻璃纤维来作为传输介质,它以介质中传输的光波(光脉冲信号)作为信息载体,因此我们又将之称为光导纤维,简称光纤(Optical Fiber)或光缆(Optical Cable)。 光缆由能传导光波的石英玻璃纤维(纤芯),外加包层(硅橡胶)和保护层构成。在光缆一头的发射器使用LED光发射二极管(Light Emitting Diode)或激光(Laser)来发射光脉冲,在光缆另一头的接收器使用光敏半导体管探测光脉冲。 模拟数据通信与数字数据通信 一、通信信道与信道容量(Communication Channel & Channel Capacity) 通信信道(Communication Channel)是数据传输的通路,在计算机网络中信道分为物理信道和逻辑信道。物理信道指用于传输数据信号的物理通路,它由传输介质与有关通信设备组成;逻辑信道指在物理信道的基础上,发送与接收数据信号的双方通过中间结点所实现的逻?quot;联系",由此为传输数据信号形成的逻辑通路。逻辑信道可以是有连接的,也可以是无连接的。物理信道还可根据传输介质的不同而分为有线信道和

巴可放映机报警报错信息处理96940

巴可放映机报警报错信息处理 5004 lamp---no communication 与灯箱无通信检查灯箱是否装好 5005 lamp power supplies, communication failed 与灯电源无通信检查灯电源是否装好5010 pump –refill mode is on 加液模式打开退出加液模式 5011 system running in restricted access mode 系统在警告模式下运行检查输入抽屉与引擎的接触 5042 cold mirror fan—speed too low 冷却镜风扇转速低检查冷却镜风扇是 否接好 5043 cold mirror fan—speed low 冷却镜风扇转速低同上 5052 engine fan –speed too low 引擎风扇转速低检查引擎风扇是否接好 5062 heat exchange fan—speed too low热交换器风扇转速低检查热交换器上方风扇5063 heat exchange fan—speed low 热交换器风扇转速低同上 5072 lamp anode fan –speed too low 灯阳极风扇转速低检查灯阳极风扇是否接好5073 lamp anode fan –speed low 灯阳极风扇转速低检查灯阳极风扇是否接好 5082 lamp cathode fan—speed too low 灯阴极风扇转速低检查灯阴极风扇是否接好5083 lamp cathode fan—speed low 灯阴极风扇转速低检查灯阴极风扇是否接好 5102 SMPS fan 1—speed too low 开关电源风扇1转速检查两个开关电源风扇 5103 SMPS fan 1—speed low 开关电源风扇1转速低检查两个开关电源风扇 5112 SMPS fan 2—speed too low 开关电源风扇2转速低检查两个开关电源风扇 5113 SMPS fan 2—speed low 开关电源风扇2转速低检查两个开关电源风扇 5122 lamp rear fan—speed too low 灯后置风扇转速低检查灯后置风扇是否接好 5123 lamp rear fan—speed low 灯后置风扇转速低检查灯后置风扇是否接好 5132 elca box fan—speed too low 输入-通讯单元风扇转速低检查风扇与导线的连接情况5133 elca box fan—speed low 输入-通讯单元风扇转速低检查风扇与导线的连接情况5160 engine switch—not OK 引擎安装错误检查引擎固定螺丝

数字放映机日常维护和保养

数字放映机日常操作与维护 一、数字放映机操作规范 映前准备 1.对放映室和放映设备表面进行清洁。 2.检查工作环境温度(10-35℃)、供电,排风散热情况。 3.检查设备开机前/后状态、氙灯状况(工作时间、电流、是否闪烁)、光闸。 4.影片内容(服务器)试放。 5.选择影片放映格式、放映检查影像和声音是否正常。 6.检查3D系统设备是否正常。 放映操作和映中巡视 1.按时放映。 2.放映中进行巡视(及时发现异常情况,预防事故)。 如:放映机状态、温度、电压、风扇速度、氙灯 映后整理 1.关闭放映设备,注意散热(10-15分钟)。 2.整理设备(填写工作日志)。 3.盖好机器防尘罩。 二、数字放映机操作流程 开机流程→准备(开启风机)→开启电源→系统自检(LED 灯闪烁)→绿色LED亮(待机状态)→点灯(开启服务器→服务器选择节目)→打开光闸→选择放映模式(服务器播放)→开始放映

关机流程→放映结束→关闭光闸→关闭氙灯(关闭服务器)→等待排风冷却10-15分钟→关闭电源 三、数字放映机日常维护 1.清洁顶部风机口(每周清洁一次)。 2.清洁过滤网和过滤器(每周清洁一次),发现灰尘过多无法清除时请及时更换。 3.清洁氙灯表面灰尘(每周清洁一次)。 4.每日清洁设备底部。 5.每日清洁镜头表面灰尘。 6.每日检查保证液流的气压和冷却液体达标。 7.每日检查电源(电源连接是否稳固、电压是否正常)。 8.每日检查排风(测量排风速度要达标,更换风机后要检查排风方向和速度)。 9.填写好放映日志和检查、维护、故障记录表(检查、维护情况,故障现象、解决办法,温度、风速及氙灯运行等参数)(每月作一次维修记录)。 10.每日放映结束后,要将机器防尘罩盖好。 四、常规状态监控 1.温度(工作环境温度10-35℃)。 2.电压。 3.风扇速度。 4.氙灯运行状况(运行时间、点灯次数、氙灯额定时间)。 5.检查氙灯稳定性(电流、有无闪烁现象)。

通信原理基础知识整理

通信常识:波特率、数据传输速率与带宽的相互关系 【带宽W】 带宽,又叫频宽,是数据的传输能力,指单位时间能够传输的比特数。高带宽意味着高能力。数字设备中带宽用bps(b/s)表示,即每秒最高可以传输的位数。模拟设备中带宽用Hz表示,即每秒传送的信号周期数。通常描述带宽时省略单位,如10M实质是10M b/s。带宽计算公式为:带宽=时钟频率*总线位数/8。电子学上的带宽则指电路可以保持稳定工作的频率围。 【数据传输速率Rb】 数据传输速率,又称比特率,指每秒钟实际传输的比特数,是信息传输速率(传信率)的度量。单位为“比特每秒(bps)”。其计算公式为S=1/T。T为传输1比特数据所花的时间。 【波特率RB】 波特率,又称调制速率、传符号率(符号又称单位码元),指单位时间载波参数变化的次数,可以以波形每秒的振荡数来衡量,是信号传输速率的度量。单位为“波特每秒(Bps)”,不同的调制方法可以在一个码元上负载多个比特信息,所以它与比特率是不同的概念。 【码元速率和信息速率的关系】 码元速率和信息速率的关系式为:Rb=RB*log2 N。其中,N为进制数。对于二进制的信号,码元速率和信息速率在数值上是相等的。 【奈奎斯特定律】 奈奎斯特定律描述了无噪声信道的极限速率与信道带宽的关系。 1924年,奈奎斯特(Nyquist)推导出理想低通信道下的最高码元传输速率公式:理想低通信道下的最高RB = 2W Baud。其中,W为理想低通信道的带宽,单位是赫兹(Hz),即每赫兹带宽的理想低通信道的最高码元传输速率是每秒2个码元。对于理想带通信道的最高码元传输速率则是:理想带通信道的最高RB= W Baud,即每赫兹带宽的理想带通信道的最高码元传输速率是每秒1个码元。 符号率与信道带宽的确切关系为: RB=W(1+α)。 其中,1/1+α为频道利用率,α为低通滤波器的滚降系数,α取值为0时,频带利用率最高,但此时因波形“拖尾”而易造成码间干扰。它的取值一般不小于0.15,以调解频带利用率和波形“拖尾”之间的矛盾。 奈奎斯特定律描述的是无噪声信道的最大数据传输速率(或码元速率)与信道带宽之间的关系。 【香农定理】 香农定理是在研究信号经过一段距离后如何衰减以及一个给定信号能加载多少数据后得到了一个著名的公式,它描述有限带宽、有随机热噪声信道的最大数据传输速率(或码元速率)与信道带宽、信噪比(信号噪声功率比)之间的关系,以比特每秒(bps)的形式给出一个链路速度的上限。

数字放映机使用维护小知识_数字放映出现_摩尔纹_怎么办_陈凡

盘盒的供电线路是专线专用,供电线路接口电压不同,因此严禁硬盘与其他设备混用同一供电线路,乱插则会损坏硬盘。另外存放移动硬盘,应轻拿轻放切忌摔打,放置温度不能过热的区域,尤其要保证移动硬盘不能和带有磁性的物体放在一起,避免移动硬盘磁化,造成数据信息丢失或被破坏,同时还要做好防水防潮等措施。 根据上述排查方法和故障分析,我们得到的启示是当设备发生故障,一般可按下列方法步骤从大到小、由前到后,逐步查找进行急救维护。主要应遵循以下原则:①先软件后硬件;②先周边后主机;③先简单后复杂;④先专用后公用。 只有细化流动放映的操作规程,才能不断提升放映品质、优化放映技术,更好地满足基层官兵的 文化需求。要着力强化影视技术兵的技能素养,对本职工作有一个明确规范,进一步细化标准,使他们熟练掌握设备的性能参数、技术指标和专业知识,避免凭经验、依靠感觉操作和使用保养,甚至疏忽大意造成对设备损坏,发生严重后果。要加强影视技术兵教育管理和培训,熟悉放映设施设备的基本构成、性能及维修保养知识,了解放映设备的安装、运行、使用维护常识,确保在工作中严格遵守放映操作规范,严格遵照放映操作流程开展工作,达到放映安全、可靠、优质。要关注细节、爱护设施、设备,认真做好《放映日志》的填写工作,认真做好岗位安全检查,不断降低故障率,消除安全隐患,杜绝安全事故发生,推动部队文化工程建设上升一个新的台阶。? 数字放映机使用维护小知识———数字放映出现“摩尔纹”怎么办? 有影院客户反馈,我们的放映机出问题了———“放映时画面上有很多水波纹” 。实际上,这是一种数码影像设备中常见的视觉现象。如果物体表面有细密的纹理,常常会出现莫名其妙的水波一样隐约的条纹和奇怪的色彩(见下图),这就是摩尔纹(m oiré) 。数字放映中摩尔纹的产生不是放映机有问题,这种现象是仅当银幕声孔间距、放映机DMD成像分辨率(纵横像素数)及放映距离成一定关系时,在银幕上播放全白图像时会呈现不规则隐约灰色 (或彩色)条纹,在放映影像时则不易察觉。若改变变焦比,改变放映机镜头轴线与银幕的角度,或改变声孔距离,则此摩尔纹会有变化,可以在一定程度上相对改善,但若距离、倾角等条件限制时,此摩尔纹很难消除。所以,可通过改变放映距离、放映机安装位置(向前或向后)、投影角度、移动或绷紧银幕(改变银幕声孔距离)等方法来有效改善或消除此摩尔纹现象。 那现场如何判断是否出现的是摩尔纹呢?可以在播放全白测试图时,拿一张白纸到银幕前,看看白纸上有没有摩尔纹,因为白纸上没有孔阵列,在白纸上是不会呈现摩尔纹的。 还应该注意:有时影厅开空调或暖气引起的气 流也会在银幕上呈现随机变化向上的(像水纹样)气浪纹,这不是摩尔纹,通过关闭空调或暖气,此纹会消失。 中影巴可(北京)电子有限公司 陈 凡 供稿 — 25—现代电影技术 No.7/ 2016 ADVANCED MOTION PICTURE  TECHNOLOGY 放映质量

巴可放映机报警报错信息处理

巴可放映机报警报错信息处理 5003 light sensor - no communication 光线感应器 - 无通讯 5004 lamp---no communication 与灯箱无通信检查灯箱是否装好 5005 lamp power supplies, communication failed 与灯电源无通信检查灯电源线缆是否装好 5010 pump –refill mode is on 加液模式打开退出加液模式 5011 system running in restricted access mode 系统在警告模式下运行检查输入抽 屉与引擎的接触5020重新安装一下控制板的类似手机卡的卡片 5041 cold mirror fan - speed high 冷镜风扇–转速偏高 5042 cold mirror fan—speed too low 冷却镜风扇转速过低检查冷镜风扇及背板 间连线是否接好,是否可以 活动 5043 cold mirror fan—speed low 冷却镜风扇转速低同 上 5050 engine fan - speed too high 引擎风扇转速过高 5051 engine fan - speed high 引擎风扇转速偏高 5052 engine fan –speed too low 引擎风扇转速低检查引擎风扇是否接 好 5053 engine fan - speed low 引擎风扇速度低检查引擎风扇是否接 好,是否可以活动5060 heat exchanger fan - speed too high 热交换器风扇转速过高 5061 heat exchanger fan - speed high 热交换器风扇转速偏高 5062 heat exchange fan—speed too low 热交换器风扇转速过低检查热交换器上方 风扇 5063 heat exchange fan—speed low 热交换器风扇转速偏低同上 5070 lamp anode fan - speed too high 灯阳极风扇转速过高 5071 lamp anode fan - speed high 灯阳极风扇转速偏高 5072 lamp anode fan –speed too low 灯阳极风扇转速低检查灯阳极风扇是否接 好 5073 lamp anode fan –speed low 灯阳极风扇转速低检查灯阳极风扇是否接 好 5080 lamp cathode fan - speed too high 灯阴极风扇转速过高 5081 lamp cathode fan - speed high 灯阴极风扇转速偏高 5082 lamp cathode fan—speed too low 灯风扇控制速度低检查风扇接头和FCB 5083 lamp cathode fan—speed low 灯阴极风扇转速低检查灯阴极风扇是否接 好 5100 smps fan 1 (left side) - speed too high 开关电源风扇1(左侧)转速过高5101 smps fan 1 (left side) - speed high 开关电源风扇1(左侧)转速偏高 5102 SMPS fan 1—speed too low 开关电源风扇1转速过低检查两个开关电源风

HW-T16数字电影放映机用户培训说明材料

HW-T16数字电影放映机用户培训手册

北京海威汇达计算机技术有限责任公司 2007年5月

【目录】 1 开机的基本操作 (3) 2 关机的基本操作 (4) 3待机页面 (5) 4 测试操作 (6) 5 读卡操作 (6) 6 播放操作 (7) 7 设置操作 (10) 8 删除操作 (12) 9 下载操作 (14) 10 增值操作 (17) 11 维护操作 (20) 常见故障 (25)

1 开机的基本操作 用钥匙开侧面板锁,打开HW-T16数字电影放映机侧面板(如下图所示):

◆按下后背板上的电源开关,接通电源; ◆在投影仪调谐区打开投影仪开关; ◆按下操作面板上的启动开关,启动设备,可以看到液晶板显示。(如下图所示) ◆在最下方的滚动条表示设备正在启动,需要等待。该滚动条会循环滚动,直到设备启 动完成,设备启动过程大概需要1~3分钟。 2 关机的基本操作 ◆先关闭投影仪; ◆关闭操作面板上的启动开关,等待操作面板上的音量显示屏灯灭,液晶显示屏上的文字消失,再关闭后背板上的电源开关。 滚动条

3待机页面 设备启动完成之后进入待机页面。(如下图所示) 开机操作完成,液晶控制板显示说明如下: ◆左侧按键对应: 测试:测试各种设备; 读卡:读取影片解码卡信息(可放映影片及相应放映场次); 播放:读取播放影片解码卡中可播放影片; 设置:设置各种设备。 ◆右侧按键对应: 删除:删除数字电影放映机已存储的影片、广告片; 下载:下载发行影片、广告片至播放服务器; 增值:广告管理; 维护:设备各种维护设置。 同时“音量显示屏”会显示影片音频正常输出状态:(显示CF,播放影片时请调节到此状态。数字代表音量大小,通过转动“音量控制旋钮”来调节大小) 可按“声道选择钮”调节“音量显示屏”到麦克输入状态:(显示CH)

多功能一体流动数字电影放映机(便携式)

YS-560DV-3型便携式专用数字放映机 YS-560DV-3便携式一体化流动数字放映系统,是北京尔邦科技有限公司针对中国农村文化市场特点和基层使用习惯开发的便携式多功能一体放映设备。系统包括内置高清硬盘播放机、DVD播放机和卡拉OK功放机的一体化放映机、流动放映银幕、专用机箱、户外电影专用音箱和带可升降功能的放映机支架。全系统标配总重只有30多公斤,主放映机重量仅8公斤左右。 该系统具有采购、运营和维护成本低、操作简单、携带方便、适用性广、可靠性和可维护性强等特点,满足了文化传媒广告单位、流动放映单位、部队、文化科技活动推广站、小型俱乐部、放映厅等对经济型便携数字放映系统的需求,填补了国内空白。通过五年多的市场推广,已被国内许多大型企业、宣传单位和地方放映工作队认可,并已开始批量订购。可以认为,该设备的推广和使用,将在丰富基层农村文化生活,落实和执行“三下乡”的惠农政策中发挥重要作用。 具体特点如下: 1.购置费用超低,性价比极高 流动放映系统主机投入费用低,是目前国内唯一可选的低成本放映器材;作为一款实用和够用的放映设备,使用户低投入和高产出的理想投资设想成为可能; 2.超低运营费用,不增加后期投入 主机的一体化设计,最低可实现单人自行车运送,根本解决了基层流动放映的设备运输问题;现场架设和操作更为简单,整个系统架设和使用操作无需专业人员,三分钟就可完成全部操作培训;所用光源具有寿命长(灯泡寿命3000小时)、这种设计最大限度地降低了用户的人员成本、运输成本; 3.使用灵活、应用广泛 内置一体化的高清硬盘播放器及DVD播放器,可存储上百部标准影片,兼容多种标准清晰度视频格式,可实现极低成本的非商业公益性宣传放映和自娱自乐活动;一机多用的放映模式,最大限度提高设备使用效率,使用户的投资发挥最大效益; 4.系统可靠性和可维护性强 本机的制造商开发和生产投影设备已有近十年历史,并获得3C和CE认证,产品远销全国各省及海外,已拥有近十万用户,产品质量可靠,服务周到,在客户中有着良好的信誉; 主机结构设计中融入DIY理念,用户可自行更换光源、播放机、功放等部件,轻松进行除尘和清洗等保养;对批量采购用户,我们提供免费维修培训,协助用户建立常用零备件库,将售后保障和服务送到你身边; 综合上述,北京尔邦科技有限公司出品的一体化数字放映机,定位准确、定价合理,作为一款实用、够用的多用途流动放映设备,是您投资少,见效快的理想宣传和娱乐工具。 北京尔邦科技有限公司 热线电话:、

放映机知识

1、简述十字车和缺口圆轮的轴、径向间隙的规定及轴、径向间隙不符合要求的影响。 答: 2、为什么遮光器的移动角可以略小于间歇运动装置的工作角? 3、装挂影片时,为什么要留有上、下缓冲弯? 答:为防止片门的间歇运动对还音效果和输片的影响。 4、井冈山2000型放映机画幅调节器的工作原理是怎样的? 当放映出现错格时,转动画幅调节器手柄,使画幅调节器齿轮转动,带动油盒转动,使缺口圆轮绕十字车 5、简答2000型放映机调节画幅错格时,遮光器调节齿轮是怎样和其他相关齿轮配合保持同步运转的。 6、临界闪烁频率与哪些因素有关? 7、简述放映机滑轮旋转的首要条件是什么? 8、放映画面忽实忽虚的主要原因是什么? 9、简答K2000型放映机输片道垂直面的要求及调校步骤。 10、行迹产生的原因是什么?怎样消除全行迹? 答:遮光器与间歇运动装置配合不同步时,会产生行迹。重新调整遮光器可消除行迹。 11、35毫米移动式放映机传动部分和输片部分定期保养有哪些主要内容? 12、曲线式片门有何特点? 13、圆筒形遮光器的遮光特点是什么?

14、简述井冈山2000型放映机十字车间歇运动装置的拆卸步骤和注意事项。 15、XD750-2型氙灯电源中,使用继电器有哪几种?并说明各种继电器的额定电压、吸合电压、释放电压各是多少? 16、氙灯水平使用有何优、缺点? 17、简答放映截幅式宽银幕电影使用短焦距镜头的原因。 18、氙灯光源的基本特点是什么? 19、放映画面局部不清晰的原因是什么,怎样检修? 20、35毫米移动式放映机的光学系统由哪些部分组成,各有何作用? 21、简述放映氙灯对电源的要求。 22、简单概括氙灯内气体放电发光的三个基本过程。 23、2000型放映机电动机虽能启动,但转速低的主要原因是什么? 24、齿轮的模数是如何定义的,它有何作用? 25、简答井冈山2000型放映机传动机构的技术要求有哪些。 26、简答井冈山105型放映机遮光器补偿装置与103A-X2型放映机有何不同,特点是什么? 27、放映机常用的润滑方法有哪几种? 28、简述怎样对激励光刃照度均匀性进行调校。 29、后置机械隙缝式还音光学系统有哪些优点? 30、简述激励光刃的宽度与频率失真的关系。 31、对放映机还音部分有哪些技术要求? 32、简述拆装激励镜头的注意事项。

数字放映机的散热问题真的引起你足够重视了吗

数字放映机的散热问题真的引起你足够重视了吗? 随着数字电影放映机的广泛普及,数字放映机使用的机型和品牌越来越多,设备的新旧程度和使用的年限也都有了较大的差别,所以对数字放映机的维护与保养就显得尤为重要。 一、数字放映机的散热 数字放映机不同于胶片放映机,其集成度高、密封性强、放映机散热困难,而且对放映机散热的要求也高。对数字放映机的散热主要有几个方面: 一是对放映氙灯的散热。放映氙灯功率大、热量高、玻壳薄,灯泡点燃后灯内会产生几十个大气压,如果散热不好,很容易造成炸灯,炸灯不仅使灯泡损坏,而且昂贵的配套反光镜也会坏掉。 二是对DLP芯片的散热。DLP芯片是数字放映机成像的核心部件,属于精密度极高,不能有半点灰尘污染的器件,所以其装配的密封性很好,三片DLP分别装配在三个引擎中,没有任何地方与外界空间直接接触,这就带来严重的散热问题,DLP芯片接收氙灯强光的照射,并将成像的光线反射到银幕上形成高亮度的画面,银幕上放映画面的亮度就靠三片不足两英寸的DLP芯片的反射光确定,芯片的热量会很高,如果对芯片的散热不好,芯片会迅速老化或损坏。 三是对电路的散热。数字放映机的电路集成度高,并处于高热量的放映机壳中,电路工作最怕的就是工作环境温度过高,所以放映机电路也需要很好的散热才能正常工作。 为了解决对上述主要部位的散热,保证各部位都能在正常的环境温度下工作,所以数字放映机对散热问题提出了很高的要求,并采取了很多有效的措施,但这些要求能否实现,不仅靠严格地按照要求安装调试设备,更重要的是靠放映人员平时对放映设备的维护保养。 二、数字放映机的散热途径 1、放映机中的散热通道 放映机设计了严格的散热通道,入风口通过过滤网将外界可能进入放映机内部的灰尘隔离,通过放映机内部的微型排风机将机外凉风吹入,凉风沿散热通道流通,采用风冷方式对放映机的电路、氙灯、引擎等进行散热,最后汇总到放映机的外部抽风系统,将热量排除到室外。 2、强行抽风机(排风)散热 由于放映机内部温度太高,只靠放映机的几个小排风扇无法有效地对放映机内部散热,尤其是放映氙灯产生的高热量,必须有外界强散热措施。数字放映机也采用了胶片机的强排风方式,在放映机房的适当位置加装排风能力较强的轴流风机,对放映机产生的热量和废气进行强力排除,并尽可能将废气和热量排除到室外。数字放映机的散热比胶片机的排风

数据通信基本知识03794

数据通信基本知识 所有计算机之间之间通过计算机网络的通信都涉及由传输介质传输某种形式的数据编码信号。传输介质在计算机、计算机网络设备间起互连和通信作用,为数据信号提供从一个节点传送到另一个节点的物理通路。计算机与计算机网络中采用的传输介质可分为有线和无线传输介质两大类。 一、有线传输介质(Wired Transmission Media) 有线传输介质在数据传输中只作为传输介质,而非信号载体。计算机网络中流行使用的有线传输介质(Wired Transmission Media) 为:铜线和玻璃纤维。 1. 铜线 铜线(Copper Wire)由于具有较低的电阻率、价廉和容易安装等优点因而成为最早用于计算机网络中的传输介质,它以介质中传输的电流作为数据信号的载体。为了尽可能减小铜线所传输信号之间的相互干涉(Interference) ,我们使用两种基本的铜线类型:双绞线和同轴电缆。 (1) 双绞线 双绞线(Twisted Pair) 是把两条互相绝缘的铜导线纽绞起来组成一条通信线路,它既可减小流过电流所辐射的能量,也可防止来自其他通信线路上信号的干涉。双绞线分屏蔽和无屏蔽两种,其形状结构如图 1.1 所示。双绞线的线路损耗较大,传输速率低,但价格便宜,容易安装,常用于对通信速率要求不高的网络连接中。 (2) 同轴电缆 同轴电缆(Coaxial Cable) 由一对同轴导线组成。同轴电缆频带宽,损耗小,具有比双绞线更强的抗干扰能力和更好的传输性能。按特性阻抗值不同,同轴电缆可分为基带(用于传输单路信号)和宽带(用于同时传输多路信号)两种。同轴电缆是目前LAN局域网与有线电视网中普遍采用的比较理想的传输介质。 2. 玻璃纤维目前,在计算机网络中十分流行使用易弯曲的石英玻璃纤维来作为传输介质,它以介质中传输的光波(光脉冲信号)作为信息载体,因此我们又将之称为光导纤维, 简称光纤(Optical Fiber) 或光缆(Optical Cable) 。 光缆由能传导光波的石英玻璃纤维(纤芯),外加包层(硅橡胶)和保护层构成。在光缆一头的发射器使用LED光发射二极管(Light Emitting Diode) 或激光(Laser)来发射光脉冲,在光缆另一头的接收器使用光敏半导体管探测光脉冲。 模拟数据通信与数字数据通信 一、通信信道与信道容量(Communication Channel & Channel Capacity) 通信信道(Communication Channel) 是数据传输的通路,在计算机网络中信道分为物理信道和逻辑信道。物理信道指用于传输数据信号的物理通路,它由传输介质与有关通信设备组成;逻辑信道指在物理信道的基础上,发送与接收数据信号的双方通过中间结点所实现的逻?quot; 联系",由此为传输数据信号形成的逻辑通路。逻辑信道可以是有连接的,也可以是无连接的。物理信道还可根据传输介质的不同而分为有线信道和 无线信道,也可按传输数据类型的不同分为数字信道和模拟信道。信道容量(Channel

电脑连接巴可放映机播放影片操作流程V1.0(0831)

电脑外接巴克放映机 播放高清预告片操作流程V1.0 编写:杨群一.所需硬件和软件 1.硬件: ◆巴克放映机 ◆带有光纤数字音频接口的音频解码器(深圳影城为杜比CP750) ◆电脑(必须带光纤音频输出接口SPDIF) 深圳影城配置为: 显卡支持高清硬件解码(深圳配置:ATI Radeon HD4200) ◆DVI视频线 ◆光纤音频线 2.软件:XP系统或WIN7系统(本文为win7 )和Kmplayer (版本2.9.4.1437) 3.片源:分辨率为1080P(1920*1080)的高清预告片,文件以蓝光原盘、蓝光原盘ISO或Remux 为佳。 根据我方测试,好的高清片源与2K数字电影相比:图像效果无显著性差异,声音效果略差。二.具体操作步骤

1、联接硬件 接放映机的电脑必须要有光纤音频接口(SPDIF),不然实现不了多声道声音输出。 a.集成在电脑主板上的光纤音频接口(SPDIF) 1.电脑接放映机所需线材 a.DVI 视频线 b.光纤音频线

(图左为HDMI转DVI视频线,图右为光纤音频线) (图2 光纤音频线的接口) 注:DVI视频线不能选VGA转DVI接口的线材,因为巴克放映机是不接收模拟信号的。 2.接线 a.放映机端口:DVI端口 b.电脑端口:DVI/HDMI/DISPLAY端口皆可。

以上端口皆可通过相应连接线联接放映机。 c.光纤音频线接杜比音频解码器(以CP750为例) d.光纤音频线接电脑

4.打开放映机启动电脑打开功放 2、软件设置 a.电脑音频输出设置: 右键点击电脑右下角“喇叭”标志,选择“播放设备”,把SPIF设为默认设备。

高清数字电影放映一体机

流动数字电影放映机 山东惠影科技传媒股份有限公司开发出高清视频软件,所生产的数字电影设备获得了广电总局的质量认证,荣获五项国家专利。放映机具有解码能力强,稳定性高,功能丰富等特点,支持电脑,DVD,移动硬盘等多种播放形式;产品具备一系列强大的版权保护和电影播放功能,专业的音视频硬解码技术,超大功率环绕立体声输出,营造真实得数自营影新体验。一体机设计,机身小巧轻便。适应于:流动放映`广告宣传`科普教育`辅助会议。也是丰富基层精神文化生活的新平台。完全符合中国数字电影在农村,社区,部队,学校,家庭等地推广使用,大大降低了客户构建数字影院得成本。 产品特点如下: 1、该系列产品采用了存储、播放、投影、功放等功能于一体的集成化设计,放映主机只需连接音箱,再搭配银幕即可组成一整套放映系统。整套系统全重只有30公斤,主放映机重量仅有7.5公斤,携带方便,操作简单,特别适合于基层单位、厂矿企业和农村的中小型宣传放映使用; 2、该系统使用灵活、应用广泛,内置大容量节目硬盘,可存储几十部高清影片;硬盘采用专利可拔插式设计,无须任何工具,只需开关闸门,即可装入或取出节目盘,轻松便捷; 3、放映机自带USB2.0即插即用高速文件传输接口,用户可轻松导入并可直接通过USB播放,也可自行制作、选择存储和播放节目源。 4、配套使用的美视进口折叠银幕,安装方便、操作灵活,通过转动手轮螺丝,无需工具即可快速搭起或卸下(即使大到200英寸,也只需3分钟)。 数字电影放映机取代传统胶片机已经成为未来发展的趋势。山东惠影科技传媒股份有限公司成功研制出惠影系列数字电影放映机(一体机)。惠影电影放映机是高清数字电影放映机,携带及其方便,更适合流动放映!惠影系列电影放映机,比传统的放映机具有更强劲的优势。 HY330系列数字电影机应用数字微镜开关器件DMD—数字光开关阵列和数字信号处理技术,采用先进的数字光处理技术DLP的数字电影放映新模式,替代了传统电影放映机彩色胶片图像重现模式,实现了无胶片放映。 与传统胶片电影相比,HY330系列数字电影放映机具有色彩鲜明饱满、观影质量稳定、发行成本低廉、发行方式简便、保存简易等显著的技术发行和放映优势,并可有效提供增值服务。 该产品拥有多项的专利技术,具备一系列完善而强大的版权保护和电影播放功能,支持商业影片和公益影片的播放,支持影片放映、片源更新、增值业务等,产品性能卓越,大大降低了客户运营维护成本。 产品优势: 1、自主研发的嵌入式操作系统,操作简单易上手。 2、独有的一体式设计,机身小巧轻便、线条简洁流畅。行李箱式拉杆设计机箱,并可兼做放映台,便于因地制宜开展流动放映。 3、强大的广告放映功能,能够任意设置、插播广告和字幕。 4、标配500G硬盘,可任意添加、删除影片。后面板设有USB2.0高速文件传输、VGA、数字音频等接口,可连接移动硬盘、电脑、DVD等外部设备。 5、输出视频图像清晰度达1920*1080P/60Hz,给您震撼的视觉享受。

数字放映机安装要求(1)

数字放映设备安装要求 为了及时安全的安装贵影院的数字放映设备,影院应按下列做好相应准备。如场地条件未达到安装要求,安装人员可以推迟安装(直到达到要求)。 影院在安装数字放映设备前需要完成以下准备工作: 1、搬运通道及机位空间准备; 通道最窄处应大于102cm,放映间门/楼梯最窄处应大于80cm,转弯处空间130cm。 注:数字放映机最大外包装尺寸和重量如下: DP100/DP90/DP3000 尺寸:140(L) x 100(W) x 118 (H) cm 毛重:164 kg 放映机+底座实际尺寸:120 x 75 x 150 cm,放映机右侧要有>50cm操作空间 DP1500/DP2000 尺寸: 140(L) x 100(W) x 115(H) cm 毛重:120 kg 放映机+底座实际尺寸:102 x 69 x 150 cm 放映机右侧要有>50cm操作空间 2、安装好排风机,数字放映机的排风口外径201mm, DP100/DP3000放映机端风管口处风速>=10-15m/s(5kw-7kw氙灯) DP90/DP1500/DP2000放映机端风管口处风速>=8-12m/s(2kw-4kw氙灯) 影院应准备直径为201mm-203mm的排风软管,并可以延长到放映机安装位置。 3、电源要求: DP100/DP3000:三相五线 (3P+N+PE)380V、7KW、32A、6平方mm多股线,60A空气开关; DP90/DP1500/DP2000 :单相三线(L+N+PE)220V、5KW、26A、4-6平方mm多股线,40A 空气开关。 影院应准备需要延长到放映机的电源线。 4、放映窗口要求:40cm(高) x 50cm (宽),中心离地面高度为120~125cm。由于放映机 高度调整有限,如果窗口中心高度超过125cm,需要考虑地面垫高。另外,窗口两侧面及底面应该有足够的斜度,以保证放映画面无遮挡。放映窗口必须安装光学玻璃,以保证放映质量。如放映机不能放置在中心窗口,则尽量放置在右侧窗口。 5、银幕要求:请影院精确测量屏幕在放映宽银幕格式影片和遮幅格式影片时的宽、高及放 映距离,并将资料填写在《数字放映机安装要求确认表》中。 6、放映间必须安装空调,温度须控制在30 0C以下。 7、还音系统: 请仔细核实音频解码器的品牌与型号,并将资料填写在《数字放映机安装要求确认表》中。 8、地线要求:数字放映机、信号源服务器和音频还音系统应有共同的可靠接地。 9、请影院精确测量音频机柜至放映机的距离,并将资料填写在《数字放映机安装要求确认 表》中。 10、电话线要求:放映间必须安装一条直拨电话线,以供网上维护使用。 11、安装前组织好搬运人力(4-6人)。 12、放映机货到后,氙灯开箱检查,如有破损,要记录和拍照以备索赔。在安装前应将设 备搬运到位。其他货物不要开箱,外包装如有破损,要记录和拍照,等安装技术人员到场开箱验货。 13、放映机工作环境必须清洁,以防影响放映机的图像效果。 特别要注意:幕宽、幕高、放映距离(从银幕到放映机镜头成像面)。若窗口偏离中心线距离较大(>1米)或放映机下倾角大>13度,需要在《数字放映机安装要求确认表》的备注中特殊说明。影院应按照获得设备的型号(DP100/DP90/DP3000/DP2000/DP1500)准备电源及排风系统。 感谢合作!如有问题请及时与巴可公司或授权的经销商联系。

放映基础知识

电影产业—《数字放映知识——基础部分》 一、概念题 1、基础部分: 1)电场中不同两点的电位差称为电压。 2)电场强度的值等于单位正电荷所受的电场力,其方向规定为正电荷的受力方向。 3)在电路中,大小和方向不随时间变化的电流,为直流电流,大小和方向随时间变化的电流,为交流电流,大小随时间变化而方向不变的电流,为脉动电流。 4)单位时间内,电流变化的次数叫做频率。 5)在电阻并联电路中,如某一支路开路,其它支路的电流变大。 6)测量电路中某电阻两端电压时,发现它的电压降升高了,说明可能电源电压升高了、电流增大了或电阻值增大了。 7)电容元件在电路中可以起到传输交流、隔离直流的作用。 8)一个电容器的容量大小,与两极板的面积成正比,与两极板间的距离成反比。 9)电容器串联后,其总容量会减小。电阻并联后,其总阻值会减小。电感器串联后,其总电感量会增大 10)交流电的周期与频率互为倒数关系。 11)交流电的有效值是最大值的0.707倍。 12)三相交流电的线电压大于相电压。

13)在交流电路中,电容器表现的容抗大小与电源的频率有关有关。 14)负载获得最大功率的条件是负载电阻等于电源内阻。 15)节点电流定律说明:电路中流入任何一个节点电流的代数和等于零。或:在任何电路的任何一个节点上,流入节点的电流之和等于流出该节点的电流之和。 16)回路电流定律说明:在电路中,任何时刻,沿任一个闭合回路,电路上各段电压之和等于零。 17)迭加原理只能用于线性电路的分析计算。 18)在磁铁内部,磁力线从 S极到N 极。 19)磁通量的基本单位是安匝。 20)在均匀磁场中,各点磁感应强度大小和方向都是相同的。 21)当自耦变压器的初级绕组匝数等于次级绕组匝数时,负载电流主要取决于电源电流。 22)在广泛使用的三相四线制供电系统中,为了保证安全,应在各个相线上加装保险丝,而不能加在中线上。 23在三相电动机的接线中,任意调换接在电动机上的两根线,都可改变电动机的旋转方向。 24)晶体管包含三个区:集电区,基区和发射区。 25)根据晶体管的工作状态,其输出特性可分为截止区、放大区、饱和区三个区域。

相关主题
文本预览
相关文档 最新文档