当前位置:文档之家› EMERSON美国产品样本 2004

EMERSON美国产品样本 2004

Page Thermal Expansion Valves1 A-Series2

AFA Series5

HFK Series7

HF Series10

TRAE+ Valve16

TRAE Valve17

T-Series19

TLE Valve23

TI Valve25

ZZ Valve26

LCL Valve28

ESVB Valve30

EX2 Valve32

ACP(E) Valve34 Solenoid Valves58 50RB59

100RB60

200RB62

240RA65

500RB67

540RA69

710/713RA71

702RA73

207CB*74

3031RB/RC76

RV Series*78

703RC80 Coils85 Industrial Solenoid Valves88 202C*89

203C*91

204C*93

210C/211C*95

214C*97

222C*99

314U*101 Shut Off Valves

ABV104

RD105

ACK*134 System Protectors106 EK109

EKP110

ADK112

BFK114

BOK-HH116

ALF*118

CU - Spun Copper Service Drier*119

CU - Spun Copper Liquid Line Drier*120

STAS121

ADKS122

E MERSON C LIMATE T ECHNOLOGIES INDEX *Also Included in the Extended Products Catalog

Page Blocks and Cores125

BTAS*126

ASD128

SFD129

CSFD130

ASK-HH131

ASF132

APD133

ACK*134

HMI135

AMI136

A-IHL138

A-IHN138 Storage Devices

A-AS*145

AVR*147

AOR*148 Oil Controls

W-OLC*149

OMB*150

A-W/A-F*151

High Efficiency Oil Separator152

AOFD*153

ASF*153

AOF*154

AAU155 Regulators156 ESR157

MTB 1158

IPR159

EPRB(S)160

OPR162

ACP(E)163

EGR(E)165

DGR(E)167

CPH(E)168

HP/HPC170 Temperature Pressure Controls183 TS1184

PS1188

PS2190

FD113192

PS3193

FS196

FF4198

FF444199 Troubleshooting Guide200 Competitive Cross Reference207 INDEX Also Included in the Extended Products Catalog

E MERSON C LIMATE T ECHNOLOGIES

Alpha Numeric By Product

Product Page 50RB59 100RB60 200RB62 202C*89 203C*91 204C*93 207CB*74 210C/211C*95 214C*97 222C*99 240RA65 314U*101 500RB67 540RA69 703RC80 710/713RA71 3031RB/RC76 A-Series2

A-AS*145 AAU155 ABV*104 ACK*134 ACP(E)34 ADK112 ADKS122 A-F*151 AFA5

A-IHL138 A-IHN138 ALF*118 AMI136 AOF*154 AOFD*153 AOR*148 APD133 ASD126 ASF132 ASF*153 ASK-HH131 AVR*147 A-W*151 BFK114 Blocks and Cores125 BOK-HH116

Product Page

BTAS*126

Coils85

CPH(E)168

CSFD130

CU - Liquid Line*121

CU - Service Drier*120

DGR(E)167

EGR(E)165

EK109

EKP110

EPRB(S)160

ESR157

ESVB32

EX234

FD113192

FF4198

FF444199

FS196

HF10

HFK7

HMI135

HP/HPC170

IPR159

LCL28

MTB 1158

OMB*150

OPR162

OS152

PS1188

PS2190

PS3193

RD105

RV*78

SFD129

STAS121

T-Series19

TI25

TLE23

TRAE17

TRAE+16

TS1184

W-OLC*149

ZZ26

E MERSON C LIMATE T ECHNOLOGIES INDEX

*Also Included in the Extended Products Catalog

E MERSON C LIMATE T ECHNOLOGIES

1

STYLE NOMINAL REPLACEABLE

CONNECTIONS CONFIGURATION PORT

CAPACITY VALVE CATALOG SERVICE POWER FIELD ADJUSTABLE INTERNAL

APPLICATION

(R-22)

FAMILY

PAGE

REPLACEMENT HERMETIC ELEMENT ASSEMBLED

SAE

ODF

ANGLE

STRAIGHT CONVENTIONAL BALANCED SUPERHEAT CHECK

1/4 to 5AA 2X X X X X 1/4 to 5AN 2X X X

X X 1/4 to 5AAC 4X

X X X X X X 1/4 to 5ANC 4X X

X X

X X

1/4 to 5AFA 5X X

X X X X 1/3 to 5TI 25X X

X X

X

X

1/4 to 5 1/2

HFK 7X X X

X X X X X X AIR 1/4 to 5 1/2HF 10X X

X X X X X CONDITIONING 8 to 20HF EXT 10X

X X X X

X AND

1/2 to 12TL 23X X X X X X REFRIGERATION 1/2 to 12

TCL 19X X X

X X X X X 11 and 14TJL 19X X X X X X

X

14 and 18TJR 19X X X X X X X 22 to 45TER 19X X X X X X X 55TIR 19X X X X X X X 70 and 85THR 19X X X X X X X 100TMR 19X

X X X X X 10 to 40TRAE+16X

X X X X 50 to 70

TRAE 17X X X X

X CONSTANT PRESSURE

1/2 to 5ACP 34X X X

X ELECTRICALLY 1 to 20ESVB 30X X X N/A N/A DRIVEN

1/4 to 4EX232X

X X N/A N/A ULTRA-LOW TEMP

3/4 to 8

ZZ 26X X X X X X X De-Superheating

LCL

28

X

X X

X X

X X

T HERMAL E XPANSION V ALVE Q UICK S ELECT G UIDE AND C HARGE C ODE S ELECTOR

-50-40-30

-20-1001020304050

E MERSON C LIMATE T ECHNOLOGIES

2

A

A

C

E

B

2

H C 30 IN 3/8 x 1/2ODF ANG

V alve Superheat Adjustment Internal Equalizer Bleed Hole Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series Check (optional)Nominal Rating Code Code T ube

Connection T ype uration Economy, A = Adjustable V alve E=External in Tons F = R12

Length Sizes SAE =Hermetic (optional)Omit for H = R22 C = medium temp I O flare S/T =Design

N = Non-Adjustable

Reverse (Omit for no bleed See nominal M = R134a CA = heat pump 30 IN (std)1/4 3/8ODF =straight-Flow Internal)

hole

capacity N = R407C W(MOP)=press. limiting other 3/8 1/2solder thru Bypass table P = R507Z = low temp lengths are 1/2 5/8Chatleff Application

below

R = R502AA = wide range available 5/8 7/8(optional)ANG =

S = R404A Aeroquip 90°Z = R410A (optional)angle

Hermetic construction eliminates external leakage Compact size allows installation in limited spaces

Mass spectrometer tested to ensure less than 0.10 oz/year external leakage rate

Stainless steel power element eliminates corrosion and prevents valve failure

F EATURES

S PECIFICATIONS

Maximum working pressure:700 psig UL Recognized:SA 5312

“A” Series Thermo Expansion Valves are used for heat pump,air conditioning, food service and commercial applications.“A” Series valves provide stable and accurate control over a wide range of operating conditions.

N OMENCLATURE EXAMPLE : AACEB 2 HC 30 IN 3/8 X 1/2 ODF ANG

HAA wide range charge allows two valves ( 2 1/2 and 5 ton, R-22) to cover all capacities from 1 to 5 tons on most residential systems

New ZW195 charge available for R-410A systems Available adjustable or non-adjustable superheat for application flexibility

SAE or ODF connections standard – chatleff or aeroquip are available

Available external or internal equalizer to satisfy the broadest possible range of applications

Available internal check valve allows reverse flow heat pump applications, eliminating the need for external piping and external check valve, thus reducing installation costs (ANC Series)

Bleed type pressure equalization available to accommodate PSC type compressors

Pressure limiting charges (MOP) available – consult factory

O PTIONS

Extended Capacity Tables begin on page 36.Ordering Information begins on page 3.

R12

R134a

R22

R410A

R502

R507/R404A

R407C

1/81/5––1/81/51/81/41/41/41/81/41/41/41/21/21/21/41/21/21/23/4111/23/41111?1?111?–1?22–1?21?22?31?22?22?3422?3?2?3452?2?43

4

5

3

3?

5?

AA/AN S ERIES – N OMINAL C APACITY T ABLE IN T ONS

Standard Product Offering* Product Code Number S/T = Straight Through

E MERSON C LIMATE T ECHNOLOGIES3

E MERSON C LIMATE T ECHNOLOGIES

4

V A L LV V E C A P A C I T Y

P C

N* C HA R G E GE

C A P

S E R I E S

T O N S

C O N N E C T I O N S

C F H C A H W 100

T U B E

R -12/R -134-134a

a M E D . T E M P .R -22 H E A T P U M P

R-22 MOP

23/8 X 1/2 ODF ANG 00750630 IN.2 1/2

3/8 X 1/2 ODF ANG

007507

30 IN.

U NIVERSAL R EPLACEMENT

HAA AND ZW195 W IDE R ANGE C HARGE FOR HVAC A PPLICATIONS

The AACE wide range valve allows several TXV to replace the majority of residential air conditioning and heat pump applications.

Special high stability charges designed for HVAC applications and used by leading original equipment manufacturers. These wide range charges provide greater superheat stability,allowing in most cases two valves to cover a wide range of capacities from 1 to 5 tons.

Offers customers the benefit of inventory reduction by replacing several valves with two valves, while continuing to meet system performance needs.

With the addition of an integral check valve, four expansion valves can meet the majority of residential HVAC, light

commercial, and heat pump applications as shown in Table 1.

T ABLE 1

SUPERHEAT SCREW REPLACEMENT KIT 20297

AACE D IMENSIONAL D ATA

O RDERING I NFORMATION FOR A-S ERIES V ALVES

ANEB

E MERSON C LIMATE T ECHNOLOGIES

5

External superheat adjustment Replaceable inlet strainer SAE connections only

Wrench flats on inlet and outlet for easy installation Stainless steel power element for maximum corrosion resistance

F

EATURES

The AFA series Thermo ? Expansion Valve is designed for air conditioning and commercial refrigeration applications requiring angle configuration SAE connections. The AFA is ideal for those applications requiring compact size com-bined with stable and accurate control over wide load and evaporator temperature ranges.

For Ordering Information, see page 6.

Maximum working pressure:700 psig

UL Recognized:

SA 5312S PECIFICATIONS

Available external or internal equalizer to satisfy the broadest possible range of applications

O PTIONS

AF

A

E

1/2

H

C

5 FT

3/8 x 1/2

SAE

ANG

V alve

Superheat Adjustment Equalizer Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series Nominal Rating Code Code T ube Connection T ype uration Economy, A = Adjustable

E=External in Tons F = R12Length Sizes Hermetic H = R22 C = medium temp SAE =ANG =Design

(Omit for See nominal M = R134a CA = heat pump 30 IN 1/4 x 3/8flare

90°Internal)

capacity N = R407C W(MOP)=press. limiting

and 3/8 x 1/2

angle

table P = R507Z = low temp 5 FT (below)

R = R502AA = wide range

are standard

S = R404A Z = R410A

N OMENCLATURE EXAMPLE : AFAE 1/2 HC 5 FT 3/8 X 1/2 SAE ANG R12

R134a

R22

R410A

R502

R507/R404A

R407C

–1/81/5––1/81/51/81/41/41/41/81/41/41/41/21/21/21/41/21/21/23/4111/23/41111?1?111?–1?22–1?21?22?31?22?22?3422?3?–3–5–2?43

4

5

3

3?

5?

AFA S ERIES – N OMINAL C APACITY T ABLE IN T ONS

AFA(E) CONNECTIONS

TOLERANCE

± 5/32 (.16)± 1/32 (.03)

± 3/64 (.05)

I N L E T O U T L E T A B

C 3/81-41/641/41/21-49/641-3/32

1-23/64elbow 5/81-63/643/8 – 1/21-47/643/81-41/643/81/21-41/641-5/16

1-23/64elbow

5/81-63/643/8 – 1/2

1-47/64

AFA(E) D IMENSIONAL D ATA

Remote Bulb Tubing Length 30” or 5’ Standard

DIMENSIONS SHOWN ARE IN

INCHES:

FRACTIONS (DECIMAL)

O RDERING I NFORMATION FOR AFA S ERIES V ALVES

Standard Product Offering* Product Code Number

6

E MERSON C LIMATE T ECHNOLOGIES

E MERSON C LIMATE T ECHNOLOGIES

7

O PTIONS

ODF or SAE connections

Straight-through or angle flow configurations Removable inlet strainer available (ODF only)

Internal or external equalizer

SAE

1/4 thru 5-1/2 tons

R 22

ODF

LENGTH

D IMENSIONAL D ATA

DIA.

O D F

w/optional strainer at inlet

LENGTH

DIA.

Remote Bulb Tubing Length 5’ Standard

Maximum working pressure: 450 psig Operating Temperature: -40°F to 50°F

Use with R-22, R-134a, R-404A, R-507, R-12, R-502S PECIFICATIONS

O D F

Top V iew

Showing External Equalizer Location

HFK

E

S

C

2

H

C

5 FT

3/8 x 1/2ODF S/T

V alve Equalizer Connection R emovable Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series

T ype Inlet Nominal Rating Code Code

T ube Connection T ype uration E=External S=Solder Strainer in Tons F = R12Length

Sizes (optional)H = R22 C = medium temp See Body SAE =S/T =(Omit for (Omit for See nominal M = R134a CA = heat pump 5 FT (std)Table on flare straight-Internal)

SAE C=Inlet capacity N = R407C W(MOP)=press. limiting other

page 23thru

Flare)

Strainer table

P = R507Z = low temp lengths are

ODF =(ODF only)

R = R502available

solder ANG =

S = R404A

90°angle

N OMENCLATURE EXAMPLE : HFKESC 2 HC 5 FT 3/8 X 1/2 ODF S/T

F EATURES

The HFK features interchangeable bodies, cages, and power elements providing maximum flexibility for ? to 5? ton applications (nom. R-22). The HFK is offered several ways:

Pre-packaged service kits – Include a mix of bodies and power elements with a complete set of cages to serve the most applications with a minimum of parts. Individual components - Bodies, cages, & power elements may be ordered separately and can be used to build personalized service kits or replenish pre-packaged kits.

Finished valves – Assembled valves ready for immediate installation.

All HFK valves use a balanced port cage design that compensates for changes in operating pressures due to varying ambients, gas defrost, heat reclaim, or widely varying evaporator loads.

The HFK offers the following additional features:

Bi-Flow capability

Stainless steel power element Adjustable superheat Solid copper connections

DIMENSIONS SHOWN ARE IN

INCHES:

FRACTIONS (DECIMAL)

Refrigerant Charge

L e n g t h D i a.C, Z 3-1/21/2CA

2-5/16

3/4

Remote Bulb Dimensions

HFKESC

ODF C ONNECTIONS

R EPLACEMENT S CREEN K IT KT20264

NOTE :HFK cages are not interchangeable with HF valve

bodies. Power elements can be interchanged.

HFK B ALANCED P ORT TEV

Cage Capacity T

Cage Capacity Table (Nominal) Cage

Code R-12R-22

01/8?

1??

2?

311?

41?

51?2?

P ower Element T

ower Element Table

able1

PCN*Description

Description System Refrigerant(s)

System Refrigerant(s) Application X26300-FW15-1R-12/R-134a L ow T emp MOP

X26300-FW35-1R-12/R-134a L ow T emp MOP

X26300-FW55-1R-12/R-134a L ow T emp MOP

X26300-MC-1R-134a Medium T

X26300-HW100-1R-22/R-407C AC MOP

X26300-HCA-1R-22/R-407C Heat Pump

HFK S ELECTION P ROCESS

Step 1: Body Selection

E MERSON C LIMATE T ECHNOLOGIES 8

HFK B ALANCED P ORT TEV (PCN 065135)

E MERSON C LIMATE T ECHNOLOGIES

10F EATURES

HFESC

ODF C ONNECTIONS

O PTIONS

Large, removable power element

Balanced port construction compensates

for changes in operating pressures due to varying ambients, gas defrost, heat reclaim, or widely varying evaporator loads

Two body sizes provide capacities from 1/4 to 20 tons Bi-Flow capability up to 5-1/2 tons R22 allows one valve to control the superheat in both cooling and heating modes for package unit heat pump applications Wrench flats on inlets and outlets (SAE only) for easy installation

Stainless steel power element for maximum corrosion resistance

Bleed type pressure equalization available to accomodate P SC t ype c ompressors ODF or SAE connections Removable strainer

Adjustable or non-adjustable superheat

SAE

LENGTH

DIA.

1/4 thru 5-1/2 tons R22

ODF

LENGTH

D IMENSIONAL D ATA

DIA.

ODF

w/optional strainer at inlet

LENGTH

DIA.

R EMOTE B ULB T UBING L ENGTH 5’ S TANDARD

Maximum W orking P ressure: 450 p sig Operating Temperature: -40°F to 50°F 5' capillary tube length (standard)

Use with R-22, R134a, R-404A, R-507, R-12, R-502

S PECIFICATIONS

Refrigerant Charge

L e n g t h D i a.C, Z 3-1/21/2CA

2-5/16

3/4

Remote Bulb Dimensions

ODF Top V iew

Showing External Equalizer Location

R EPLACEMENT S CREEN K IT

KT20264

HF

N E S C

B

2

H C 5 FT 3/8 x 1/2ODF S/T

V alve Superheat Equalizer Connection R emovable Bleed Hole Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series

Adjustment T ype

Inlet (optional)Nominal Rating Code Code T ube

Connection T ype uration

E=External S=Solder

Strainer in Tons F = R12

Length Sizes N = Non-(optional)Omit for H = R22 C = medium temp I O SAE =S/T =Adjustable (Omit for (Omit for

no bleed See nominal M = R134a CA = heat pump 5 FT (std)1/4 3/8flare straight-Internal)SAE

C=Inlet hole

capacity *P = R507W(MOP)=press. limiting other 3/8 1/2thru Omit for Flare)Strainer table *R = R502Z = low temp lengths are 1/2 5/8ODF =Adjustable (ODF only)

(on page 17)

*S = R404A available

5/8 7/8solder ANG =

90°angle

N OMENCLATURE EXAMPLE : HFNESCB 2 HC 5 FT 3/8 X 1/2 ODF S/T

DIMENSIONS SHOWN ARE IN INCHES:

FRACTIONS (DECIMAL)

* P , R and S charges are interchangeable

Extended Capacity Tables begin on page 43.Ordering Information begins on page 12.

NOTE :If the HF body is stamped HFK, then the valve has

replaceable components.

E MERSON C LIMATE T ECHNOLOGIES 11

HF D IMENSIONAL D IAGRAM

External Equalizer

E

F

3/16 ODF .192 ± .002.31 ± .031/4 ODF

.254 ± .002

.33 ± .03

R EPLACEMENT P OWER A SSEMBLIES

R12 P OWER POWER A SSEMBLY

R22 P OWER POWER A SSEMBLY

R502 P OWER POWER A SSEMBLY

X26300-FC-1

X26300-HC-1

X26300-RC-1

X26300-FZ-1X26300-HZ-1X26300-RZ-1X26300-FW15-1X26300-HW35-1X26300-RW45-1X26300-FW35-1

X26300-HW65-1

X26300-RW65-1

INLET/OUTLET C ONNECTIONS SIZE O DF C ± .002

D ± .03

1/2.504.375/8.629.507/8.879.761-1/8 1.129.901-3/8

1.379

.97

ODF Top V iew Showing External Equalizer

Location

Refrigerant Tube Length

Dia.

Charge Length dimension

dimension

CA

10 FT.2-5/163/45 FT.10 FT.

C, Z – WMOP

ODF

8, 10, 15 & 20 ton R-22 V alve

3-1/2

1/2

LENGTH

DIA.

HF B ALANCED P ORT TEV

Remote Bulb Tubing Length 5’ Standard

R12

R134a

R22

R502

R507/R404A

1/81/41/41/81/81/41/21/21/41/41/23/411/21/2111?11–1?2––1?1?2?1?1?22?3223?45?3?3?5685567?107791115101012

14

20

13

13

HF S ERIES – N OMINAL C APACITY T ABLE IN T ONS

T SAE l C

O RDERING I NFORMATION FOR HF S ERIES V ALVES

12

E MERSON C LIMATE T ECHNOLOGIES

O RDERING I NFORMATION FOR HF S ERIES V ALVES(CONT’D)

MERSON LIMATE ECHNOLOGIES

O RDERING I NFORMATION FOR HF S ERIES V ALVES(CONT’D)

(CONT’D)

14

E MERSON C LIMATE T ECHNOLOGIES

O RDERING I NFORMATION FOR HF S ERIES V ALVES(CONT’D)

Standard Product Offering* Product Code Number

E MERSON C LIMATE T ECHNOLOGIES15

E MERSON C LIMATE T ECHNOLOGIES

16TRAE Nominal

Sizes (ODF)Inlet Outlet V alve T alve Type ype

Inlet (B)Outlet (E)A C D F 5/87/8 1.570.50 2.090.755/81-1/8 1.570.50 2.210.91TRAE+7/87/8 2.090.75 2.09

0.7510-40

7/81-1/8 2.090.75 2.210.91TONS

7/81-3/8 2.090.75 2.390.971-1/81-1/8 2.210.91 2.210.971-1/81-3/8 2.210.91 2.390.971-1/8

1-3/8

2.21

0.91

2.39

0.97

The TRAE Plus thermostatic expansion valve (TXV) is a large capacity series designed for refrigeration, air condi-tioning, heat pump, and chiller applications. The new series introduces a new replaceable stainless steel power element, a fully interchangeable cage assembly and a square body.

This valve type features double balanced port design, which provides stable and accurate control over wide loads and evaporator temperature ranges. Furthermore, a permanent inlet strainer and external adjustment are standard on every valve.

F EATURES

Suitable for Bi-Flow applications.

Removable power element and cage assembly for full serviceability.

Stainless steel power element for enhanced corrosion resistance

Double balanced port design improves operation and stability under low load conditions.

Square body with straight-thru connections. Solid copper connections. External superheat adjustment.

Large diaphragm provides superior stability HCA charge designed especially for R22 air conditioning applications.

S PECIFICATIONS

Ratings from 10 to 40 tons.

Maximum working pressure: 450 psig Torque Power Assembly: 375 - 425 in. lb. Torque Cage: 60 in. lb.

IMENSIONAL

ATA (INCHES )

TRA

E

+

30

H

C

10 FT

7/8 x 11/8

ODF

S/T

V alve Equalizer R eplaceable Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series

Components Nominal Rating Code Code T ube Connection T ype uration E=External in Tons F = R12Length Sizes 1/4” SAE

Cage and H = R22 C = medium temp I O ODF = solder S/T =Power See nominal M = R134a CA = heat pump 10 FT 5/8 7/8(Only)

Straight-Assembly

capacity N = R407C W(MOP)=press. limiting

(standard)7/8 11/8thru table P = R507Z = low temp

11/8 13/8

(Only)

(below)

R = R502Other S = R404A

lengths are available

N OMENCLATURE EXAMPLE : TRAE+ 30 HC 10 FT 7/8 X 11

/8

ODF S/T

O PTIONS

Cages KT20289 thru KT20293

Remote Bulb Tubing Length 10’ standard,other lengths are available

Replaceable Power Assembly X-28458

R12

R134a

R22

R502

R507/R404A

R407C

7?910881010131512121512142014142018223020203025

30

40

30

30

40

TRAE+ S ERIES – N OMINAL C APACITY T ABLE IN T ONS

TRAE+ and TRAE Series Extended Capacity Tables begin on page 43 in

Tons. For Ordering Information, see page 18.