巨人通力电梯图纸说明 drawing list 图纸目录 position number table 代码对照表 machinery machine room wiring diagrams 机房 power supply 电源 high voltage 高压 controller external connections 外部接线 group connections 群控接线 option interface unit 选项接口 shaft wiring diagrams 井道 control panel connections served top floor 顶层服务楼层 specials at top floors 特殊顶层服务楼层 sered intermetiate floors 中间服务楼层 specials at intermediate floors 特殊中间服务楼层extra long fllor to fllor distance 特殊长间距楼层served first fllor 第一层服务楼层 specials at first fllor 特殊第一层服务楼层 pit wiring 底坑接线 key switches at landings 厅开关

emergency exits in shaft 井道 car diring diagrams 轿厢接线图 travelling cable 随缆 inspection drive 检修运行 safety switches 安全开关 limit switches 极限开关 doors 门 car network,cop 轿厢网络,COP car calls 轿内召唤 car operating panel,general 轿厢操作面板,通用 car operating panel,optional 轿厢操作面板,选项car lighting and ventilation 轿厢照明和通风 circuit diagrams contactor control 控制 machinery control 控制 safety chain 安全回路 car,door contacts 轿厢,门触点 deceleration switches,position switches 检修运行,eceleration switches 减速开关 load weighing 称重 floor computer network 楼层计算机网络 door control AMD 门机控制 AMD

通力电梯更换各电路板后的自学习

课程描述

目录 1 LCE井道信号装置的检查 ............................... 错误!未定义书签。 杆型探头 .......................................... 错误!未定义书签。 U型感应器......................................... 错误!未定义书签。 2. LCE 通过参数修改楼层显示............................ 错误!未定义书签。 操作界面的介绍 .................................... 错误!未定义书签。 修改楼层显示 ...................................... 错误!未定义书签。 3 LCE 故障处理......................................... 错误!未定义书签。 读取故障 .......................................... 错误!未定义书签。 故障处理 .......................................... 错误!未定义书签。 4 LCE 更换LCECPU 板(除LCECPU561外) ................... 错误!未定义书签。 LCECPU 板的类型 ................................... 错误!未定义书签。 更换 LCECPU 板 .................................... 错误!未定义书签。 5 LCE 更换除LCECPU板之外的其他部件.................... 错误!未定义书签。 机房部份: LCEADO 板 ............................... 错误!未定义书签。 轿厢部份 .......................................... 错误!未定义书签。 6 LCE 修改参数......................................... 错误!未定义书签。 菜单介绍 .......................................... 错误!未定义书签。 修改参数 .......................................... 错误!未定义书签。 7 LCE D7 D8更换 ....................................... 错误!未定义书签。 LCE D7 更换 ....................................... 错误!未定义书签。

巨人通力电梯常见故障处理方法修订稿

巨人通力电梯常见故障 处理方法 WEIHUA system office room 【WEIHUA 16H-WEIHUA WEIHUA8Q8-

巨人通力电梯常见故障处理方法 以下几点是针对0091、0101、0001、0083、0036、0003等故障的基本处理方法,通过分析,许多故障是由信号干扰或钢带不垂直、门锁触点没调整到位造成的。 如出现上述故障请先根据以下方法自行处理: 1、调整钢带垂直度,前后左右与读码器(bar)刻度线对齐,左右偏差控制在1MM以内; 2、检查用户总地线、厢总地线是否可靠; 3、控制柜内动力线屏蔽线接地,进线接地线是否可靠,铜条上8条接地线有无漏接; 4、接地线,制动电阻接地线是否可靠; 5、主板的12颗固定螺栓是否都已紧固; 6、轿顶检修厢内铜条接地是否可靠或漏接; 7、读码器电缆应是屏蔽线,并且屏蔽线在检修盒内要接地,电缆不能与轿厢照明、风扇、门机电源电缆绑扎在一起; 8、把随行电缆多余的电线一端(控制柜则)接地; 9、把门机的外接地固定处的油漆刮掉,然后紧固; 10、随行电缆内轿厢照明电源(AC220V)可能会对信号造成干扰,条件许可的可以把轿厢照明电源关掉,然后试运行观察;??或把轿厢照明电源进线改接到的AC220V的输出端试运行观察; 11、把读码器的A、B通道信号线换成屏蔽线:轿顶板插件XB46/7— XT1/6—XC11/6和XB46/6—XT1/5—XC11/5两条信号线跟随行电缆中超载信号

线(轿顶板插件XT11/1-4与控制柜驱动板中左上角插件XW/1-3的两根屏蔽线)相互调换; 12、可以考虑去除轿内COB/CEB或FCB上的终端电阻测试; 13、检查相序;(0021) 14、检查门锁主触点与弹簧触点的压缩行程(控制在3-4MM); 15、检查辅助触头;(平层时有0001故障) 16、检查厅(轿)门锁(无故障突停或0022、0023) 17、检查主接触器(0036) 18、检查开门到位(0077) 19、检查抱闸开闸及其电源接线、制动电阻(0101) 20、检查77N磁钢位置(0148、0154) 21、检查77U磁钢位置(0149、0154) 22、检查应急蓄电池(0169) 23、检查XM12、24V电源(0213) 24、检查楼层扩展板(1201~12NN) 25、检查轿厢功能板(1301~13NN) 26、检查井道信息板(1401~14NN) 以上方法处理后仍不能解决,再根据故障现象更换相关的读码器、LCECCBS、LCEDRV、LCECPU等板。 消防联动:需要一组常开无缘的信号。单梯串接FR1~1或FR1~2,并联梯需要两台都接同一个线号。

电梯工作原理

电梯工作原理 曳引绳两端分别连着轿厢和对重,缠绕在曳引轮和导向轮上,曳引电动机通过减速器变速后带动曳引轮转动,靠曳引绳与曳引轮摩擦产生的牵引力,实现轿厢和对重的升降运动,达到运输目的。固定在轿厢上的导靴可以沿着安装在建筑物井道墙体上的固定导轨往复升降运动,防止轿厢在运行中偏斜或摆动。常闭块式制动器在电动机工作时松闸,使电梯运转,在失电情况下制动,使轿厢停止升降,并在指定层站上维持其静止状态,供人员和货物出入。轿厢是运载乘客或其他载荷的箱体部件,对重用来平衡轿厢载荷、减少电动机功率。补偿装置用来补偿曳引绳运动中的张力和重量变化,使曳引电动机负载稳定,轿厢得以准确停靠。电气系统实现对电梯运动的控制,同时完成选层、平层、测速、照明工作。指示呼叫系统随时显示轿厢的运动方向和所在楼层位置。安全装置保证电梯运行安全。 1、电梯是如何运行起来的? 电梯有一个轿厢和一个对重,通过钢丝绳将它们连接起来,钢丝绳通 过驱动装置(曳引机)的曳引带动,使电梯轿厢和对重在电梯内导轨上做 上下运动。 2、电梯的钢丝绳是否会断? 电梯用的钢丝绳是电梯专用的,国家有专门的规定和要求。钢丝绳的 配置不只是为承担电梯轿厢和额定载重量,还考虑到了曳引力的大小,因此,钢丝绳的抗拉强度大大的大于电梯的载重量,它们的安全系数都在12

以上,通常电梯都配有四根以上的钢丝绳,一般情况下电梯钢丝绳是不会同时断的。 3、电梯运行中突然停电是否有危险? 电梯运行中如遇到突然停电或供电线路出现故障,电梯会自动停止运行,不会有什么危险。因为电梯本身设有电气、机械安全装置,一旦停电,电梯的制动器会自动制动,使电梯不能运行。另外,供电部门如有计划的停电,事先会通知的,电梯或提前停止运行。 4、电梯运行突然加快怎么办? 电梯的运行速度不论是上行还是下行,均应在规定的额定速度范围内运行,一般不会超速,如果出现超速,在电梯控制系统内是有防超速装置,此时,该装置会自动动作,使电梯减速或停止运行。 5、电梯轿厢超载能自动控制吗? 电梯的载重量根据需要有所不同,电梯只能在规定载重量之内运行,超出时,电梯会自动报警,并不能运行。 6、电梯关门时被夹是否会对人造成伤害? 电梯在关门过程中,如果厅轿门碰到人或物,门会自动重新开启,不会伤人。因为在门上设有防夹人的开关,一旦门碰触到人或物,此开关动作使电梯不能关门,并重新开启,然后重新关门。另外,关门力是有规定的,不会达到伤人的程度。 7、电梯的厅门能否扒开? 电梯的厅门在厅外是不能扒开的,必须用专用工具才能开启(专用工具由维修人员掌管)。乘客是不准扒门的,更不能打开,否则会有坠落井道的危险。 8、怎样召唤电梯? 当你需要乘坐电梯时,应在电梯厅的呼梯面板上选择你要去的方向按钮。上行按“向上”方向按钮,下行按“向下”方向按钮。 9、电梯蹲底和冲顶是否有防护措施? 电梯蹲底就是电梯的轿厢在控制系统全都失效的情况下,会超越首层平层位置而向下行驶,直至蹲到底坑的缓冲器上停止。缓冲器就是为此而设置的防护装置,此防护装置根据电梯的运行速度的不同,分弹簧式和液压式两种。当轿厢蹲在缓冲器上就称为蹲底。此时,缓冲器对电梯轿厢的冲击力产生缓解的作用,不至于对电梯内乘客造成严重的伤害。 10、当电梯突然停电或出现故障,被困在轿厢内则应注意些什么? 当您被关在轿厢时,应听从电梯司机的指挥,若无司机的状况下,可通过通讯装置与相关人员联系,以求解救。千万不要用力扒门或自行跳出,以免发生危险。 11、进入轿厢时应注意那些事项?

电梯电器控制原理

电梯电器控制原理 不同的电梯,不论采用何种控制方式,总是按轿厢内指令,层站召唤信号要求,向上或向下起动,起行,减速,制动,停站。 电梯的控制主要是指对电梯原动机及开门机的起动,减速,停止,运行方向,指层显示,层站召唤,轿车内指令,安全保护等指令信号进行管理。操纵是实行每个控制环节的方式和手段。 二.常规继电器控制的典型控制环节 1. 自动开关门的控制线路 自动门机是安装于轿厢顶上,它在带动轿门启闭时,还需通过机械联动机构带动层门与轿门同步启闭。为使电梯门在启闭过程中达到快,稳的要求,必须对自动门机系统进行速度调节。当用小型直流伺服电机时,可用电阻串并联方法。采用小型交流转矩电动机时,常用加涡流制动器的调速方法。直流电机调速方法简单,低速时发热较少,交流门机在低速时电机发热厉害,对三相电机的堵转性能及绝缘要求均较高。 2. 轿内指令和层站召唤线路 轿内操纵箱上对应每一层楼设一个带灯的按钮,也称指令按钮。乘客入轿厢后按下要去的目的层站按钮,按钮灯便亮,即轿内指令登记,运行到目的层站后,该指令被消除,按钮灯熄灭。 电梯的层站召唤信号是通过各个楼层门口旁的按钮来实现的。信号控制或集选控制的电梯,除顶层只有下呼按钮,底层只有上呼按钮外,其余每层都有上下召唤按钮。 3. 电梯的选层定向控制方法 常用的机种如下; 手柄开关定向 井道分层转换开关定向 井道永磁开关与继电器组成的逻辑电路定向 机械选层器定向 双稳态磁开关和电子数字电路定向 电子脉冲式选层装置定向 4. 电梯的定向,选层线路 电梯的方向控制就是根据电梯轿厢内乘客的目的层站指令和各层楼召唤信号与电梯所处层楼位置信号进行比较,凡是在电梯位置信号上方的轿厢内指令和层站召唤信号,令电梯定上行,反之定下行。 方向控制环节必须注意以下几点: 轿内召唤指令优先于各层楼召唤指令而定向。 电梯要保持最远层楼乘客召唤信号的方向运行 在司机操纵时,当电梯尚未启动运行的情况下,应让司机有强行改变电梯运行方向的可能性在检修状态下,电梯的方向控制由检修人员直接持续揿按轿内操纵箱上或轿厢顶上的方向按钮,电梯才能运行,而当松开方向按钮,电梯即停止。 5. 楼层显示线路 乘客电梯轿厢内必定有楼层显示器,而层站上的楼层显示器则由电梯生产厂商视情况而定。过去的电梯每层都有显示,随着电梯速度的提高,群控调度系统的完善,现在很多电梯取消了层站楼层显示器,或者只保留基站楼层显示,到达召唤站时采用声光预报板,如电梯将要到达,报站钟发出声音,方向灯闪动或指示电梯的运行方向,有的采用轿内语音报站,提醒乘客。 6. 检修运行线路

巨人通力某电梯调试全参数

巨人通力电梯调试资料 E1 故障历史记录显示最近的故障情况 E2 清除故障记录重置故障记录,清除内存菜单子菜单功能注 d 驱动故障参看故障代码表菜单子菜单功能注代码含义( 斜体表示默认 侄) 必备11主楼层选择主楼层(1) 楼层号 12控制方式集选方式选择:仁SBC单按钮控制:2=DC下集选:3=FC全集选:4=PB按钮控制 门系统110 开门时间相应普通楼层的内指信号时,从门完全打开至开始关门时的时间(5S) 单位秒( 1 --60) 111 重新开门时间重开门后,从门完全打开至重新开始关门的时间(20) 单位0.1 秒(1 —99) 112激活ADO激活提前开门功能0=关闭:1=激活 113强迫关门如果在一段选定的时间内关门受阻,门将以较慢的速度响蜂鸣关门,此时,只有关门力限制器起作用,强迫关门持续到关门结束,0=关闭;1= 有效;2=NUD 114强迫关门时间限制设置开始强迫关门的时间(20) 单位秒(1--60) 115新内指登记快速关门开门或门已打开时,按下按钮可以缩短开门时间单位0。1 秒。 0=无该功能(0-99) 1 1 6光眼延时设置光眼被挡到重新关门的时间(0-99)20 单位0 。1 秒。 =无该功能(0-99) 117 光眼正常快速关门设置光眼正常后快速关门0=无 1=有 118禁止同时开门A门和B门的开门及同时开门功能仁A门优先;2=B门优先

3=同时 119对穿门轿厢选用对穿门轿厢0=一个门;1=对穿门120门终鸣器为盲人选 择门终鸣器0=关;1=门完全打开时响 121延长开门时间LCECO的输入XC(34: E)的类型0二按钮(DOEB);仁开关带蜂鸣器(DOES);2=^关不带蜂鸣器(DOES); 122DOP类型选择DOP类型0=none;仁DOP CS 泊梯130 泊梯楼层如1-33=2( 群组泊梯) 1 #梯此菜单选择的楼层是第一泊梯楼层(PAM)2#梯此菜单选择的楼层是第二泊梯楼层(PAS)3#梯此菜单应0, 0=0FF, nn=楼层号 131泊梯时开门泊梯时A门与B门的开关情况0二关,1=A门优先,2=B 门优先,3=AB门同时开 132泊梯时间选择电梯在开始泊梯前的空闲时间(30)(1-99) 秒 133泊梯模式选择单台或群组泊梯0=关,1=单梯,2=群组泊梯 134自动从特定楼层派遣电梯空闲电梯将离开此楼层(ADF)功能0二关, nn#旨定楼层 135自动返回特定楼层(ADF)功能将电梯开往此楼层0=回主楼层,nn#旨定楼层 内 旨140允许反向内选允许登陆与电梯运行方向相反的内旨信号,一旦停梯使这些信号开始响应0=关,1=开, 141错误内选删除电梯连续完成两个内旨而无人出入轿厢的情况下删除所有内旨信号0=关,1=开 142内选登记蜂鸣器当内选按亮(登记)时发出一短促声音0=关,1=开 143忽略新外呼为响应运时的外呼而忽略新外呼0=关,1=开 144司机模式选择0:标准1 : ATS HK/ 2: ATS CS 145锁的类型(楼层进出控制)指定LCEOPT勺锁输入信号-锁-的用法0= 关,1:锁内选,2:锁外呼,3:锁内选和外呼 146优先下呼1。。3最多定义3个楼层0=没有,nn二楼层

电梯控制系统分析工作原理

电梯控制系统分析工作原理

————————————————————————————————作者:————————————————————————————————日期:

0引言 一种以电动机为动力的垂直升降机,装有箱状吊舱,用于多层建筑乘人或载 运货物。也有台阶式,踏步板装在履带上连续运行,俗称自动电梯。 服务于规定楼层的固定式升降设备。它具有一个轿厢,运行在至少两列垂直的或倾斜角小于15°的刚性导轨之间。轿厢尺寸与结构形式便于乘客出入或装卸货物。 1 电梯系统工作原理 电梯的安全保护装置用于电梯的启停控制;轿厢操作盘用于轿厢门的关闭、 轿厢需要到达的楼层等的控制;厅外呼叫的主要作用是当有人员进行呼叫时,电梯能够准确达到呼叫位置;指层器用于显示电梯达到的具体位置;拖动控制用于控制电梯的起停、加速、减速等功能;门机控制主要用于控制当电梯达到一定位置后,电梯门应该能够自动打开,或者门外有乘电梯人员要求乘梯时,电梯门应该能够自动打开。 电梯控制系统结构图如图1—1所示: CPU 存储器输出接口PC 主机输入接口轿厢操作盘厅外呼叫 指层器 调整 拖动控制 门机控制 井道装置安全保护 装置

图1-1 电梯控制系统结构图 电梯信号控制基本由PLC 软件实现。输入到PLC 的控制信号有运行方式选 择(如自动、有司机、检修、消防运行方式等)、运行控制、轿内指令、层站召唤、安全保护信号、开关门及限位信号、门区和平层信号等。 电梯信号控制系统如图1—2所示: 图1-2 电梯信号控制系统 2 继电器控制系统 电梯继电器控制系统是最早的一种实现电梯控制的方法。但是,进入九十年 代,随着科学技术的发展和计算机技术的广泛应用,人们对电梯的安全性、可靠性的要求越来越高,继电器控制的弱点就越来越明显。 电梯继电器控制系统存在很多的问题:系统触点繁多、接线线路复杂,且触 点容易烧坏磨损,造成接触不良,因而故障率较高;普通控制电器及硬件接线方法难以实现较复杂的控制功能,使系统的控制功能不易增加,技术水平难以提高; 输出接口PLC 输入接口运行方式选择运行控制信号安全保护信号 内指令信号 外指令信号开关门信号门区平层信号拖动控制系统 呼梯信号指示 楼层显示运行方式指示 开关门控制 呼梯铃

巨人通力电梯图纸说明

巨人通力电梯图纸说明drawing list 图纸目录position number table 代码对照表machinery 曳引机machine room wiring diagrams 机房接线图power supply 电源high voltage 高压controller 控制柜external connections 外部接线group connections 群控接线option interface unit 选项接口shaft wiring diagrams 井道接线图control panel connections 控制柜接线图served top floor 顶层服务楼层specials at top floors 特殊顶层服务楼层sered intermetiate floors 中间服务楼层specials at intermediate floors 特殊中间服务楼层extra long fllor to fllor distance 特殊长间距楼层served first fllor 第一层服务楼层specials at first fllor 特殊第一层服务楼层pit wiring 底坑接线key switches at landings 厅门钥匙开关emergency exits in shaft 井道紧急出口car diring diagrams 轿厢接线图travelling cable 随缆inspection drive 检修运行safety switches 安全开关limit switches 极限开关doors 门car network,cop 轿厢网络,COP car calls 轿内召唤car operating panel,general 轿厢操作面板,通用car operating panel,optional 轿厢操作面板,选项car lighting and ventilation 轿厢照明和通风circuit diagrams 电路图contactor control 接触器控制machinery control 曳引机控制safety chain 安全回路 car,door contacts 轿厢,门触点deceleration switches,position switches 检修运行,位置开关eceleration switches 减速开关load weighing 称重floor computer network 楼层计算机网络door control AMD 门机控制AMD car and shaft light 轿厢和井道照明emergency lighting and alarm 应急照明和警报remote alarm 远程报警optional circuit diagrams 功能选项电路图wiring between option boards 选项板间接线option board 功能选项板monitoring and command system 监控和指令系统firemans drive 消防运行emergency power drive 紧急电源驱动lift announcer 电梯语音报locking of car calls 内呼锁定locking of landing calls 外呼锁定attendant service 司机服务emergency battery drive 紧急电池驱动traffic supervision display 运载流量监察显intercom system 对讲机系统vanes diagram 井道飞器布置图shaft layout,lowest floors 底层井道布置图shaft layout,top floors 顶层井道布置图shaft layout,dummy floors 假楼层井道布置图control panel layout 控制柜布置图shaft electrification panel 井道电器控制柜maintenance access panel 维保控制屏DWG. NO. 图号ISSUE 版本control panel assembly 控制柜总成position number table 代码对照表hoisting motor 曳引马达thermistors 热敏电阻tachome ter 测速发电机brake solenoid 抱闸线圈door zone switch 门区开关

通力KONE3000MS电梯线路分析

通力KONE3000 电梯线路分析 一、主回路(图20-1、图20-2) 1.主回路 网路电源Ll、L2、L3f熔断器Fl、F2、F3f滤波器387-调速驱动电路板385(图20-2)^主电动机M o 2.辅助电路 速度检测信号由脉冲发生器G,即6:2输出与电梯速度成比例的脉冲信号送到驱动电路板385处理后,作为电动机的速度反馈信号。 6:1为相位检测器,检测实际的角速度W和相位差作为变频调速的失量控制参数,提高变频调速的精度和稳定性。1:T为热敏电阻,检测电动机的温度,超温为电动机过载,电梯即刻停车或不得启动。 10(1?M)为逆变器冷却风扇。 11:1J1:2为制动抱闸线圈。 二、群控线路(图20-3) 双机群控时,控制信号732的LCECAN板由端子XG3A及XG3B连接。控制电源731的LCEGTW板由端子XG1A及XG1B连接。DC24V电源723的LCEREC板由XG2A及XG2B连接,电梯选项功能722LCEOPT 板由X5端子相互连接。 三、大厅信号线路(图20-4) 122:2-(T-1)为厅门锁开关触点信号“103:2-(T-l)为大厅下行外呼按钮触点信号及按钮灯信号,104:2-(T-l)为大厅上行外呼按钮触点信号及按钮灯信号,176:2-(T-1)为大厅楼层显示信号及方向显示信号。上述信号经过大厅申行微机板197:2-(T-1),经串行线RS485与控制柜主微机相联系。 四、井道安全值号(图20-5~图20-8) 122:1322.2和122:3为大厅门锁开关触点信号,112:1急停按钮触点信号,123:1涨绳开关触点信号325:1,125:2桥厢缓冲器开关及对重缓冲器开关触点信号,116为输出服务幵关触点信号。 五、轿厢线路(图20-9?图20-15) 图20-9,由控制柜的主微机板375.经端于XC1HXC12与轿厢控制板806相互传送信号及电源:DC24V电源、上下平层信号、门区信号、减速信号、内选串行信号、门安全触板信号、对讲机信号等。 图20-12,由接口板379向轿厢控制板806提供上行按钮42:U信号、下行按钮42:N信号、检修运行按钮42:RB信号、检修运行开美42:DS信号、轿顶应急灯信号44:2、报警按钮39;2信号、轿顶电源擂座45等信号. 图20-13,向轿顶接线盒输入的信号有:轿厢极限开关信号51、安全钳开关信号52、门区开关信号 227

巨人通力电梯调试参数

E1 故障历史记录显示最近的故障情况 E2 清除故障记录重置故障记录,清除内存 菜单子菜单功能注 d 驱动故障参看故障代码表 菜单子菜单功能注代码含义(斜体表示默认值)必备 1-1 主楼层选择主楼层(1)楼层号 1-2 控制方式集选方式选择:1=SBC 单按钮控制:2=DC 下集选:3=FC 全集选:4=PB 按钮控制门系统 1-10 开门时间相应普通楼层的内指信号时,从门完全打开至开始关门时的时间(5S)单位秒(1--60) 1-11 重新开门时间重开门后,从门完全打开至重新开始关门的时间(20)单位0.1 秒(1—99) 1-12 激活ADO 激活提前开门功能0=关闭:1=激活 1-13 强迫关门如果在一段选定的时间内关门受阻,门将以较慢的速度响蜂鸣关门,此时,只有关门力限制器起作用,强迫关门持续到关门结束,0=关闭;1=有效;2=NUD 1-14 强迫关门时间限制设置开始强迫关门的时间(20)单位秒(1--60) 1-15 新内指登记快速关门开门或门已打开时,按下按钮可以缩短开门时间单位0.1 秒。0=无该功能(0-99) 1-16 光眼延时设置光眼被挡到重新关门的时间(0-99)20 单位0.1 秒。0=无该功能(0-99) 1-17 光眼正常快速关门设置光眼正常后快速关门0=无1=有 1-18 禁止同时开门A 门和B 门的开门及同时开门功能1=A 门优先;2=B门优先3=同时 1-19 对穿门轿厢选用对穿门轿厢0=一个门;1=对穿门 1-20 门终鸣器为盲人选择门终鸣器0=关;1=门完全打开时响 1-21 延长开门时间LCECOS 的输入XC(34:E)的类型0=按钮(DOEB);1=开关带蜂鸣器(DOES);2=开关不带蜂鸣器(DOES); 1-22 DOP 类型选择DOP 类型0=none;1=DOP CS泊梯 1-30 泊梯楼层如1-33=2(群组泊梯)1#梯此菜单选择的楼层是第一泊梯楼层(PAM)2#梯此菜单选择的楼层是第二泊梯楼层(PAS)3#梯此菜单应0,0=0FF,nn=楼层号 1-31 泊梯时开门泊梯时A 门与B 门的开关情况0=关,1=A 门优先,2=B门优先,3=AB 门同时开1-32 泊梯时间选择电梯在开始泊梯前的空闲时间(30)(1-99)秒 1-33 泊梯模式选择单台或群组泊梯0=关,1=单梯,2=群组泊梯 1-34 自动从特定楼层派遣电梯空闲电梯将离开此楼层(ADF)功能0=关,nn=指定楼层 1-35 自动返回特定楼层(ADF)功能将电梯开往此楼层0=回主楼层,nn=指定楼层 内指 1-40 允许反向内选允许登陆与电梯运行方向相反的内指信号,一旦停梯使这些信号开始响应0=关,

电梯工作原理及结构图

电梯功能及结构图 一、主要是由控制部分、驱动部分及曳引部分组成。 从以上链接地址中可以看出电梯全部结构的组成,区别于卷扬机的是,它有交互性、有舒适且安全的乘坐空间。 电梯简单理解是这样工作的:它是将动力电能,通过某种变频装置或直接向驱动装置供电,由驱动装置拖动曳引装置,再通过曳引装置上悬挂的钢丝绳拉动井内轿厢做上下运行工作。所有这些动力驱动是由很多的电气装置、机械装置实现整合工作的。 二、为什么电梯在楼上,而在一楼一按它就会下来呀? 电梯停候在上面某层,当一楼按下外召唤时,实际上简单的理解是一个触点开关,按下去的一瞬间,指令通过井内电线传输到控制柜的主控制板(或信号控制板或PC机控制板或最原始的电梯就是继电器动作),我们以控制板为例,它收到瞬间信号以后再次触动控制板内的固有程序,同时由它输出电梯准备如何响应的指令,分别至外呼灯亮及驱动装置,最后电能直接或间接驱使电机带动变速箱转动,通过钢丝绳与曳引轮的摩擦力带动轿厢向下运行,每一层都有一个平层装置来采集电梯所处位置,当电梯快到一楼时,控制板通过程序输出不同信号来控制驱动装置,使电梯换速到1楼平层开门,实现电梯外召指令。 三、为什么在轿厢里按几楼就会在几楼停呀? 工作方法类同于你提到的第二个问题,只是把外召按钮搬到了轿内,工作运行也相同。唯一不同的是轿厢指令起动的程序与外召唤不同,程序是独立的,外召唤有上、下按钮,而轿内的没有上、下之分是直达(除非路过的楼外有同方向召唤指令),站在外面按上及下所响应的结果是不同的,这里我不做详解了,相信楼主经常做电梯有感触,当你要下楼时同时按上、下所得到的电梯响应是有区别的,电梯做的功也不同,不利于节能。 1/ 1

巨人通力电梯调试参数(2014最新)

巨人通力电梯调试资料 E1故障历史记录显示最近的故障情况 E2清除故障记录重置故障记录,清除内存 菜单子菜单功能注 d驱动故障参看故障代码表 菜单子菜单功能注代码含义(斜体表示默认侄) 必备11主楼层选择主楼层(1)楼层号 12控制方式集选方式选择:1=SBC单按钮控制:2=DC下集选:3=FC全集选:4=PB按钮控制 门系统 110开门时间相应普通楼层的内指信号时,从门完全打开至开始关门时的时间(5S)单位秒(1--60) 111重新开门时间重开门后,从门完全打开至重新开始关门的时间(20)单位 0.1秒(1—99) 112激活ADO激活提前开门功能0=关闭:1=激活 113强迫关门如果在一段选定的时间内关门受阻,门将以较慢的速度响蜂鸣关门,此时,只有关门力限制器起作用,强迫关门持续到关门结束,0=关闭;1=有效;2=NUD 114强迫关门时间限制设置开始强迫关门的时间(20)单位秒(1--60) 115新内指登记快速关门开门或门已打开时,按下按钮可以缩短开门时间单位 0。1秒。 0=无该功能(0-99) 116光眼延时设置光眼被挡到重新关门的时间(0-99)20单位 0。1秒。 =无该功能(0-99) 117光眼正常快速关门设置光眼正常后快速关门0=无

1=有 118禁止同时开门A门和B门的开门及同时开门功能1=A门优先;2=B门优先 3=同时 119对穿门轿厢选用对穿门轿厢0=一个门;1=对穿门 120门终鸣器为盲人选择门终鸣器0=关;1=门完全打开时响 121延长开门时间LCECOS的输入XC(34:E)的类型0=按钮(DOEB);1=开关带蜂鸣器(DOES);2=开关不带蜂鸣器(DOES); 122DOP类型选择DOP类型0=none;1=DOP CS 泊梯130泊梯楼层如1-33=2(群组泊梯)1#梯此菜单选择的楼层是第一泊梯楼层(PAM)2#梯此菜单选择的楼层是第二泊梯楼层(PAS)3#梯此菜单应0,0=0FF,nn=楼层号 131泊梯时开门泊梯时A门与B门的开关情况0=关,1=A门优先,2=B 门优先,3=AB门同时开 132泊梯时间选择电梯在开始泊梯前的空闲时间(30)(1-99)秒 133泊梯模式选择单台或群组泊梯0=关,1=单梯,2=群组泊梯 134自动从特定楼层派遣电梯空闲电梯将离开此楼层(ADF)功能0=关,nn=指定楼层 135自动返回特定楼层(ADF)功能将电梯开往此楼层0=回主楼层,nn=指定楼层 内 指140允许反向内选允许登陆与电梯运行方向相反的内指信号,一旦停梯使这些信号开始响应0=关,1=开, 141错误内选删除电梯连续完成两个内指而无人出入轿厢的情况下删除所有内指信号0=关,1=开 142内选登记蜂鸣器当内选按亮(登记)时发出一短促声音0=关,1=开 143忽略新外呼为响应运时的外呼而忽略新外呼0=关,1=开 144司机模式选择0:标准 1:ATS HK/ 2:ATS CS

巨人通力电梯图纸说明

巨人通力电梯图纸说明 Company Document number:WTUT-WT88Y-W8BBGB-BWYTT-19998

巨人通力电梯图纸说明 drawing list 图纸目录 position number table 代码对照表 machinery machine room wiring diagrams 机房 power supply 电源 high voltage 高压 controller external connections 外部接线 group connections 群控接线 option interface unit 选项接口 shaft wiring diagrams 井道 control panel connections served top floor 顶层服务楼层 specials at top floors 特殊顶层服务楼层 sered intermetiate floors 中间服务楼层 specials at intermediate floors 特殊中间服务楼层extra long fllor to fllor distance 特殊长间距楼层served first fllor 第一层服务楼层 specials at first fllor 特殊第一层服务楼层 pit wiring 底坑接线 key switches at landings 厅开关 emergency exits in shaft 井道 car diring diagrams 轿厢接线图 travelling cable 随缆 inspection drive 检修运行 safety switches 安全开关 limit switches 极限开关 doors 门 car network,cop 轿厢网络,COP car calls 轿内召唤 car operating panel,general 轿厢操作面板,通用car operating panel,optional 轿厢操作面板,选项car lighting and ventilation 轿厢照明和通风circuit diagrams contactor control 控制 machinery control 控制 safety chain 安全回路

电梯工作原理

电梯主要安全部件工作原理 电梯:一种以电动机为动力的垂直升降机,装有箱状吊舱,用于多层建筑乘人或载运货物。也有台阶式,踏步板装在履带上连续运行,俗称自动电梯。服务于规定楼层的固定式升降设备。它具有一个轿厢,运行在至少两列垂直的或倾斜角小于15°的刚性导轨之间。轿厢尺寸与结构形式便于乘客入或装卸货物。 电梯的结构包括:四大空间,八大系统 四大空间 机房部分、井道及地坑部分、轿厢部分、层站部分。 八大系统 曳引系统、导向系统、轿厢、门系统、重量平衡系统、电力拖动系统、电气控制系统、安全保护系统 功能 现代电梯主要由曳引机(绞车)、导轨、对重装臵、安全装臵(如限速器、安全钳和缓冲器等)、信号操纵系统、轿厢与厅门等组成。这些部分分别安装在建筑物的井道和机房中。通常采用钢丝绳摩擦传动,钢丝绳绕过曳引轮,两端分别连接轿厢和平衡重,电动机驱动曳引轮使轿厢升降。电梯要求安全可靠、输送效率高、平层准确和乘坐舒适等。电梯的基本参数主要有额定载重量、可乘人数、额定速度、轿厢外廓尺寸和井道型式等。

电梯的基本组成 主要安全部件:限速器、安全钳、缓冲器、制动器

限速器的工作原理 双向限速器结构图 其结构包括:1限速器体,2限速器绳,3限速器绳轮,4左夹绳臂与夹块,5??6离心锤联动拉杆,7触发锁舌,8触发锁舌转轴,9离心锤转轴, 10.离心锤回位接头,11离心锤回位弹簧,12右夹绳臂与夹 块,13限速器绳轮转轴,14制动块销轴,15制动块,16制动块扭簧,17制动块转轴,18触发锁舌扭簧,19花盘销轴,20夹绳臂转轴,21花盘 安全钳

为保证电梯安全运行,从设计、制造、安装等各个环节都要充分考虑到防止危险的发生,并针对各种可能发生的危险,设臵专门的完全装臵。限速器安全钳系统,就是在电梯发生超速和断绳时起保护作用的安全装臵。该系统是否能正常工作,不仅取决于设计制造,更重要的是取决于日常维护保养。 国标GB7588-2003《电梯制造与安装安全规范》中第9.9.1条规定,操纵轿厢安全钳装臵的限速器动作速度应发生在等于额定速度的115%。但应满足:对于额定速度大于1.00m/s 的渐进式安全钳装臵为 1.25m/s+0.25m/s。对于额定速度超

巨人通力电梯公司标准合同协议书图文稿

巨人通力电梯公司标准 合同协议书 集团文件版本号:(M928-T898-M248-WU2669-I2896-DQ586-M1988)

电梯设备买卖合同 合同编号: 项目名 称: 项目所在 地: 用户名称(合格证指定单位): 买方(甲方)卖方(乙方) 单位名称:单位名称:巨人通力电梯有限公司 地址:地址:浙江省湖州市南浔吴越路西侧 电话:电话: (0572)3787957 传真:传真: (0572)3787905 邮编:邮编: 313009 开户银行:开户银行:中国工商银行南浔区支行 银行帐号:银行帐号: 税务登记号: 组织机构代码: 甲方盖章:乙方盖章: 甲方法定代表人或乙方法定代表人或 委托代理人签字:委托代理人签字: 年月日年月日 注:1.可选项中,选择请在该项前的“囗”内划“”或标“■”。 根据《中华人民共和国合同法》的有关规定,经甲、乙双方协商一致,签订本合 同并遵

照执行: 1 设备型号、数量及价格具体规格参数详见附件一 注:1)本合同设备总价已包括电梯设备销售额及运输应交纳的税金。 2)每台电梯对应一个梯名,若同规格电梯有n台,梯名可用L1—Ln表示。 3)甲方应在合同签订时根据所需发票种类向乙方提供开具发票必需的开户银 行、帐号、 税号,乙方在收到上述资料及合同规定的款项后,在货物发运后一周内向甲方开具发票。 4)电梯由乙方办理通过当地技监局验收,所需要的手续和发生费用由甲方承担。 5)适用场所:囗商场囗综合楼囗医院囗交通枢纽囗厂房囗学校 囗住宅■酒店囗其它(项目特殊性的描述): 2 付款方式 2.1在本合同签订之日起 10 天内,甲方向乙方支付本设备总价款的%(第一期 款)作为定金,计人民币元(大写):元整,直接付至本合同乙方指定的帐户。甲方逾期给付的,则合同交货期予以顺延。若合同履行,则定金抵作本合同的货款。

电梯原理结构(全)

电梯原理结构 电梯的基本结构是:一条垂直的电梯井内,放置一个上下移动的轿箱(Cab)。电梯井壁装有导轨,与轿箱上的导靴限制轿箱的移动。轿箱的支撑及升降有两种方法: 曳引式 多条钢缆,把轿箱悬挂在电梯井顶部机房的曳引轮之上。钢缆另一端悬挂作平衡的对重。对重一般为轿箱加上50%负载时的重量。当轿箱移动时,对重会向反方向移动。曳引轮是依靠钢缆的粗糙表面及引轮上坑纹之间的摩擦力来拉动轿箱。因此当钢缆或曳引轮用旧之后,必须适时更换以防滑溜。电动机负责带动曳引轮转动,提供动力升起或放下轿箱。电动机可能是交流,亦有可能是直流。部分电动机要使用齿轮带动曳引轮,较新及较快的电梯一般会采用无齿轮带动。部分高层曳引式电梯还有重量补偿:在轿箱及对重之下设有一条钢缆或锁链,连接到地上。作用是补偿悬挂轿箱或对重的钢缆长度改变引起的重量变化。曳引式电梯必定会有各种安全装置,防止轿箱因钢缆继裂、制动失灵等任何原因造成的堕落。最低限度的安全装置包括:在机房装设的钢缆限速器,在轿箱及对重上安装安全钳。安全钳即奥的斯当年发明的机械安全装置,当加速到某一速度时会自动钳紧导轨,把轿箱或对重刹停。在电梯井的底部,还会装有缓冲器,作为最后的保护。 曳引式电梯一般需要在电梯顶部设置机房。近年设计新型的曳引式电梯,采用纤维-钢缆复合缆索,可以减少所需的润滑及维修。此外新型的电动机体积小,可以安装在井壁,免除机房设置。 液压式 轿箱由底下的柱塞支撑及升降,柱塞由液压推动。部分柱塞可作望远镜式折叠,减少地底所需要的深度。部分柱塞不可折,安装时地下必需挖一个洞。因为柱塞的限制,液压式电梯一般只会在两至五层高的建筑物上使用(不多于20米)。液压式电梯的优点是机房可设置在任何位置,而且占地较少,机械亦较为简单;一般使用亦较少机会发生问题。但是亦有耗电较多,速度低的缺点(秒速不高于1米)。 电梯原理结构分章(点击进入查看相关内容) 第一章:电梯的型号与分类 第二章:电梯结构原理与安全保护装置 第一节:曳引系统 第二节:轿厢与门系统 第三节:导向系统 第四节:重量平衡系统 第五节:电气控制装置 第六节:电梯安全保护装置 第三章:继电器逻辑控制电梯系统 第一节:呼叫指令的记忆与解除 第二节:选层器 第三节:自动定向电路 第四节:最远的反向呼叫电路 第五节:电梯的启动与换速电路 第六节:平层停止运行电路 第七节:开关门控制电路