OPT-1062A1Series
Transceiver Module for 1.0625GBd Fibre Channel
DC/DC (5V)AC/DC (5V)AC/AC TTL (5V)AC/AC PECL (5V)OPT-1062A1G1A/B/C/D OPT-1062A1G3A/B/C/D OPT-1062A3G2A/B/C/D OPT-1062A1G2A/B/C/D
Compliant with Fibre Channel Standard SC Duplex Multimode Transceiver
Industrial Standard 1x9Footprint,Cost Effective Design
850nm Vertical Cavity Surface Emitting Laser (VCSEL)Source Technology Data Link up to 550Meters in 50/125MMF,300Meters in 62.5/125MMF.Single +5V Power Supply.Available for PECL and TTL Logic Interface.Class 1FDA and IEC laser safety compliant (Laser Class 1Product)
Transceiver Module for 1.0625GBd Fibre
Channel
Note (1).With BER better than orequal to 1x10,measured in the center of the eye opening with 2-1NRZ PRBS.Note (2).These are 20%~80%values.
-1223OPT-1062A1Series
Transceiver Module for 1.0625GBd Fibre Channel
Recommended Circuit Schematic (For OPT-1062A1G1)
Multimode 850nm Gigabit Ethernet /Fiber Channel 1x9Transceiver,DC/DC,5V Transceiver Version
C1/2/3=4.7uF C4/5/6/7=10nF L1/2=1uH R1/2=68R3/4=191R7/8=270R5/6/9/10/11/12Depend on SerDes chip used and desired line termination (50Strip line)
R13=510
When we want PECL output in SD pin we use R13=510.
Value of R5/6/9/10/11/12may very as long as proper 50termination to VEE ,it depend on SerDes chip used and desired line termination.All the transceiver of Delta contains an automatic shutdown circuit.Reset depends on the power OFF and then ON.For good EMI performance the power supply filter is https://www.doczj.com/doc/a914064200.html,e short tracks from the inductor L1/2to the module VccTx/VccRx .This recommend Circuit assume Gigabit Ethernet /Fiber Channel using 5V power supply and SerDes Chip using 3.3/5V power supply.
OPT-1062A1Series
Recommended Circuit Schematic (For OPT-1062A1G3)
Multimode 850nm Gigabit Ethernet /Fiber Channel 1x9Transceiver,AC/DC,5V Transceiver Version
C1/2/3=
4.7uF
C4/5/6/7=10nF L1/2=1uH R7/8=270R5/6/9/10/11/12Depend on SerDes chip used and desired line termination (50Strip line)
R13=510When we want PECL output in SD pin we use R13=510.
Value of R5/6/9/10/11/12may very as long as proper 50termination to VEE ,it depend on SerDes chip used and desired line termination.All the transceiver of Delta contains an automatic shutdown circuit.Reset depends on the power OFF and then ON.For good EMI performance the power supply filter is https://www.doczj.com/doc/a914064200.html,e short tracks from the inductor L1/2to the module VccTx/VccRx.This recommend Circuit assume Gigabit Ethernet /Fiber Channel using 5V power supply and SerDes Chip using 3.3/5V power supply.
Transceiver Module for 1.0625GBd Fibre Channel
OPT-1062A1Series
Recommended Circuit Schematic (For OPT-1062A1G2or OPT-1062A3G2)
Multimode 850nm Gigabit Ethernet /Fiber Channel 1x9Transceiver,AC/AC,5V Transceiver Version
C1/2/3=4.7uF
L1/2=1uH R7/8=270R5/6/9/10/11/12Depend on SerDes chip used and desired
line termination (50Strip line)
R13=510
Value of R5/6/9/10/11/12may very as long as proper 50termination to VEE ,it depend on SerDes chip used and desired line termination.All the transceiver of Delta contains an automatic shutdown circuit.Reset depends on the power OFF and then ON.For good EMI performance the power supply filter is https://www.doczj.com/doc/a914064200.html,e short tracks from the inductor L1/2to the module VccTx/VccRx.This recommend Circuit assume Gigabit Ethernet /Fiber Channel using 5V power supply and SerDes Chip using 3.3/5V power supply.
When we want PECL output in SD pin we use R13=510,and no connector when we want TTL output.Transceiver Module for 1.0625GBd Fibre Channel
OPT-1062A1Series
Transceiver Module for1.0625GBd Fibre Channel
MECHANICAL DIMENSIONS
Unit:mm TYPE:A(Flush Shielding)
OPT-1062A1Series
Transceiver Module for1.0625GBd Fibre Channel
MECHANICAL DIMENSIONS
Unit:mm TYPE:B(Protruding Shielding)
OPT-1062A1Series
Transceiver Module for1.0625GBd Fibre Channel
MECHANICAL DIMENSIONS
Unit:mm TYPE:C(Entirely Wrap-Up)
OPT-1062A1Series
Transceiver Module for1.0625GBd Fibre Channel
MECHANICAL DIMENSIONS
Unit:mm TYPE:D(Clamp Shielding)