当前位置:文档之家› Solenoid_Valves_Parker2

Solenoid_Valves_Parker2

Solenoid_Valves_Parker2
Solenoid_Valves_Parker2

Solenoid Valves - Operating Principles

Series 117

Series 117

?O D M

A B

C

D

Series 127

Series 127

?O D M

A

B

?C

D

?O D F

B

D

Dwg. 1

Dwg. 2

Series 112

Series 112

?S A E

A

B

C

D

?O D F

B

D

Dwg. 1

Dwg. 2

Series 115

Series 115

?S A E

A

B

C

D

?O D F

B

D

Dwg. 1

Dwg. 2

Series 142

Series 142

?S A E

A

B

C

D

?O D F

B

D

Dwg. 1

Dwg. 2

Series 145

Series 145

?S A E

A B C

D

?O D F

B

?C

D

Dwg. 1

Dwg. 2

Series RB

Series RB

?O D F

A C

B

D

Series ORB

Series ORB

?O D F

A C

B

D

RT Coil

Coil manufactured from class H copper wire, moulded in

thermoplastic

- (polyester) with 30% glass fiber

- Anti-moisture aggression seals with plastic nut.

Features:

Protection DIN 40050 = IP 65 with connector

Connector DIN 43650 A - PG 9 or PG 11

Frequency50/60 Hz

Types available:

Class F (155O C)

RT 14 = 25 VA - 14 W a.c. Service (33 VA - Inrush)

IMQ approval

Y Coil

Coil manufactured from class H copper wire, moulded in

thermoplastic (polyester) with 30% glass fiber

Features:

Protection DIN 40050 = IP 67

Electrical Connector two 1000mm cables

Frequency50/60 Hz

Types available:

*IMQ, VDE, UL approved for standard voltages

1)Class F (155O C)

YB14 =24 VA - 14 W a.c. Service (32 VA - Inrush)

YB09 =15 VA - 9 W a.c. Service (24 VA - Inrush)

YB12 =12 W d.c.

YB16 =16 W d.c.

2)Class E (120O C)

YEO9 = 15 VA - 9 W a.c.

Note: Recommended for applications where humidity is

particularly severe and where ice formation or defrosting

may occur.

ZB Coil

CD Coil

Coil manufactured from class H copper wire, moulded in thermoplastic:

- (polyester) with 30% glass fiber - Anti-moisture aggression seals

- Special DC adaptor for higher performance

Features:

Protection

DIN 40050 = IP 65

Electrical Connector

DIN43650A - PG 9 or PG 11

Types available:

1)Class F (155O C)

CD21 = 21 W d.c.

Coil manufactured from class H copper wire, moulded in thermoplastic

- (polyester) with 30% glass fiber (type ZB);

- (polyphenylene) with 40% glass fiber (type ZH)

Features:

Protection DIN 40050 = IP 65 with connector Connector DIN 43650 A - PG 9 or PG 11Frequency

50/60 Hz

Types available:

*IMQ, VDE, UL approved for standard voltages 1)Class F (155O C)

ZB14 =25 VA - 14 W a.c. Service (33 VA - Inrush)ZB09 =16 VA - 9 W a.c. Service (25 VA - Inrush)ZB12 =12 W d.c.ZB16 =16 W d.c.2)Class H (180O C)

ZH14 = 25 VA - 14 W a.c. - Service (33 VA - Inrush)

ZH16 = 16 W d.c.

Metric Extended Capacities in Kilowatts

相关主题
文本预览
相关文档 最新文档