当前位置:文档之家› 额定电压0.6-1kV塑料绝缘铜带屏蔽电力电缆技术参数

额定电压0.6-1kV塑料绝缘铜带屏蔽电力电缆技术参数

额定电压0.6-1kV塑料绝缘铜带屏蔽电力电缆技术参数
额定电压0.6-1kV塑料绝缘铜带屏蔽电力电缆技术参数

额定电压0.6/1kV塑料绝缘铜带屏蔽电力电缆

Plastic insulated copper tape screen power cables

with rated voltages 0.6/1kV

一、产品用途Products application

本产品适用于额定电压0.6/1kV及以下输配电线路,具有抗雷击、抗电磁干扰和均衡电位等功能,广泛适用于高层建筑、导弹发射场和精密电子装置集中的场合。

This product is applicable to being fixedly laid on the transmission and distribution line of rated voltage up to 0.6/1.0Kv with the use for power transmission. This product can be used in high-rise building, guided missile lanching site, the place where there are plenty of precise electronic equipments.

二、产品主要技术特点Technique features

本产品具有优越的电气性能、抗雷击、抗电磁干扰和均衡电位耐热性能,易于安装和维护,敷设时不受落差限制。

The product has good performance on electrical characteristic, light-stroke protection, resistance to electromangetic interference, equilibrium voltage, heat resistant.The product characteristic is easy installation and maintaince, especially there is no limit of head drop during the cable laying.

三、产品执行标准Standards

GB/T 12706.1-2002 额定电压1 kV(Um=1.2 kV)到35 kV(Um=40.5 kV)挤包绝缘电力电缆及附件

第1部分:额定电压1kV(Um=1.2 kV)和3 kV(Um=3.6 kV)电缆

Power cables with extruded insulation and their for rated voltages from 1kV(Um=1.2kV)

up to 35kV(Um=40.5kV) Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3

kV(Um=3.6 kV)

IEC 60502-1:1997 额定电压1 kV(Um=1.2 kV)到30 kV(Um=36 kV)挤包绝缘电力电缆及附件

第2部分:额定电压1 kV(Um=1.2kV)和3 kV(Um=3.6kV)电缆

Power cables with extruded insulation and their for rated voltages from 1kV(Um=1.2kV)

up to 35kV(Um=40.5kV) Part 1:Cables for rated voltages of 1kV(Um=1.2kV) and 3 kV

(Um=3.6 kV)

Q/12BJ4973-2002 额定电压0.6/1kV 五芯塑料绝缘电力电缆

Q/12BJ4973-2002 Five cores extruded plastic insulated power cables with rated voltages

0.6/1Kv

Q/12BJ 5142-2003 额定电压0.6/1kV塑料绝缘金属屏蔽电力电缆

Q/12BJ 5142-2003 Plastic insulated copper tape screen power cables with rated voltages 0.6/1kV

GB/T 3956-1997 电缆的导体

GB/T 3956-1997 Conductor of Cables

四、使用特性Operating characteristics

1、额定电压Rated Voltage

电缆额定电压U0/U(U m)为:0.6/1(1.2)kV

Rated V oltage of cable U0/U(U m)::0.6/1(1.2)kV

其中:Notes

U:电缆设计用的导体对地或金属屏蔽之间的额定工频电压;

U:电缆设计用的导体间的额定工频电压;

Rated A.C. V oltage between conductors

U m:设备可承受的“最高系统电压“的最大值。

The maximum system voltage which the equipments can be beared

电缆的额定电压应适合电缆所在系统的运行条件。为了便于选择电缆,将系统划分为下列三类:The rated voltage of cable shall be applicable to system operation condition where the cable lain in. According to cable selecting, the system will be described as 3 types as follow:

——A类:任一相导体与地或接地导体接触时,能在1min内与系统隔离。

When any phase of cable conductor is contacting with earth conductor, the cable will be isolated with the system.

——B类:可在单相接地故障时作短时运行,但任何情况下不宜超过8h,每年接地故障总持续时间不宜超过125h。

The system is allowed to run for 8 hours, when the single-phase earth fault is existing. And the total earth-fault time of 1 year won't be above 125 hours.

——C类:包括不属于A类和B类的系统。

They are including all systems besides A and B.

注:在系统接地故障不能立即自动解除时,故障期间加在电缆绝缘上过高的电场强度,会在一定程度上缩短电缆寿命。如系统预期会经常地运行在持久的接地故障状态下,该系统应划为C类。

When the system earth fault can't be removed automatically, the life of cable will be shortened in some degree because of the over-high electric stess beared by cable insulation.

用于三项系统的电缆,U0的推荐值见表1。

The recommended figure of U0 see the book 1, which are suitalbe for the three systems.

表1 额定电压U0推荐值

Table1 The recommended figure of U0

系统最高电压U m/

kV

The maximum system voltage

额定电压/Kv

Rated Voltage/ kV

A类、B类

System categories A and B

C类

Systems categories C

1.2 0.6 0.6

2、导体额定工作温度The rated temperature of conductor

The maximum assigned temperature of the cable conductor is :XLPE insulated is 90℃, PVC insulated

is70℃.

短路时(最长持续时间不超过5s)电缆导体的最高温度不超过: 交联聚乙烯绝缘250℃, 聚氯乙烯绝缘160℃。

During having a short circuit, lasting less than 5 seconds, the maximum temperature of the cable conductor shall not be above: XLPE insulated is 250℃, PVC insulated is160℃

3、敷设环境温度Ambient temperature for laying

电缆敷设时的环境温度应不低于0℃,否则需要事先预热。

During the cable laying, the ambient temperature must be above 0℃,if not the cable need be preheated.

4、安装弯曲半径The bend radius

安装时电缆最小弯曲半径见表2.

The minimum bending diameter must be above the following standard:

表2 电缆安装时最小弯曲半径

无铠装no amour

有铠装

with amour

无铠装

no amour

有铠装

with amour

安装时的电缆最小弯曲半径

Minimun bend radius of the

cable in course of installation

20D 15D 15D 12D

靠近连接盒和终端的电缆的最

小弯曲半径

The minimun bend radius of the

cable close to the junction box

and terminal

15D 12D 12D 10D

注:D为电缆外径(mm)。Note:D is outer diameter of the cable

5、敷设方式

电缆没有敷设落差限制。There is no limit of head drop during the cable laying.

电缆允许敷设在室内、室外、空气中和土壤中,允许局部有积水。

The cable may be laid in indoor, outdoor, air and soil. The cable may be immersed in water locally.

电缆敷设方式可以是隧道、管道、电缆沟、桥架、排管,铠装电缆允许直埋地下,钢丝铠装电缆允许垂直敷设。

The cable may be laid in tunnel, pipe, trench, conduit and on cable bridge. The amoured cable can be laid undergroud, and the wire- amoured cable can be laid vertically.

单芯电缆不允许敷设在磁性金属管内。

The single core cable mustn't be laid in the magnetic metal pipes.

电缆敷设环境应有良好的散热条件。

The enviroment of cable laying shall be in good heat dissipation condition.

6、电缆敷设时导体最大允许牵引力和电缆最大允许侧压力

The maxium allowed haul-off force and lateral pressure of cable

导体最大允许牵引力计算方法:he calculating method of the maxium allowed haul-off force :

——铜导体:F=70×S(N/mm2)。

——铝导体:F=40×S(N/mm2)。

侧压力计算方法:the calculating method of the maxium allowed lateral pressure:

P=F÷R(N/m),最大允许侧压力不超过3000N/m。the maxium allowed lateral pressure≤3000N/m

式中:F-牵引力,N;lateral pressure

S-导体截面,mm2;conductor section

P-侧压力,N/m;lateral pressure

R-电缆弯曲半径,m。Bend radius

7、电缆运输和保管要求the requirements on transportation and storage:

电缆盘不允许平放。The cable reels shall not be delivered and stored in flat state

运输中严禁从高处扔下装有电缆的电缆盘,严禁机械损伤电缆。It is strictly forbidden to push the cable reel from the high level in order to prevent the cable from damages

电缆如果需要分段使用,电缆分段后必须用防水封帽将电缆头密封,防止进水。

If the cable should be used sectionally, the head of the cable must be sealed in order to prevent water intake.

五、产品表示方法Expressed method of product

1、代号Code

导体代号Conductor code

铝导体aluminium conductor…………………………………………………………………………………L 绝缘代号Insulation code

交联聚乙烯绝缘cross-linking polyethylene(XLPE) insulated……………………………………………YJ 聚氯乙烯绝缘polyvinyl chloride (PVC) insulated……………………………………………V 护套代号1)Sheath code

聚氯乙烯护套polyvinyl chloride and sheath………………………………………………………………V 聚乙烯护套polyethylene sheath……………………………………………………………………………Y 铠装代号Amour code

双钢带铠装steel tape armoured (2)

外护套代号Outer sheath code

聚氯乙烯外护套polyvinyl chloride outer sheath (2)

聚乙烯外护套polyethylene outer sheath (3)

铜带屏蔽copper tape screen………………………………………………………………………………P2 注:Note

1)包括挤包的内衬层和隔离套等。Including the extruding inner covering and separating tape.

2、产品表示方法Expressed method of product

产品用型号(型号中有数字代号的电缆外护层,数字前的文字代号表示内护套)、规格(额定电压、芯数、标称截面)和标准编号表示。

The product is described as type (figure code of cable outer sheath, the word code in front of the figure means inner sheath), specification(rated voltage, cores numbers, sectioal area ) and standards code.

3、产品型号组成The consistant of specifications

产品型号的组成和排列顺序如下:

The consistant of specification, as follow:

外护套 Outer sheath

铠装层 Armourd

内护套 Inner sheath

导体 Conductor

绝缘 Insulation

系列代号 Series code

4、产品表示方法Expressed method of product

示例:铜芯交联聚乙烯绝缘聚氯乙烯护套铜带屏蔽电力电缆,额定电压0.6/1kV,3+1芯,标称截面120mm2,中性线截面70mm2,表示为:

YJVP2-0.6/1 3*120+1*70 Q/12BJ 5142-2003

Example:

Copper conductor XLPE insulated, copper tape screen and PVC sheathed power cables, rated V oltages 0.6/1kV, 3+1 cores, Nominal cross area 120mm2, see the following:

YJVP2-0.6/1 3*120+1*70 Q/12BJ 5142-2003

六、产品型号、规格Types and specifications of products

1、产品型号Type of product

表3产品型号Table 3 Type of product

型号Type

产品名称

Name of product 适用范围及环境Applicability and

urroundings

铜芯Copper core

铝芯Aluminium core

YJVP2 YJLVP2 交联聚乙烯绝缘聚氯乙烯护套铜带屏蔽电力电缆

XLPE insulated PVC sheath copper tape screen power cable

室内、隧道、管道、

电缆沟、桥架、排

管等

In a building, tunnel,

pipe, trench and so on

YJVP2-22 YJLVP2-22 交联聚乙烯绝缘钢带铠装聚氯乙烯护套铜带屏蔽电力电缆XLPE insulated steel tape armoured PVC sheath copper tape screen power cable

VVP2 VLVP2 聚氯乙烯绝缘聚氯乙烯护套铜带屏蔽电力电缆

PVC insulated PVC sheath copper tape screen power cable

室内、隧道、电缆沟

内,或埋地敷设等,

能承受一定机械外

力,但不能承受大的

拉力。For laying

indoors 、in tunnel,

cable trench, or direct

in ground,able to bear

external

mechanicalforces, but

unable to bear large

pulling force

VVP2-22 VLVP2-22 聚氯乙烯绝缘钢带铠装聚氯乙烯护套铜带屏蔽电力电缆

PVC insulated steel tape armoured PVC sheath copper tape screen power cable

2、产品规格Specification of product

For product rated voltage, conductor sectiona and the numbers of cores, please see the table 4.

表4 产品规格

Table 4 Specification of prouduct

型号Type

芯数

Number of cores

标称截面

Nominal cross area(㎜2)

YJVP2 VVP2 YJLVP2

VLVP2

1

1.5-300

2.5-300

YJVP2 YJVP2-22 VVP2 VV2-22

YJLVP2

YJLVP2-22

VLVP2

VLV2-22

2

3

4

5

1.5-300

2.5-300

YJVP2 YJVP2-22 VVP2 VV2-22

YJLVP2

YJLVP2-22

VLVP2

VLV2-22

4-300

YJVP2 YJVP2-22 VVP2 VV2-22

YJLVP2

YJLVP2-22

VLVP2

VLV2-22

3+1

4+1

3+2

4-300

七、产品结构Product structure

1、导体conductor

导体应是符合GB/3956 的第一种或第2种裸退火铜导体或镀金属层退火铜导体,或这两种之一的裸铝导体或铝合金导体;或者第5种裸铜导体或镀金属层退火铜导体。

The conductor shall meet the first one of the requirement of GB/3956 or the second one of that, that is bare anneal copper conductor, or bare aluminium conductor or aluminium alloy, or the fifth one of that, that is bare copper conductor or metal coated anneal copper conductor.

2、绝缘insutation

绝缘应紧密挤包在导体上,且应容易剥离而不损伤绝缘体、导体或镀层。

The insulation layer shall be extruded on the conductor, and it shall be easy to be stripped without damages on insulation, conductor and coating layer.

3、屏蔽Screen

金属屏蔽电缆屏蔽层应选用软铜带,单层重叠绕包。

The screen layer shall be flexible copper tape with single overwrapping type.

4、隔离套(有铠装电缆)Inner sheath(Armoured cables)

采用聚氯乙烯(PVC)或聚乙烯(PE)挤包在缆芯上。

The separated sheath is the extruding PVE or PE on the cable cores

5、铠装Amour

多芯铠装电缆的铠装材料应选用镀锌钢带。

单芯铠装电缆的铠装应选用非磁性材料。根据用户要求可选用不锈钢带、铝带、铝合金带或铜带,如无要求一般应选用不锈钢带。

The amour of the multiple cable shall be zinc-plated steel tape, but the amour of the single cable uesed in AC circuit shall be non-magnetic metal-tape or metal-wire. The tappering mode of metal tape should adopt double layer open tappering, and the mode of metal wire shall mutiple concentric stranding.

注:大量事实证明,采用某种特殊结构铠装(如添加铜丝的隔磁结构)的单芯电缆用于交流回路时均出现电缆发热导致载流量大为下降的现象,所以不推荐采用。

Note: A large number of facts show that the single cable with the special structure amour in the AC circuit exists the heating phenomenon, thus causing the reduction of current capacity. The manufacturer don't suggest to adopt this kind cable.

6、外护套outer sheath

采用ST2型聚氯乙烯护套料或ST7型聚乙烯(PE)护套料挤包在铠装、同心导体上。

The materials of outer sheath are extruding ST2 PVCor ST7 PV on amour, insulation or cable cores.

7、成品电缆的标志Cable marks

成品电缆的外护套表面印有厂名、型号、额定电压、芯数、标称截面和米数的连续标志。

The outer sheath of the cable shall have the following information printed at regular intervals throughtout the length of the cable:

8、产品结构示意图Pictures of products structure

上图电缆型号:YJVP2、YJLVP2、VVP2、VLVP2

Type of above the pictures:YJVP2、YJLVP2、VVP2、VLVP2 1—导体Conductore 4—铜带屏蔽

2—绝缘Insulation 5—护套Sheath

3—包带

上图电缆型号:YJVP2-22、YJLVP2-22、VVP2-22、VLVP2-22

Type of above the pictures:YJVP2-22、YJLVP2-22、VVP2-22、VLVP2-22 1—导体Conductore 5—内衬层Inner covering

2—绝缘Insulation 6—铠装Armor

3—包带7—护套Sheath

八、产品主要技术性能Major technical Characteristics

电缆主要技术性能参数见表5~6。

For the parameters of technical performance index of cables, please see talbe 5-6

表5 电缆通用技术性能参数

Table 5 The parameters of technical performance index of cables

序号

Order

项目Item 单位Unit 指标Indicator

1 导体直流电阻

D.C. resistance of conductor Ω/km

见表6

see addenda A

2 绝缘电阻常数(20℃,最小)

Constant of insulation resistance (20°C,

minimum)

MΩ/km 3.67

3 交流电压试验A.C. voltage test

试验电压test voltage

试验时间test duration

试验结果test result kV

min

3.5

5

绝缘不发生击穿

The insulation shall have no puncture

4 四小时高电压试验

Four-hours high voltage test

试验电压

试验时间

实验结果

kV

h

2.4

4

试样应不击穿The sample shall have no

puncture

5

5.1 5.2 绝缘热延伸试验

insulation thermal elongation test

试验条件test conditions

空气温度air temperature

载荷时间loading time

机械应力mechanical stress

负载下伸长率(最大)

Extensibility on load (max)

冷却后永久伸长率(最大)

Permanent extensibility after being

cooled (max)

min

N/cm2

%

%

200±3

15

20

175

15

表6 导体电阻

Table 6 Resistance of conductor

导体标称截面/mm2 Nominal cross area of conductor/mm2

20℃导体直流电阻≤/Ω/km

Resistance

of conductor in 20℃≤

导体交流电阻/Ω/km

Conductor AC resistance/Ω/km

铜导体

Copper core

铝导体

Aluminium core.

铜导体

Copper core

铝导体

Aluminium core.

4 4.61 7.41 -- -- 6 3.08 4.61 -- -- 10 1.83 3.08 2.333 3.964 16 1.1

5 1.91 1.46

6 2.458 25 0.72

7 1.20 0.927 1.54 35 0.524 0.86

8 0.668 1.11 50 0.387 0.641 0.493 0.822 70 0.268 0.443 0.342 0.568 95 0.193 0.320 0.347 0.411 120 0.153 0.253 0.196 0.325 150 0.124 0.206 0.15

9 0.265 185 0.0991 0.164 0.128 0.211 240 0.0754 0.125 0.0985 0.162 300 0.0601 0.100 0.0797 0.130 400 0.0470 0.0778 0.0640 0.102 500 0.0366 0.0605 0.0504 0.0799 630 0.0283 0.0469 0.0406 0.0634 800 0.0221 0.0367 0.0336 0.0509

表7 电缆电容

Table7 XLPE insulted copper tape screen Capacitance of cable

导体标称截面/ Nominal cross

area of conductor/mm2

每相电容/μ

F/km

Capacitance of

eath phase/μ

F/km

导体标称截面/

Nominal cross

area of

conductor/mm2

每相电容/μ

F/km

Capacitance of

eath phase/μ

F/km

导体标称截面/

Nominal cross

area of

conductor/mm2

每相电容/μ

F/km

Capacitance of

eath phase/μ

F/km

1.5 0.20 35 0.61 185 0.76

2.5 0.24 50 0.63 240 0.82 4 0.29 70 0.69 300 0.86 6 0.34 95 0.80 400 0.88 10 0.47 120 0.82 500 0.93 16 0.57 150 0.78 630 0.98 25 0.53

表8 聚氯乙烯绝缘铜带屏蔽电缆电容

Table 8 PVC insulted copper tape screen Capacitance of cable

导体标称截面/ Nominal cross

area of conductor/mm2

每相电容/μ

F/km

Capacitance of

eath phase/μ

F/km

导体标称截面/

Nominal cross

area of

conductor/mm2

每相电容/μ

F/km

Capacitance of

eath phase/μ

F/km

导体标称截面/

Nominal cross

area of

conductor/mm2

每相电容/μ

F/km

Capacitance of

eath phase/μ

F/km

1.5 0.58 35 1.51 240

2.08

2.5 0.69 50 1.5 300 2.12 4 0.70 70 1.75 400 2.21 6 0.82 95 1.81 500 2.34 10 1.11 120 2.01 630 2.63 16 1.35 150 1.98 800 2.92 25 1.32 185 1.99

表9 交联聚乙烯绝缘电抗

Table 9 XLPE insulted eactanceo f cable (Ω/km)

导体标称截面/ Nominal cross

area of conductor/mm2

电抗/Ω/km Reactance (Ω/km)

YJVP2、YJLVP2

(单芯Sing

core)

YJVP2、YJLVP2

YJVP2-22、

YJLVP2-22、

(两芯Two cores)

YJVP2、YJLVP2

YJVP2-22、

YJLVP2-22、

(三芯、四芯

3core s、4芯)

YJVP2、YJLVP2

YJVP2-22、

YJLVP2-22

(3+1芯、3+1

cores)

YJVP2、YJLVP2

YJVP2-22、

YJLVP2-22

(3+2芯、4+1芯、

5芯、3+2 cores、

4+1cores、5 cores)

1.5 0.122 0.103 0.103 - -

2.5 0.115 0.0957 0.0957 - -

4 0.109 0.0897 0.0897 0.0897 0.0897 6 0.104 0.0850 0.0850 0.0850 0.0850 10 0.101 0.0823 0.0823 0.0823 0.0823 16 0.0978 0.0789 0.0789 0.0789 0.0789 2

5 0.0990 0.0801 0.0801 0.0801 0.0801 35 0.0969 0.0780 0.0780 0.0780 0.0780 50 0.0937 0.0313 0.0313 0.0313 0.0748 70 0.0925 0.0300 0.0300 0.0300 0.073

6 95 0.0908 0.0284 0.0284 0.0284 0.0720 120 0.0898 0.0274 0.0274 0.0274 0.0709 150 0.0903 0.0279 0.0279 0.0279 0.0714 185 0.0905 0.0281 0.0281 0.0281 0.071

7 240 0.0893 - 0.0269 0.0269 0.0704 300 0.0874 - 0.0263 0.0263 0.0699 400 0.0857 - - - - 500 0.0882 - - - - 630 0.0873 - - -

表10 聚氯乙烯绝缘电抗

Table 10 PVC insulted eactanceo f cable (Ω/km)

导体标称截面/ Nominal cross

area of conductor/mm2

电抗/Ω/km Reactance (Ω/km)

VVP2、VLVP2

(单芯Sing

core)

VVP2、VLVP2

VVP2-22

VLVP2-22

(两芯Two

cores)

VVP2、VLVP2

VVP2-22

VLVP2-22

(三芯、四芯

3core s、4芯)

VVP2、VLVP2

VVP2-22

VLVP2-22

(3+1芯、3+1

cores)

VVP2、VLVP2

VVP2-22

VLVP2-22

(3+2芯、4+1芯、

5芯、3+2 cores、

4+1cores、5 cores)

1.5 0.152 0.0108 0.108 - -

2.5 0.136 0.0996 0.0996 - -

4 0.131 0.0992 0.0992 0.0992 0.0992 6 0.126 0.093

5 0.0935 0.0935 0.0935 10 0.114 0.0889 0.0889 0.0889 0.0889 1

6 0.106 0.0844 0.0844 0.0844 0.0844 25 0.10

7 0.084

8 0.0848 0.0848 0.0848 35 0.103 0.0822 0.0822 0.0822 0.0822 50 0.0954 0.0796 0.0796 0.0796 0.0796 70 0.0912 0.0766 0.0766 0.0966 0.0966 95 0.0891 0.0764 0.0764 0.0764 0.0764 120 0.0854 0.0741 0.0741 0.0741 0.0741 150 0.0873 0.0743 0.0743 0.0743 0.0743 185 0.0857 0.0742 0.0742 0.0742 0.0742 240 0.083

9 - 0.0732 0.0732 0.0732 300 0.0834 - 0.0729 0.0729 0.0729 400 0.0816 - -

500 0.0803 - -

630 0.0781 - -

800 0.0755 - -

表11 无铠装电缆载流量

Table 11 Current carrying of Unarmored cable 适用电缆型号:YJVP2、YJLVP2

Applicable cable types: YJVP2、YJLVP2

导体最高允许工作温度:90℃

The maximum assigned temperature of the conductor is90℃.

环境温度:25℃

Ambient temperature:25℃

土壤热阻系数:120℃·cm/W

Soil thermal resistivity 120℃·cm/W

导体

截面

mm2 Conductor cross area

mm2

空气中敷设长期连续负荷允许载流量(A)

Laying long-term continuous load allowable current-carrying

capacity in the air (A)

直埋敷设长期连续负荷允许载流量(A)

Direct-buried laying long-term continuous load allowable

current-carrying capacity (A)铜芯Copper core 铝芯Aluminium core. 铜芯Copper core 铝芯Aluminium core.

单芯

Single-

core

二芯

2-cores

三芯

3-cores

四芯

4-cores

单芯

Single-

core

二芯

2-cores

三芯

3-cores

四芯

4-cores

单芯

Single-

core

二芯

2-cores

三芯

3-cores

四芯

4-cores

单芯

Single-

core

二芯

2-cores

三芯

3-cores

四芯

4-cores

1.5 27.6 2

2.8 19.2 23 -- -- -- -- 37.2 28.8 24 -- -- -- -- --

2.5 38.4 31.2 26.4 35 28.8 24 19.2 26 50.4 38.4 32.4 33 38.4 28.8 24 25 4 49.2 42 34.8 34.8 37.2 31.2 26.4 26.4 67.2 49.2 42 42 51.6 38.4 32.4 32.4 6 64.8 52.8 45.6 45.6 49.2 40.8 34.8 34.8 84 62.4 52.8 52.8 64.8 48 40.8 40.8 10 86.4 72 62.4 61.2 66 55.2 48 48 112.8 82.8 70.8 69.2 86.4 6

3.6 55.2 54 16 116.4 9

4.8 82.8 81.6 88.8 73.2 63.6 63.6 148.8 109.2 92.4 91.2 114 84 70.8 69.6 25 146.4 128.4 111.6 110.4 122.4 99.6 86.4 8

5.2 195.6 141.6 121.2 120 150 109.2 93.6 92.4 35 194.4 148.8 135.6 138 148.8 114 104.4 10

6.8 235.2 166.8 148.8 14

7.6 181.2 12

8.4 114 114 50 244.8 186 168 172.8 188.4 144 12

9.6 133.2 289.2 205.2 180 182.4 222 158.4 139.2 140.4 70 303.6 235.2 210 213.6 234 181.2 162 163.2 350.4 249.6 220.8 219.6 270 192 169.2 168 95 326.4 285.6 256.8 261.6 256.8 218.4 198 201.6 417.6 308.4 261.6 261.6 320.4 229.2 201.6 200.4 120 427.2 327.6 296.4 302.4 331.2 253.2 229.2 234 470.4 338.4 296.4 297.6 366 261.6 228 230.4 150 492 378 351.6 356.4 379.2 290.4 270 273.6 536.4 386.4 339.6 343.2 411.6 297.6 261.6 264 185 558 400 398.4 409.2 429.6 322 308.4 315.6 600 386 381.6 385.2 462 340 296.4 297.6 240 662.4 479 396 396 510 383 367.2 355.2 698.4 446 441.6 398 536.4 400 340.8 327.6 300 763.2 522 452 457 588 487 361 348 792 507 430 430 600 510 430 450 400 908.4 -- -- -- 706.8 -- -- -- 927.6 -- -- -- 711.6 -- -- -- 500 1063.2 -- -- -- 816 -- -- -- 1051.2 -- -- -- 804 -- -- -- 630 1230 -- -- -- 944.4 -- -- -- 1200 -- -- -- 920.4 -- -- --

表12 铠装电缆载流量

Table 12 Current carrying of armored cable 适用电缆型号:YJVP2-22、YJLVP2-22

Applicable cable types: YJVP2-22、YJLVP2-22

导体最高允许工作温度:90℃

The maximum assigned temperature of the conductor is90℃.

环境温度:25℃

Ambient temperature:25℃

土壤热阻系数:120℃·cm/W

Soil thermal resistivity 120℃·cm/W

导体截面mm2 Conduct or cross area mm2

空气中敷设长期连续负荷允许载流量(A)

Laying long-term continuous load allowable

current-carrying capacity in the air (A)

直埋敷设长期连续负荷允许载流量(A)

Direct-buried laying long-term continuous load

allowable current-carrying capacity (A)铜芯Copper core 铝芯Aluminium core. 铜芯Copper core 铝芯Aluminium core. 二芯

2-cores

三芯

3-cores

四芯

4-cores

二芯

2-cores

三芯

3-cores

四芯

4-cores

二芯

2-cores

三芯

3-cores

四芯

4-cores

二芯

2-cores

三芯

3-cores

四芯

4-cores

4 43.2 37.2 36 32.4 27.6 27.6 49.2 42 40.8 38.4 32.4 31.2 6 54 46.8 46.8 42 36 36 62.4 54 52.8 48 40.8 40.8 10 72 62.4 62.4 55.2 48 48 80.4 70.8 69.2 62.4 55.2 54 16 97.2 85.2 84 74.4 64.8 64.8 108 93.6 92.4 84 72 70.8 2

5 127.2 115.2 112.8 97.2 87.

6 87.6 141.6 123.6 120 109.2 94.8 92.4 35 153.6 136.8 142.8 118.8 105.6 110.4 168 147.6 151.2 129.6 112.8 116.4 50 192 172.8 178.8 147.6 133.2 138 205.2 181.2 184.8 158.4 139.2 141.6 70 236.4 214.8 220.8 182.4 165.6 169.2 248.4 230.4 222 192 170.4 170.4 95 288 260.4 271.2 222 200.4 208.8 297.6 259.2 265.2 229.2 199.2 205.2 120 333.6 302.4 312 258 232.8 241.2 340.8 296.4 302.4 262.8 228 232.8 150 382.8 350.4 361.2 295.2 270 277.2 384 338.4 340.8 295.2 259.2 261.6 185 400 339 339 322 262 265 420 420 420 300 275 275 240 479 396 396 383 309 309 500 500 500 340 320 320

表13 无铠装电缆载流量

Table 13 Current carrying of Unarmored cable 适用电缆型号:VVP2、VLVP2

Applicable cable types: VVP2、VLVP2

导体最高允许工作温度:70℃

The maximum assigned temperature of the conductor is70℃.

环境温度:25℃

Ambient temperature:25℃

土壤热阻系数:120℃·cm/W

Soil thermal resistivity 120℃·cm/W

截面mm2 Conduct or cross area mm2

空气中敷设长期连续负荷允许载流量(A)

Laying long-term continuous load allowable

current-carrying capacity in the air (A)

直埋敷设长期连续负荷允许载流量(A)

Direct-buried laying long-term continuous load

allowable current-carrying capacity (A)铜芯Copper core 铝芯Aluminium core. 铜芯Copper core 铝芯Aluminium core. 单芯

Single

-core

二芯

2-core

s

三芯

3-core

s

四芯

4-core

s

单芯

Single

-core

二芯

2-core

s

三芯

3-core

s

四芯

4-core

s

单芯

Single

-core

二芯

2-core

s

三芯

3-core

s

四芯

4-core

s

单芯

Single

-core

二芯

2-core

s

三芯

3-core

s

四芯

4-core

s

1.5 23 19 16 15 —31 24 20 22

2.5 32 26 22 19 24 20 16 15 42 32 27 29 32 24 20 25 4 41 35 29 29 31 26 22 22 56 41 35 35 43 32 27 27 6 54 44 38 38 41 34 29 29 70 52 44 44 54 40 34 34 10 72 60 52 51 55 46 40 40 94 69 59 58 72 53 46 45 16 97 79 69 68 74 61 53 53 124 91 77 76 95 70 59 58 25 122 107 93 92 102 83 72 71 163 118 101 100 125 91 78 77 35 162 124 113 115 124 95 87 89 196 139 124 123 151 107 95 95 50 204 155 140 144 157 120 108 111 241 171 150 152 185 132 116 117 70 253 196 175 178 195 151 135 136 292 208 184 183 225 160 141 140 95 272 238 214 218 214 182 165 168 348 257 218 218 267 191 168 167 120 356 273 247 252 276 211 191 195 392 282 247 248 305 218 190 192 150 410 315 293 297 316 242 225 228 447 322 283 286 343 248 218 220 185 465 320 332 341 358 251 257 263 500 395 318 321 385 310 247 248 240 552 -- 396 -- 425 -- 306 -- 582 -- 368 -- 447 -- 284 -- 300 636 -- -- -- 490 -- -- -- 660 -- -- -- 500 -- -- -- 400 757 -- -- -- 589 -- -- -- 773 -- -- -- 593 -- -- --

630 1025 -- -- -- 787 -- -- -- 1000 -- -- -- 767 -- -- -- 800 1338 -- -- -- 934 -- -- -- 1153 -- -- -- 885 -- -- --

表14 铠装电缆载流量

Table 14 Current carrying of armored cable

适用电缆型号:VVP2-22、VLVP2-22

Applicable cable types: VVP2-22、VLVP2-22

导体最高允许工作温度:70℃

The maximum assigned temperature of the conductor is70℃.

环境温度:25℃

Ambient temperature:25℃

土壤热阻系数:120℃·cm/W

Soil thermal resistivity 120℃·cm/W

截面mm2 Conduct or cross area mm2

空气中敷设长期连续负荷允许载流量(A)

Laying long-term continuous load allowable

current-carrying capacity in the air (A)

直埋敷设长期连续负荷允许载流量(A)

Direct-buried laying long-term continuous load

allowable current-carrying capacity (A)铜芯Copper core 铝芯Aluminium core. 铜芯Copper core 铝芯Aluminium core. 二芯

2-cores

三芯

3-cores

四芯

4-cores

二芯

2-cores

三芯

3-cores

四芯

4-cores

二芯

2-cores

三芯

3-cores

四芯

4-cores

二芯

2-cores

三芯

3-cores

四芯

4-cores

4 36 31 30 27 23 23 41 3

5 34 32 27 26

6 45 39 39 35 30 30 52 45 44 40 34 34

10 60 52 52 46 40 40 67 59 58 52 46 45

16 81 71 70 62 54 54 90 78 77 70 60 59

25 106 96 94 81 73 73 118 103 100 91 79 77

35 128 114 119 99 88 92 140 123 126 108 94 97

50 160 144 149 123 111 115 171 151 154 132 116 118

70 197 179 184 152 138 141 207 192 185 160 142 142

95 240 217 226 185 167 174 248 216 221 191 166 171 120 278 252 260 215 194 201 284 247 252 219 190 194 150 319 292 301 246 225 231 320 282 284 246 216 218 185 326 333 345 251 257 266 395 315 319 310 242 246 240 -- 392 -- -- 305 -- -- 364 -- -- 295 --

不同土壤温度下载流量的修正系数

Current rating for variation in soil temperature

土壤温度Soil temperature

20 ℃25 ℃30 ℃35 ℃40 ℃

修正系数Rating factor

1.04 1.0 0.96 0.92 0.87

九、结构尺寸Configuration Measurements

电缆的结构尺寸见表15~表30。

Configuration measurements of the cable,see the table15~ table30

表15 0.6/1kV交联聚乙烯绝缘铜带屏蔽电力电缆

Table15 XLPE insulated copper tape screen power cables with rated voltages 0.6/1kV

芯数及标称截面Number of cores and Nominal cross area

(mm2)

无铠装Unarmored 铠装Armored

计算外径

Calculated

external

diameter

(mm)

计算重量Calculated

weight (kg/km)

计算外径

Calculated

external

diameter

(mm)

计算重量Calculated

weight (kg/km)

YJVP2 YJLVP2 YJVP2-22 YJLVP2-22

1*6 7.1 106 68 - - - 1*10 8.3 153 91 12.2 276 215 1*16 9.5 213 118 13.3 350 255 1*25 11.1 315 164 15.0 473 322 1*35 11.8 406 196 15.6 572 362 1*50 13.3 533 248 17.1 717 432 1*70 15.1 739 327 18.9 946 533 1*95 16.8 991 419 20.5 1213 641 1*120 18.5 1235 512 22.1 1471 749 1*150 20.6 1514 625 24.1 1769 879 1*185 22.7 1877 765 26.0 2143 1031 1*240 25.3 2430 967 28.6 2723 1261 1*300 27.9 3016 1181 31.1 3338 1503 1*400 31.6 3986 1566 34.7 4345 1925

Table16 XLPE insulated copper tape screen power cables with rated voltages 0.6/1kV

表17 0.6/1kV 交联聚乙烯绝缘铜带屏蔽电力电缆

Table17 XLPE insulated copper tape screen power cables with rated voltages 0.6/1kV

芯数及标称截面 Number of cores and Nominal cross area (mm 2) 无铠装Unarmored

铠装Armored

计算外径 Calculated external

diameter

(mm)

计算重量 Calculated

weight (kg/km) 计算外径 Calculated external

diameter (mm) 计算重量 Calculated weight (kg/km) YJVP2

YJLVP2

YJVP2-22 YJLVP2-22 2*2.5 10.5 151 120 13.7 275 244 2*4 11.4 194 144 14.6 328 278 2*6 12.5 248 173 15.7 393 318 2*10 14.9 361 238 18.1 532 409 2*16 17.2 503 312 20.4 697 507 2*25 20.5 718 414 23.7 947 643 2*35 21.8 934 512 25.0 1177 755 2*50 19.2 1082 509 22.4 1298 726 2*70 21.8 1499 671 25.2 1752 924 2*95 24.7 2014 866 28.0 2298 1149 2*120 27.3 2511 1060 31.9 2821 1371 2*150 30.7 3129 1343 35.5 3485 1699 2*185

33.9

3877

1644

38.9

4652

2419

Number of cores and Nominal cross area

(mm2) 计算外径

Calculated

external

diameter

(mm)

计算重量Calculated

weight (kg/km)

计算外径

Calculated

external

diameter

(mm)

计算重量Calculated

weight (kg/km) YJVP2 YJLVP2 YJVP2-22 YJLVP2-22

3*2.5 10.9 187 140 14.3 318 271 3*4 11.8 241 166 15.2 381 305 3*6 13.1 317 205 16.3 469 356 3*10 15.8 484 300 19.0 664 480 3*16 18.2 660 375 21.4 865 579 3*25 21.7 991 534 24.9 1233 777 3*35 23.1 1269 636 26.2 1521 888 3*50 24.0 1589 730 27.4 1866 1008 3*70 27.1 2212 970 30.5 2523 1281 3*95 31.1 3027 1304 35.7 3720 1997 3*120 34.4 3769 1593 39.1 4540 2365 3*150 36.9 4603 1924 41.8 5440 2761 3*185 41.0 5712 2362 46.1 6652 3303 3*240 45.8 7397 2992 51.1 8459 4054 3*300 50.6 9176 3649 56.1 10363 4836

表18 0.6/1kV交联聚乙烯绝缘铜带屏蔽电力电缆

Number of cores and Nominal cross area

(mm2) 计算外径

Calculated

external

diameter

(mm)

计算重量Calculated

weight (kg/km)

计算外径

Calculated

external

diameter

(mm)

计算重量Calculated

weight (kg/km)

YJVP2 YJLVP2 YJVP2-22 YJLVP2-22

4*2.5 11.7 228 166 15.0 366 303 4*4 12.8 298 198 16.1 448 348 4*6 14.0 399 249 17.4 562 412 4*10 17.0 592 346 20.4 786 540 4*16 19.7 847 466 23.0 1021 640 4*25 23.7 1249 671 27.0 1465 857 4*35 25.2 1568 803 28.7 1854 1009 4*50 25.9 2071 926 29.4 2371 1226 4*70 29.9 2946 1290 34.8 3618 1963 4*95 33.3 3955 1659 38.3 4710 2413 4*120 36.4 4928 2027 41.6 5761 2860 5*150 40.7 6056 2484 46.1 6994 3422 4*185 46.3 7541 3075 51.9 8619 4153 4*240 50.9 9758 3884 56.7 10962 5088 4*300 55.6 12085 4716 61.7 13418 6049

表19 0.6/1kV 交联聚乙烯绝缘铜带屏蔽电力电缆

Table19 XLPE insulated copper tape screen power cables with rated voltages 0.6/1kV

表20 0.6/1kV 交联聚乙烯绝缘铜带屏蔽电力电缆

芯数及标称截面 Number of cores and Nominal cross area (mm 2) 无铠装Unarmored

铠装Armored

计算外径 Calculated external

diameter

(mm)

计算重量 Calculated weight (kg/km) 计算外径 Calculated external

diameter (mm) 计算重量 Calculated

weight (kg/km) YJVP2

YJLVP2 YJVP2-22 YJLVP2-22 5*1.5 11.7 207 160 14.9 310 296 5*2.5 12.7 268 190 15.9 379 338 5*4 14.0 355 229 17.2 474 390 5*6 15.4 478 290 18.6 607 466 5*10 18.7 707 400 21.9 859 611 5*16 21.7 995 519 24.9 1168 762 5*25 26.2 1503 742 29.4 1709 1034 5*35

28.0

1965

910

31.3

2194

1231

常见电缆型号说明及用途

常见电缆型号说明及用途 型号名称用途 铜芯 NA-YJV,NB-YJV,交联聚乙烯绝缘聚氯乙烯护套A(B)类耐火电力电缆可敷设在对耐火有要求的室内、隧道及管道中。 NA-YJV22, NB-YJV22,交联聚乙烯绝缘钢带铠装聚氯乙烯护套A(B)类耐火电力电缆适宜对耐火有要求时埋地敷设,不适宜管道内敷设。 NA-VV,NB-VV,聚氯乙烯绝缘聚氯乙烯护套A(B)类耐火电力电缆可敷设在对耐火有要求的室内、隧道及管道中。 NA-VV22,NB-VV22,聚氯乙烯绝缘钢带铠装聚氯乙烯护套A(B)类耐火电力电缆适宜对耐火有要求时埋地敷设,不适宜管道内敷设。 WDNA-YJY,WDNB-YJY,交联聚乙烯绝缘聚烯烃护套A(B)类无卤低烟耐火电力电缆可敷设在对无卤低烟且耐火有要求的室内、隧道及管道中。 WDNA-YJY23,WDNB-YJY23,交联聚乙烯绝缘钢带铠装聚烯烃护套A(B)类无卤低烟耐火电力电缆适宜对无卤低烟且耐火有要求时埋地敷设,不适宜管道内敷设。 常见型号名称用途 铜芯铝芯 ZA-YJV,ZA-YJLV,ZB-YJV,ZB-YJLV,ZC-YJV,ZC-YJLV,交联聚乙烯绝缘聚氯乙烯护套A(B、C)类阻燃电力电缆可敷设在对阻燃有要求的室内、隧道及管道中。 ZA-YJV22,ZA-YJLV22,ZB-YJV22,ZB-YJLV22,ZC-YJV22,ZC-YJLV22,交联聚乙烯绝缘钢带铠装聚氯乙烯护套A(B、C)类阻燃电力电缆适宜对阻燃有要求时埋地敷设,不适宜管道内敷设。 ZA-VV,ZA-VLV,ZB-VV,ZB-VLV,ZC-VV,ZC-VLV,聚氯乙烯绝缘聚氯乙烯护套A(B、C)类阻燃电力电缆可敷设在对阻燃有要求的室内、隧道及管道中。 ZA-VV22,ZA-VLV22,ZB-VV22,ZB-VLV22,ZC-VV22,ZC-VLV22,聚氯乙烯绝缘钢带铠装聚氯乙烯护套A(B、C)类阻燃电力电缆适宜对阻燃有要求时埋地敷设,不适宜管道内敷设。 WDZA-YJY,WDZA-YJLY,WDZB-YJY,WDZB-YJLY,WDZC-YJY,WDZC-YJLY,交联聚乙烯绝缘聚烯烃护套A(B、C)类阻燃电力电缆可敷设在对阻燃且无卤低烟有要求的室内、隧道及管道中。 WDZA-YJY23,WDZA-YJLY23,WDZB-YJY23,WDZB-YJLY23 ,WDZC-YJY23,WDZC-YJLY23, 交联聚乙烯绝缘钢带铠装聚烯烃护套A(B、C)类阻燃电力电缆适宜对阻燃且无卤低烟有要求时埋地敷设,不适宜管道内敷设。 电缆名称用途 VV、VLV, 铜(铝)芯聚氯乙烯绝缘聚氯乙烯护套电力电缆敷设在室内、隧道及管道中或户外托架敷设,不承受压力和机械外力 VY、VLY ,铜(铝)芯聚氯乙烯绝缘聚乙烯护套电力电缆

聚氯乙烯绝缘护套电力电缆

聚氯乙烯绝缘护套电力电缆 型号名称适用范围 VVVLV 聚氯乙烯绝缘聚氯乙烯护套电力电缆敷设在室内、隧道及管道中,电缆不能承受压力和机械外力作用。 VV22VLV22 聚氯乙烯绝缘钢带铠装聚氯乙烯护套电力电缆敷设在室内、隧道及直埋土壤中,电缆能承受压力和其他外力作用。 VV32VLV32 聚氯乙烯绝缘细钢丝铠装聚氯乙烯护套电力电缆敷设在室内、矿井中,水中,电缆能承受相当的拉力。 VV42VLV42 聚氯乙烯绝缘粗钢丝铠装聚氯乙烯护套电力电缆敷设在竖井、水下等垂直场合,能承受相当的轴向拉力。 ZR-VVZR-VLV 聚氯乙烯绝缘聚氯乙烯护套阻燃电力电缆敷设在室内、隧道及管道中,电缆不能承受压力和机械外力作用。 ZR-VV22ZR-VLV22 聚氯乙烯绝缘钢带铠装聚氯乙烯护套阻燃电力电缆敷设在室内、隧道及直埋土壤中,电缆能承受压力和其他外力作用。 ZR-VV32ZR-VLV32 聚氯乙烯绝缘细钢丝铠装聚氯乙烯护套阻燃电力电缆敷设在室内、矿井中,水中,电缆能承受相当的拉力。 ZR-VV42ZR-VLV42 聚氯乙烯绝缘粗钢丝铠装聚氯乙烯护套阻燃电力电缆敷设在竖井,水下等垂直场合,能承受上相当的轴向拉力。 聚氯乙烯绝缘护套耐火电力电缆 型号及名称 型号名称 NH-VV 聚氯乙烯绝缘和护套耐火电力电缆 NH-VV22 聚氯乙烯绝缘和护套钢带铠装耐火电力电缆 交联聚乙烯绝缘电力电缆 型号及名称 型号名称 YJV YJLV 铜芯或铝芯交联聚乙烯绝缘,聚氯乙烯护套电力电缆 YJV22 YJLV22 铜芯或铝芯交联聚乙烯绝缘,钢带铠装聚氯乙烯护套电力电缆 YJV32、42 YJLV32、42 铜芯或铝芯交联聚乙烯绝缘,钢丝铠装聚氯乙烯护套电力电缆 编辑本段代号及其含义 1.绝缘种类:V代表聚氯乙稀;X代表橡胶;Y代表聚乙烯;YJ代表交联聚乙烯;Z代表纸。 2.导体材料:L代表铝;T(省略)代表铜。

电力电缆金属护套或屏蔽的接地作用

电力电缆金属护套或屏蔽的接地作用 1.概述 接地用以:防止人身受到电击,确保电力系统正常运行,保护线路和设备免遭损坏,还可防止电气火灾,防止雷击和静电危害等。 电缆金属护套或屏蔽的接地的作用有: (1)电缆线芯双屏蔽和金属护套的电容电流有一回路流入大地; (2)当电缆对金属护套或屏蔽发生短路时,短路电流可流入地下; (3)电缆线芯绝缘损伤后发生相间短路发展至接地故障时,故障电流通过接地线流入地中; (4)电缆中的不平衡电流引起的感应电压、通过地线与大地形成短路,防止电缆对接地支架存在电位差而放电闪络。 现在大量使用的交联电缆,分相屏蔽,屏蔽层分金属(铜带)层和半导电层。半导电层中含有胶质碳,可起到均匀电场的作用;同时碳能吸收电缆本体细小间隙中因空气电离产生的败坏物,均匀电场,以保护电缆绝缘。 金属屏蔽层的作用: 第一:保持零电位,使缆芯之间没有电位差; 第二:在短路时承载短路电流,以免因短路引起电缆温升过高而损坏绝缘层,同时屏蔽层也可以防止周围外界强电场对电缆内传输电流的干扰; 第三:屏蔽层可以有效地将电缆产生的强电场限制在屏蔽层内,由于屏蔽层接地,外部便不存在电缆产生的强电场,不会对周围的弱电线路及仪表,产生强电干扰 或危及人身安全。 在配电系统中:电源电缆的起始端与发电厂的接地网接通,末端与变电所接地网连通;变电所馈出电缆接地与各用户连通;低压电缆的PEN线与电缆铠甲接地后可与高压电缆接地等电位;重要用户的电源电缆又来自独立的电源。这样,高低压电缆接地线的互相联结,又与接地网连在一起。因此,电缆接地成了接地系统总体的重要组成部分,对电网安全运行有重要作用。 3.2保证接地线截面和质量 交联电缆接头制作中,铜屏蔽层、铠甲层应分别连接不得中断,两者还应加以绝缘分隔,恢复铜屏蔽应采用软质铜编织线连接;确保与各相绝缘外屏蔽接触良好。两端与铜屏蔽层焊接,铠甲用镀锡地线恢复跨接,分别焊在两边的铠甲上。 电缆接地线的规格,严格要求应按电缆线路的接地电流大小而定。但在实际施工中,往往缺乏这方面的资料, 一般120㎜2以下电缆选用16 m㎡铜线; 150㎜2~240㎜2电缆选用25 m㎡铜线; 300 ㎜2以上电缆接地线不应小于35㎜2; 橡塑电缆的接地线必须采用镀锡软铜编织线。接地线与铜屏蔽层和金属护套焊接工艺、焊接面积均应符合要求。电缆接地线应直接接于接地网,不得串接,接地线必须压接的接线端子,以保证连接可靠及检测拆卸方便。 美国3M公司的游丝卡紧法和法国梅兰日兰公司的卡扣捆扎法,不仅能方便可靠地进行接地连接,而且还能避免烙铁灼伤电缆绝缘的危险,值得借鉴。

常用的几种电线电缆绝缘材料

常用的几种电线电缆绝 缘材料 Pleasure Group Office【T985AB-B866SYT-B182C-BS682T-STT18】

常用的几种电线电缆绝缘材料 绝缘层与保护层、屏蔽层、护套层、导体线芯一样,是构成电线电缆必须的基本构件。它确保导体线芯传输的电流或电磁波、光波只沿着导线行进而不流向外面,同时也确保外界物体和人身的安全。今天的电线电缆绝缘材料中,塑料和橡胶两大类有面高分子材料已占主导材料,衍生出类型繁多的适用于不同用途和环境要求的电线电缆产品。 下面介绍生产生活中最常用的几类电线电缆绝缘材料 第一类聚氯乙烯(PVC)料 聚氯乙烯塑料价格便宜,特理机械性能较好,挤出工艺简单,比重轻,耐油和耐腐蚀好。同时,氯乙烯(PVC)性能参数一般,多用来制造1KV及以下的低压电线电缆。采用添加了电压稳定剂的聚氯乙烯(PVC)绝缘料,允许生产6KV级电缆。 聚氯乙烯(PVC)有一定阻燃料,但燃烧时会释放一毒烟气,不宜用于着火燃烧时需要满足低烟、低毒要求的场合。同时聚氯乙烯(PVC)线缆也不适用在含有苯及苯胺类、酮类、吡啶、甲醇、乙醇、乙醛化学剂土质中,不宜用在含有三氯乙烯、三氯甲烷、四氯化碳、二硫化碳、冰醋酸环境中。 第二类:交联聚乙烯(XLPE) 交联聚乙烯(XLPE)电绝缘性能优越,经过高分子交联后成为热固性材料,机械性能和耐热性好。已成为中、高压电力电缆的主导品种。交联聚乙烯(XLPE)也具有结构简单,制造方便,比重轻,敷设方便、耐腐蚀、做终端和中间接头简单。 交联聚乙烯(XLPE)不含卤素,不阻燃,燃烧时不会产生大量毒气及烟雾,若添加阻燃剂,会使机械性能及电气性能下降。交联聚乙烯(XLPE)对紫外线照射敏感。 第三类氟塑料 氟塑料突出特点是电绝缘性能优异,适合高频信号传输,耐高温,可提高载流量,阻燃性好,氧指数高,燃烧时火焰扩散范围小,产生的烟雾量少,还具有优良的耐气候老化性能和机械强度,不受各种酸、碱和有机溶剂影响。但其比重大,价格昂贵,氟塑料主要用于耐高温场合。 第四类橡皮料

(完整版)常用电力电缆规格型号

聚氯乙烯绝缘聚氯乙烯护套电力电缆 1、用途:本产品适用于交流50HZ,额定电压0.6/1KV的线路中,供输配电能之用。 2、产品标准:GB12706·2-91额定电压35KV及以下铜芯、铝芯塑料绝缘电力电缆、聚氯乙烯绝缘电力电缆 3、使用特性:1)电缆导体的最高额定温度为70℃。2)短路时(最长持续时间不超过5S)电缆导体的最高温度不超过160℃。3)敷设电缆时的环境温度应不低于0℃,最小弯曲半径应不小于电缆外径的10倍。 4、型号、名称和使用范围 6、生产范围

交联聚乙烯绝缘电力电缆 1、产品用途:本产品适用于额定电压(U0/U)为3.6/6至26/35KV电力线路,供输配电能之用。 2、产品标准:GB12706-91额定电压35KV及以下铜芯,铝芯塑料绝缘电力电缆。 3、产品使用特性:(1)电缆在环境温度不低于0℃条件下敷设时,无须预先加温。电缆的敷设落差不受限制。(2)电缆线芯长期允许工作温度不得超过下列规定:外护层是聚氯乙烯套的电缆为90℃;外护层是聚乙烯套的电缆为80℃。(3)线芯短路时(最长持续5S)温度不得超过250℃(4)电缆敷设时的最小弯曲半径规定如下:单芯电缆:20(d+D)±5%;三芯电缆:15(d+D)±5%。式中:D为电缆的实际外径,d为导体的实际外径。 4、产品型号、名称及使用范围 注:一根或二根单芯电缆不允许敷设在铁质管道中。 5、生产范围

聚氯乙烯绝缘电线 1、用途:本产品适用于交流额定电压450/750V及以下的动力装置的固定敷设。 2、产品标准:GB502 3、2-85《额定电压450/750V及以下聚氯乙烯绝缘电缆(电线)固定敷设用电缆(电线)》 3、产品使用特性:1)额定电压U0/U分为450/750V和300/500V。2)电缆的长期允许工作温度:BV-105型……应不超过105℃;其他型号……应不超过70℃。3)电缆的敷设温度应不低于0℃;

GBT9330.1-2008《塑料绝缘控制电缆第1部分一般规定

GB/T 9330.1-2008《塑料绝缘控制电缆 第1部分:一般规定》 国家标准第1号修改单 本修改单经国家标准化管理委员会于XXXX年X月X日批准,自XXXX 年X月X日起实施。 一、第5.3.1条中的“当五芯以下电缆的绝缘线芯采用着色标识时,” 修改为:“当绝缘线芯采用着色标识时,” 二、第6.4.1条“采用0.05~0.10mm的软铜带重叠绕包。” 修改为:“采用0.05~0.10mm的软铜带重叠绕包,重叠率应不小于15%。” 三、第6.5.3条: 挤包或绕包内衬层厚度的最小厚度应不小于表4规定标称值的80%。 表4 内衬层厚度 挤包或绕包前假定直径d mm 内衬层厚度 mm d≤20 1.0 20>d 1.2 挤包的内衬层应不粘连绝缘线芯。 绕包内衬层可采用双层或多层重迭绕包。 修改为: 挤包内衬层厚度的最小厚度或绕包内衬层厚度的平均厚度应不小于表4规定标称值的80%。 表4 内衬层厚度 挤包或绕包前假定直径d mm 内衬层厚度 mm d≤20 1.0 d>20 1.2 挤包的内衬层应不粘连绝缘线芯。 绕包内衬层可采用双层或多层重迭绕包。 当铠装下是金属屏蔽层时,应采用挤包内衬层。

四、第6.6.2条中的: 金属带为涂漆钢带或镀锌钢带。 圆金属丝为镀锌钢丝。 金属带的层数、厚度和宽度应符合表5的规定。 表5 铠装金属带标称厚度和宽度 铠装前假定直径d mm 金属带层数×标称厚度 mm 宽度(不大于) mm ≤15.0 2×0.220 15<d≤25 2×0.225 25<d≤30 2×0.2 30 30<d≤35 2×0.530 35<d≤50 2×0.535 50<d 2×0.545 修改为: 金属带为涂漆钢带或镀锌钢带,金属带的最小厚度应不小于标称厚度的90%。 圆金属丝为镀锌钢丝,金属丝的最小直径应不小于标称直径的95%。 金属带的层数、厚度和宽度应符合表5的规定。 表5 铠装金属带标称厚度和宽度 铠装前假定直径d mm 金属带层数×标称厚度 mm 宽度(不大于) mm ≤15 2×0.220 15<d≤25 2×0.225 25<d≤30 2×0.2 30 30<d≤35 2×0.530 35<d≤50 2×0.535 50<d 2×0.545 ______________________________

0.6~1kv聚氯乙烯交联聚乙烯绝缘耐火电力电缆.

0.6/1kv聚氯乙烯交联聚乙烯绝缘耐火电力电缆 发布:2008-8-1 23:35:47 点击: ( 409 ) PVC(XLPE)InsulatedFire-Resistant Power Cable 产品标准 本产品按GB12706《额定电压35kV及以下铜芯、铝芯塑料绝缘电力电缆》和GB12666《电线电缆燃烧实验方法》标准生产,同时还可根据用户需要按国际电工委员会推荐的IEC标准、英国BS标准、德国DIN标准、美国ICEA标准及日本JIS标准生产。 The product is manufactured according to the standard of GB12706 and GB12666 or IEC,BS,DIN,ICEA,and JIS upon request. 适用范围 本产品适用于工频额定电压0.6/1kV及以下配电线路或工业装置中有耐火要求的固定敷设场所使用。 The product is suitable for use in power distribution lines or fixed installations with rated power-frequency voltage up to and including 0.6/1kV. 使用特性 ·工频额定电压U0/U:0.6/1kV。 Rated power-frequency voltage U0/U:0.6/1kV. ·电缆导体的最高允许长期工作温度(PVC/XLPE):70℃/90℃. Max.permissible continuous operating temperature of conductor (PVC/XLPE): 70℃/90℃ ·短路时(最长持续时间不超过5s)电缆导体最高允许温度 PVC:导体截面≤300mm2-160℃ 导体截面>300mm2-140℃ XLPE:250℃ Max.short-circuit temperature of the conductor shall not exceed(5s maxiumduration): PVC:cross-section of conductor≤300mm2-160℃ cross-section of conductor>300mm2-140℃

常用塑料电线电缆规格型号

电线电缆规格型号

电线电缆型号规格目录 塑料绝缘电力电缆 (3) 控制屏蔽电缆 (7) 电子计算机用控制屏蔽电缆 (12) 本质安全电路用控制电缆 (16) 矿用通信电缆 (18) 矿用信号电缆 (19) 信号电缆 (20) 射频电缆 (21) 补偿导线、电缆 (21) 塑料绝缘安装屏蔽电线、电缆 (22) 航空用氟塑料-46绝缘电线 (22) 聚氯乙烯绝缘尼龙护套电线、电缆 (23) 交联聚乙烯绝缘电缆 (24)

塑料绝缘电力电缆 本产品用于额定电压0.6/1KV的线路中,供输配电能之用(阻燃电缆适用于高层建筑、地铁、发电站、大型工矿企业等电缆敷设密度大,防火要求严格的地方)。 交联聚乙烯绝缘电力电缆 执行标准:交联聚乙烯绝缘电力电缆性能符合GB12706.3-1991等效采用IEC60502-1997,阻燃性能符合GB12666.5-1990等效采用IEC332-1992。(阻燃性能要求不适用于非阻燃型电缆) 使用特性:电缆的额定工作电压U0/U 0.6/1KV;试验电压(持续时间≤5min)3.5KV;电缆导体长期工作温度≤90℃;短路时(持续时间≤5s)电缆导体温度≤250℃;敷设电缆时最小弯曲半径单芯电缆应≥电缆外径的20倍,多芯电缆应≥电缆外径的15倍;电缆敷设时环境温度≥0℃,低于0℃时,预先加温,敷设时不受落差限制。 型号及名称 注:阻燃型电缆型号前加“ZR”;耐火型电缆型号前加“NH”;无卤低烟型电缆型号前加“WD”。 性能参数: 不同土壤热阻系数下的载流量修正系数(土壤热阻系数:PT=1.0k.m/w) 不同环境温度下的载流量修正系数(空气为40℃,土壤为25℃)

电缆的屏蔽方法

电缆的屏蔽方法 电缆导体通过电流时周围就有电场,磁场。当电磁场达到一定强度时就可能对周围的金属构件或电子设备造成不利影响。为消除影响,人们采取了各种措施将电磁场屏蔽。屏蔽构件的屏蔽效应源于对于电磁波的吸收衰减和反射衰减。对低频电磁波的屏蔽以吸收衰减为主,对高频电磁波的屏蔽以反射衰减为主。 屏蔽效应用屏蔽系数S表征。屏蔽系数S用场中某处屏蔽后的电场强度EP或磁场强度HP与该处屏蔽前的电场强度E或磁场强度H之比测算,屏蔽系数越小则屏蔽效果越好S=EP/E=HP/H=0~1。 电缆屏蔽结构有多种,如铜丝或钢丝编织,铜带绕包或纵包,铝塑复合带纵包,铅套或铝套,钢带或钢丝铠装等。一般来说,屏蔽体半径小,厚度大,层数多,材质复合交错,则屏蔽效果好。不同材质的屏蔽效应不同,如铜带屏蔽的反射衰减效应好,而钢带屏蔽的吸收衰减效应好。 电力电缆6KV及以上绝缘外均有金属屏蔽,其功能除屏蔽电场外,还有一个重要功能,就是泄露短路电流。由于电缆接地方式不同,金属屏蔽结构也不同。电缆采用消弧线圈接地时,金属屏蔽采用铜带绕包。电缆若采用小电阻接地,金属屏蔽多采用铜丝疏绕结构或金属套。 另外,10KV及以上电力电缆绝缘内外均有半导体屏蔽,其功能不再是屏蔽电场,而是均化电场,即使绝缘内的电场尽量趋于均匀,从而改善和提供绝缘效能,延长电缆使用寿命。半导体电屏蔽料多为加有炭黑的聚烯烃,有交联型和非交联型,采用三层共挤工艺紧密均匀的附着在绝缘内外,其厚度标准规定。 就屏蔽效果而言,导体屏蔽厚一点好,绝缘屏蔽薄一点,均匀一点好。 使用半导体电屏蔽材料有严格的技术条件,这里仅谈三点,即含水量,电阻率及杂质颗粒的规定数据,一般半导体电屏蔽材料的含水量应不大于1000PPM,超光滑材料应不大于250PPM。导体屏蔽材料的体积电阻率应不大于10000,绝缘屏蔽料的体积电阻率应不大于500。超光滑屏蔽料的杂质颗粒有严格要求,大于200的颗粒应不多于15个/M2,大于500的颗粒应不多于1个/M2。额定电压100KV及以上的电缆应采用光滑屏蔽料。

氟塑料电力电缆

氟塑料电缆简介 氟塑料电缆,英文名:Fluoroplastics Cable,用来专指以氟塑料为外套的电线电缆。氟塑料电缆具有优良的耐候性、耐热性,摩擦系数较小,化学性能稳定,具有较好的电绝缘性能。因此氟塑料电缆在石油、冶金、化工、电力、航天等环境恶劣的行业有着重要用途。在电线电缆的生产中,常用的氟塑料有聚四氟乙烯、聚全氟乙丙烯、聚偏氟乙烯、四氟乙烯和乙烯共聚物等,用以制造各种耐热、耐高温绝缘电线、测(油)井电缆、地质探测电缆、加热电缆,F级和H级电机引接线,耐辐照电线,电磁线,射频同轴电缆,煤矿用阻燃电缆的A型电缆等。氟塑料电缆的特性 氟塑料拥有高度的化学稳定性和耐化学腐蚀性能,耐火、耐高温、阻燃等特性,因此在电线电缆行业有着广泛的应用,特种电缆如:耐高温电缆、阻燃电缆、耐腐蚀电缆等大都采用氟塑料做为护套外层。氟塑料电线电缆拥有的特性如下: 1、阻燃:氟塑料的氧指数高,燃烧时火焰扩散范围小,产生的烟雾量少。用其制作的电缆适合对阻燃性要求严格的地方,例如计算机网络、地铁、车辆、高层建筑等公共场合,一旦发生火灾,人们可以有一定的时间疏离,而不被浓烟熏倒,争取到宝贵的救援时间。 2、电气性能优异:相对于聚乙烯而言,氟塑料的介电常数更低,因此,与同结构的同轴电缆相比较,氟塑料电缆的衰减更小,更适合于高频信号传输,当今电缆的使用频率越来越高已经成为潮流,同时又由于氟塑料能耐高温,所以常用作传输通信设备的内部接线、无线发射馈线与发射机之间的跳线和视频音频线。此外,氟塑料电缆的介电强度、绝缘电阻好,适合作重要仪表仪器的控制电缆。 3、耐高温:氟塑料有着超乎寻常的热稳定性,使得氟塑料电缆能适应 150~200度的高温环境,而常见的聚乙烯、聚氯乙烯电缆只适用于70~90度的工作环境。另外,在同等截面导体的条件下,氟塑料电缆可以传输更大的许用电流,这就大大提高了电缆的使用范围,由于这种独特的性能,氟塑料电缆常用于飞机、舰艇、高温炉以及电子设备的内部布线、引接线等。 4、机械化学性能完美:氟塑料的化学键能高,具有高度的稳定性,几乎不受温度变化的影响,有着优良的耐气候老化性能和机械强度;而且不受各种酸、碱和有机溶剂物影响,因此适用于环境气候变化大、有腐蚀性场合,如石化、炼油、油井仪器控制等。 氟塑料电缆应用的行业:

1KV聚氯乙烯绝缘电力电缆的详细资料:

本产品适用于交流额定电压0.6/1kV的线路中,供输、配电能用。一、生产执行标准 GB12706.2等同采用国际电工委员会IEC60502。 二、使用特点 1.电缆导体长期允许工作温度不超过70℃; 2.短路时(最长持续时间不超过5秒),电缆导体的最高温度不超过160℃; 3.敷设电缆时的环境温度应不低于0℃。 三、电缆的型号、名称及适用场合 注:本公司另可根据用户需要提供普通阻燃型、低烟低卤阻燃型、低烟无卤阻燃聚烯烃型等类型的产品。 1、普通阻燃型:在原型号前加“ZR”,如ZR-VV 2、低烟低卤阻燃型:

a 、在原型号前加“DDZ”,如DDZ-VV b 、在原型号前加“ZR”,并将型号中字母“V”改写为“VD”如ZR-VDVD 3、低烟无卤阻燃聚烯烃型:在原型号前加“ZR”并将型号中字母“V”改写为“E”,如ZR-EE 四、型号、芯数、标称截面 注:(1)用户也可向本公司订购5芯制电力电缆,如:3+2型、4+1型。 (2)中性线可以采用双色线。 五、交货长度 电缆交货长度按双方协议规定,长度计量误差不超过±0.5% 金属屏蔽电力电缆 规格型 号: 产品报 价: 产品特 点: 适用于额定电压0.6/1kV 及以下的电力线路中作输送电能用。本产品具有较强的抗电磁干 扰、抗雷击及均匀电场,改善供电品质的特性, 特别适用具有精密电子装置的场所,如计算机中心、航空航天监控中心、智能大厦等。

一、产品用途 适用于额定电压0.6/1kV及以下的电力线路中作输送电能用。本产品具有较强的抗电磁干扰、抗雷击及均匀电场,改善供电品质的特性,特别适用具有精密电子装置的场所,如计算机中心、航空航天监控中心、智能大厦等。 二、执行标准 本产品按Q/HX-15设计制造 烯绝缘电力电缆有所不同,在型号上以“-P”后缀加以区分,如:VV-P、YJV-P、YJLV22-P 等等。

常用控制电缆规格型号表及说明

KVV控制电缆规格型号表

二、使用说明 标准: 聚氯乙烯绝缘控制电缆标准:产品标准:GB9330.2-88《聚氯乙烯绝缘和护套控制电缆》,IEC60227(60502,60332); SABS。 本产品供交流额定电压450V/750V或直流电压1000V及以下配电装置中电器,仪表接线之用。 应用: 控制电缆适合布线的电气控制设备和仪器,监测和控制回路,电气保护和测量电源分配单元服务条件的情况下,额定电压为450/750V AC。 铺设: 聚氯乙烯绝缘电缆长期工作温度为70℃; 交联聚乙烯绝缘电缆长期工作温度为90℃ 敷设电缆的温度不能低于0℃。 允许弯曲半径: 非铠装电缆(R):R≥6D(D:电缆外径); 铠装或铜胶带屏蔽电缆:R≥12D; 屏蔽软电缆:R≥10D。 注释: 具体电缆芯数系列为,2,3,5,7,8,10,12,14,16,19,24,27,30,37;

R--连接用软电缆(电线),软结构; V--绝缘聚氯乙烯 V--聚氯乙烯绝缘 V--聚氯乙烯护套; B--平型(扁形) S--双绞型; A--镀锡或镀银; F--耐高温; P--编织屏蔽 P2--铜带屏蔽 P22--钢带铠装; Y--预制型、一般省略,或聚烯烃护套 FD--产品类别代号,指分支电缆,将要颁布的建设部标准用FZ表示,其实质相同;YJ--交联聚乙烯绝缘; V--聚氯乙烯绝缘或护套; ZR--阻燃型; NH--耐火型; WDZ--无卤低烟阻燃型; WDN--无卤低烟耐火型; 例: RV --铜芯、氯乙烯绝缘,连接电缆(电线); AVR-- 镀锡、铜芯、聚乙烯绝缘、平型、连接软,电缆(电线); RVB-- 铜芯、聚氯乙烯平型连接电线; RVS --铜芯、聚氯乙烯绞型连接电线; RVV --铜芯、聚氯乙烯绝缘、聚氯乙烯护套、圆形连接软电缆 ARVV-- 镀锡、铜芯、聚氯乙烯绝缘、聚氯乙烯护套、平形连接软电缆 RVVB --铜芯、聚氯乙烯绝缘、聚氯乙烯护套、平形连接软电缆 RV-105 --铜芯耐热105℃、聚氯乙烯绝缘、聚氯乙烯绝缘、连接软电缆 AF-205AFS-250AFP-250 --镀银、聚氯乙氟塑料绝缘、耐高温-60℃~250℃、连接软电线 三、常用电(线)缆类型线缆规格型号含义: BV--表示单铜芯、聚氯乙烯普通绝缘电线,无护套线。 适用于交流电压450/750V及以下动力装置、日用电器、仪表及电信设备用的电线电缆。

KVV聚氯乙烯绝缘控制电缆技术规范

1、产品名称:聚氯乙烯绝缘控制电缆 型号:KVVR、KVVRP 2、使用条件: 2.1导体的最高额定工作温度:70℃ 2.2短路时(最长持续时间不超过5s)电缆导体的最高温度不超过:160℃。 3、主要采用标准: GB9330-88塑料绝缘控制电缆 4、技术参数 5、技术要求 5.2.1导体 导体材料采用TU1或T1型铜杆,其组成、性能和外观符合GB9330-88的规定。 5.2.2 绝缘 绝缘采用PVC绝缘材料,其性能符合GB9330.2-88标准规定。绝缘厚度标称值为GB9330.2-88的规定,最薄点厚度不小于标称值的90%-0.1mm。 5.2.3填充 缆芯采用非吸湿性材料填充,紧密无空隙。 5.2.4 包带层 电缆包带层采用非吸湿性带材。 5.2.5 屏蔽层 屏蔽电缆屏蔽层采用铜丝编,其编织密度不小于80%。 5.2.6 护套 电缆外护套采用PVC护套料,标称厚度满足GB9330.2的规定。外护套的最

薄点厚度不小于标称值的85%-0.1mm。 5.2.7 外观标记 成品电缆的护套表面有生产厂家、电缆型号、规格、额定电压和米标的连续标志,标志字迹清楚、容易辨认,耐擦。 6、电缆的包装 6.1 供货商对所有电缆进行有效包装,电缆断点应采用热缩套可靠密封,以防潮气侵入,成圈长度为100m,成盘长度应不小于100m。 6.2 每盘电缆均附有合格证。 6.3电缆应避免露天存放,电缆盘不允许平放。 6.4运输电缆时,严禁从高处扔下装有电缆的电缆盘,严禁机械损伤电缆。 6.5吊装包装件时,严禁几盘同时吊装。在车辆、船舶等运输工具上,电缆盘必须放稳,并用合适方法固定,防止互撞或翻倒。 6.6电缆盘外有下列文字和符号标志: a 制造厂名或商标等字样 b 电缆型号及规格 c 长度,m;毛重,kg d 制造日期:年月 e 表示电缆盘正确旋转方向的符号 f 标准编号 7、电缆运输及保管: 7.1电缆应避免露天存放,电缆盘不应平放; 7.2运输中严禁从高处扔下装有电缆的电缆盘,严禁机械损伤电缆; 7.3吊装包装件时,严禁几盘同时吊装,在车辆,船舶等运输工具上,电缆盘必须放稳,并用合适方法固定,防止互撞或翻倒。 8、试验 产品试验按照GB5023标准执行。 一、产品名称:聚氯乙烯绝缘控制电缆

金属电缆屏蔽

金属屏蔽应由一根或多跟金属带,金属编制,金属丝的同心层或金属丝与金属带的组合结构组成。 金属屏蔽也可以是金属套或符合要求的金属铠装层。 选择金属屏蔽材料时,应也别考虑存在腐蚀的可能性,着不仅为了机械安全,而且也为了电气安全。 金属屏蔽饶宝的搭盖和间隙应符合下列要求: 金属屏蔽中铜丝的电阻,适用时应符合国标要求。铜丝屏蔽的标称截面积应根据故障电流容量确定。 铜丝屏蔽应由一层重叠饶包的软铜线组成,其表面采用反向饶包的铜丝或铜带扎紧。相邻铜丝的平均间隙应不大于4mm 铜带屏蔽应由一层重叠绕包的软铜带组成,也可采用双层铜带间隙绕包,铜带间的搭盖率为铜带宽度的15%(标称值),最小搭盖率应不小于5%。 铜带标称厚度为; 单芯电缆≥0.12mm 多芯电缆≥0.10mm 铜带的最小厚度应不小于标称值的90% 金属网和金属箔都能起来屏蔽作用,有些电缆中仍金属网,也是屏蔽网. 没有屏蔽的电缆在传输中不一定会产生信号丢失,这要看周围的环境是不是有很多干扰,如果有变频器等干扰源,非屏蔽电缆可能会丢失数据.但有了屏蔽层,也不等于说就完全不会丢失数据. 干扰和屏蔽都是相对的. 屏蔽层为了均匀导电线芯和绝缘电场,6kV及以上的中高压电力电缆一般都有导体屏蔽层和绝缘屏蔽层,部分低压电缆不设置屏蔽层。屏蔽层有半导电屏蔽和金属屏蔽两种。 (1)半导电屏蔽 半导电屏蔽层通常设置在导电线芯的外表面和绝缘层的外表面,分别称为内半导电屏蔽层和外半导电屏蔽层。半导电屏蔽层是由电阻率很低且厚度较薄的半导电材料构成。内半导电屏蔽层是为了均匀线芯外表面电场,避免因导体表面不光滑以及线芯绞合产生的气隙而造成导体和绝缘发生局部放电。外半导电屏蔽层与绝缘层外表面接触很好,且与金属护套等电位,避免因电缆绝缘表面裂纹等缺陷而与金属护套发生局部放电。 (2)金属屏蔽 对于没有金属护套的中低压电力电缆,除了设置有半导电屏蔽层外,还要增加金属屏蔽层。金属屏蔽层通常由铜带或铜丝绕包而成,主要起到屏蔽电场的作用。

各种电缆型号大全

各种电缆型号大全 2009-12-28 10:22 电线电缆型号含义 绝缘层 导体 护套 外护层————— 额定电压(千伏) 线芯数×线芯截面(毫米2)+中性线芯(用“1”表示)×中性线芯截面(毫米2) 型号组成简单名称代号型号组成简单名称代号 绝缘层: 纸绝缘(Z) /橡皮绝缘(X) /聚氯乙烯绝缘(V) /聚乙烯绝缘(Y) /交联聚乙烯绝缘(J) 特征: 不滴流(D) 充油(CY) 滤尘器用(C) 导体: 铜/铝/ 不表示 L 外护层防腐: 一级(1)/二级(2) 护套: 铅包(Q)/铝包(L)/聚氯乙烯护套(V)/非燃性橡套(HF)/ 麻包(1)/铠装麻包(2)/ 钢带铠装麻包(3) 细钢丝铠装麻包(5)

相应裸外护层(0) 相应铠装外护层(9) 聚氯乙烯护套(02) 聚乙烯护套(03) 特征: 统包型/分相铅包、分相护套 干绝缘(F)/ 不表示(P) 油浸纸绝缘电力电缆 油浸纸绝缘电力电缆类产品,以绝缘纸的字母“Z”代号列为首位,其余各项型号编制及字母含义如下: 类别、用途导体绝缘护套特征外护层 Z-纸绝缘电缆T-铜 L-铝Z-油浸纸Q-铅套 L-铝套CY-充油 F-分相 D-不滴流 C-滤尘用02,03,20,21,22, 23,30,31,32,33, 40,41,42,43, 441,241等

注:a.数字涵义详见以下附表。b.铜芯代表字母T一般省略不写。 例如: Z Q D 02 纸绝缘电缆 铅护套 不滴流 聚氯乙烯外护套 铜芯不滴流油浸纸绝缘铅套聚氯乙烯套电力电缆 Z L L 32 纸绝缘电缆 铝线芯 铝护套 细圆钢丝铠装聚氯乙烯外套 铝芯粘性油浸纸绝缘铝套裸细钢铠装电力电缆 电缆外护层的型号按铠装层和外被层的结构顺序用阿拉伯数字表示。每一数字表示所采用的主要材料和意义见下表。 标记铠装层标记外被层 0 无0 无 1 - 1 纤维层 2 双钢带(24-钢带、粗圆钢丝)2 聚氯乙烯套 3 细圆钢丝3 聚乙烯套

常用塑料电线电缆规格型号

电线电缆规格型号 扬州市中能电缆有限公司 电线电缆型号规格目录 塑料绝缘电力电缆 (3) 控制屏蔽电缆 (7) 电子计算机用控制屏蔽电缆…………………………………………………………… 12 本质安全电路用控制电缆……………………………………………………………… 16 矿用通信电缆…………………………………………………………………………… 18 矿用信号电缆…………………………………………………………………………… 19 信号电缆………………………………………………………………………………… 20 射频电缆………………………………………………………………………………… 21 补偿导线、电缆………………………………………………………………………… 21 塑料绝缘安装屏蔽电线、电缆………………………………………………………… 22 航空用氟塑料-46绝缘电线…………………………………………………………… 22 聚氯乙烯绝缘尼龙护套电线、电缆…………………………………………………… 23 交联聚乙烯绝缘电

缆 (24) 塑料绝缘电力电缆 本产品用于额定电压0.6/1KV的线路中,供输配电能之用(阻燃电缆适用于高层建筑、地铁、发电站、大型工矿企业等电缆敷设密度大,防火要求严格的地方)。 交联聚乙烯绝缘电力电缆 执行标准:交联聚乙烯绝缘电力电缆性能符合GB12706.3-1991等效采用IEC60502-1997,阻燃性能符合GB12666.5-1990等效采用IEC332-1992。(阻燃性能要求不适用于非阻燃型电缆) 使用特性:电缆的额定工作电压U0/U0.6/1KV;试验电压(持续时间≤5min)3.5KV;电缆导体长期工作温度≤90℃; 短路时(持续时间≤5s)电缆导体温度≤250℃;敷设电缆时最小弯曲半径单芯电缆应≥电缆外径的20 倍,多芯电缆应≥电缆外径的15倍;电缆敷设时环境温度≥0℃,低于0℃时,预先加温,敷设时不受 落差限制。 型号及名称 注:阻燃型电缆型号前加“ZR”;耐火型电缆型号前加“NH”;无卤低烟型电缆型号前加“WD”。 性能参数: 不同土壤热阻系数下的载流量修正系数(土壤热阻系数:PT=1.0k.m/w) 不同环境温度下的载流量修正系数(空气为40℃,土壤为25℃)

电缆的屏蔽

电缆的屏蔽 1.引言 电缆屏蔽有非金属屏蔽和金属屏蔽两种形式。采用哪一种屏蔽形式取决于电缆的种类,如电力电缆主要是为了屏蔽和均化电场,承载短路电流,而通讯电缆则要屏蔽电磁场,以消除线芯间和外部对电缆的干扰。电力电缆的屏蔽同时具有非金属屏蔽和金属屏蔽形式,具体取决于电缆的电压等级和短路电流的大小等,对于金属屏蔽部分还取决于以及金属材料的导电性、热性能、结构和加工方式等,通讯电缆则多为金属屏蔽。这里就电缆的屏蔽作用、结构和材料进行了简单介绍。 2.屏蔽的作用 2.1 均化电场 实心的导体相对表面比较光滑,电场的分布比较均匀。绞合的导电线芯由于是有多根单线组成,线芯表面各点电场分布不均匀,单线半径的大小和其表面场强的大小成反比关系,这就产生多导丝效应。导体因加工产生的毛刺、粉屑,造成尖端放电,也需要导体屏蔽。为了使导体表面的电场分布相对比较均匀,只有绕包带屏蔽和挤出屏蔽层,才能均化电场消除这些效应。 导电线芯电场分垂直和相切两个方向的分量。如没有半导电层,对于绕包类型的绝缘来说易产生移滑放电;另外切向方向的场强使绝缘的耐压降低10~15倍,降低了绝缘强度和绝缘的效果。 多芯电缆填充处有电场,由于填充处绝缘材料的本身耐电强度较低,因此使电缆的整体绝缘水平下降。半导电材料主要是由部分碳黑组成,碳黑除有半导电的作用外也可以吸附气体杂质,使相应面的绝缘的长期电场强度降低,避免电缆绝缘外表面发生游离,提高电缆的使用寿命。 为了避免电场过于集中,常采用半导电层结构改变电场的方向,避免绕包绝缘产生移滑放电,使多芯电缆的填充处于无电场状态;半导电层中的炭黑可以吸附气体杂质,屏蔽气泡不受电场作用,对于绞合的导体,由于是由多根单线胶合而成,表面单线突出的电场强度和凹进部分相比可提高30%。 2.2 减少干扰 电场和磁场是交互变化而存在的统一体,变化的电场产生变化的磁场影响周围媒质,从而产生对其他载流回路产生干扰,电磁场的作用是电场和磁场产生干扰作用的总和。 在电场和磁场的作用下,电流对回路之间的不平衡而引起的电干扰和磁干扰。干扰的产生可分为电感、电容、电阻在回路产生相应的感抗、容抗和阻抗,而产生相应的损耗。 通信电缆的频率较高,比较容易产生干扰,电力电缆的频率较低,而比较容易产生损耗。采用合理的屏蔽结构和有效的接地方式,就能够较少干和损耗。 2.3 热屏蔽 由于导体的导电性能比较好,对流过其本身的电流有较小的电阻,因此导电率较高。绝缘体的绝缘性能较高,对电流又较大的电阻,电流几乎不可能穿透绝缘体,因此绝缘电阻率较高。导电性能高的材料也相对有较高的导热性能,绝缘性能较高的材料必然有较高的热阻,导电性能的不同对热导的性能也有所不同,半导电材料的导电性能和导热性能介于导体和绝缘体之间。 如果电力电缆发生短路,导体流过大的电流使其温度突然升高,由于采用了内半导电屏蔽层,就防止了过高的温度直接作用到绝缘层上,不致因热冲击而损伤绝缘层,在这种情况下,内屏蔽层就起到了热屏蔽作用,也可以称为热缓冲层。 在绝缘或半导电屏蔽表面上绕包或挤出一层金属屏蔽,不但使圆形导体电缆填充处无电场,而且因为金属屏蔽散热效果好,在意外短路的情况下,可以承受一定的短路电流,避免绝缘过热产生热击穿。 2.4 防护作用 对高分子材料,因其内部和形成整个混合体的结构不同,在一定条件下水对材料都有一定的渗透率。在不同敷设条件和特殊环境下,为了使电缆在设计的使用寿命下安全运行,就要采用相应的防护结构。金属带或丝屏蔽主要是在发生短路的情况下,在一定时间内承受一部分短路电流,避免绝缘在过高的电流影响下产生热击穿。前提是金属屏蔽必须有牢靠的接地措施,电压电流的大小应满足设计的要求,总之不应产生过大的损耗。电力电缆的金属屏蔽的截面大小是根据电压的大小来确定的,屏蔽的面积不能小于有关标准的规定,线路电压和屏蔽截面的关系见表1。金属屏蔽的截面应尽量满足表1的要求,避免产生不必要的经济损失。

电线电缆绝缘材料的选择

电线电缆绝缘材料的选择 10.0 PVC胶粒
10.1 基本配方
VC粉:主体一般常用S60、S65、S70﹔
可塑剂:主要目的在调整软硬度,提高耐寒绝缘等作用﹔
填充剂:目的在增强加热,光之安全性,及绝缘性﹔
改质剂:依特性要求添加﹔
安定剂:抑制PVC内之少量游离Cl-分解﹔
防火剂:增强耐烧性﹔
染颜料:颜色调配。
10.2 硬度
国际上常以shore A表示之,而国内软硬度常以P%表示,例如:50kg之PVC料,可塑剂40kg时是以80P,50gPVC料,可塑剂55kg时是以110P表示即可塑剂愈多P数愈大,PVC 胶粒愈软而萧氏硬度(shore A)度数愈大,PVC胶粒愈硬。
10.3 移行说明
电气用品之外壳……等常用的塑料材质大部份为PS,ABS,HIPS,电线为PVC塑材料时,由于含有可塑剂(软化剂),而有此可塑剂会移行者,会将PS,ABS,HIPS塑料壳侵蚀,因此有非移行的要求,也就是PVC材料不能移。
10.3.1 移行的试验方法
将试片(ABS,或PS或HIPS)两片(长50x宽50x厚20mm),中间夹PVC电线,再上下两层用玻璃盖住并用500±5g砝码压住,施以不同时间(24,48,72小时)不同温度(50℃,60℃,70±2℃)之条件下,测试(条件由客户设定),测试后取出试片,用肉眼观察,试片上不能很轻易的看出痕迹,亦即需极费眼力才能看出来。
ABS = Acrylonitrile Butadiene Styrene Terpolymer
苯乙烯,丁二烯,丙烯,参聚合体
S = POL YSTRRENE 聚苯乙烯
HIPS = High Impact Polystyrene 高冲击聚苯乙烯
10.3.2 PVC胶粒应具下列性质
耐热性( Thermal Stability ) ﹔
硬度( Hardness )﹔
安全性( Safety )﹔
老化性( Aging Properties ) ﹔
机械性质( Mechanical Properties )﹔
耐燃性( non-flammability )﹔
电气特性( Electrical Properties )﹔
耐候性( Weather ability )﹔
光安定性( Light Stability )﹔
低温特性( Low Temperature Properties )。
11.0 塑料常用特性名词解释
11.1 抗张强度:(Tensile Strength)
将试样(如哑铃片……等)拉断时所需要之应力,用之单位为PSI或kg/mm2。
11.2 热变形(Heat Distortion)
将材料适当的取样后,将其加热至一定之温度后,试验该材料之外形改变情况。其计算公式如下:
11.3 热冲击(Heat Shock)——试验材料稳定性方法之一,将材料在特定的时间内卷绕于规定之圆棒上,暴露于高温中,不得有龟裂现象发生。
11.4 冷弯(Cold Bend)——将电缆之试样绕在规定之圆棒(Mandrel)上,而置于特定温度之冷室中,通常为零下之温度。再将试样取出作弯曲试验,则可试验出材料之破坏程度或有无缺点。
11.5 延伸(Elongation)——试样拉断时的伸长情形
11.6 焊接性(日文:半田性)——PVC芯线等在焊接或热镀时其塑料部份后缩收,所以其材质要经X—RAY处理成架桥,或改其塑料本身性质,如:SR—PVC。
11.7 老化(Aging)——仿真电缆经长时间的使用后,其物理性(抗张延伸)改变的情形。
11.8 额定温度(Temperature Rating)——绝缘材料在连续使用之情况下,其基本特性不会发生变化或损失时,所能容许之最高温度。如交连PE 为90℃,PVC有60℃,75℃,90℃,105℃,PE为75℃等。
11.9 额定电压(V oltage Rating)——依照规定或标准可连续实施于各种电缆电缆之最高允许电压。
11.10 绝缘阻抗(Insulation Resistance)——加于绝缘体两极间之电压与电流之比,以公式表示为R=E/I,其单位一般用MΩ(百万欧姆表示之)。
11.11 耐电压(介质强度)(DielectricStrength)——绝缘材质在破坏之前所能承受之电压,介质强度在材料中是一个非常重要特性,在同一种耐电压情况下,介质强度好的材质,其绝缘厚度可以较薄。
12.0 塑料之耐燃测试
依UL规定UL Standard 94 分为水平燃烧(94—HB)及垂直燃烧
94V-0,94V-1,94V-2。
13.0 发泡
目的:在改变或降低成品的电容(介电常数)并使成品轻量化,小型化,进而节省材料,达到提高品质与降低成本的最终目的,一般常用方法
(a) 物理发泡
(b) 化学发泡,化学发泡在加热过程中,发泡剂分解

相关主题
文本预览
相关文档 最新文档