Page Thermal Expansion Valves1 A-Series2
AFA Series5
HFK Series7
HF Series10
TRAE+ Valve16
TRAE Valve17
T-Series19
TLE Valve23
TI Valve25
ZZ Valve26
LCL Valve28
ESVB Valve30
EX2 Valve32
ACP(E) Valve34 Solenoid Valves58 50RB59
100RB60
200RB62
240RA65
500RB67
540RA69
710/713RA71
702RA73
207CB*74
3031RB/RC76
RV Series*78
703RC80 Coils85 Industrial Solenoid Valves88 202C*89
203C*91
204C*93
210C/211C*95
214C*97
222C*99
314U*101 Shut Off Valves
ABV104
RD105
ACK*134 System Protectors106 EK109
EKP110
ADK112
BFK114
BOK-HH116
ALF*118
CU - Spun Copper Service Drier*119
CU - Spun Copper Liquid Line Drier*120
STAS121
ADKS122
E MERSON C LIMATE T ECHNOLOGIES INDEX *Also Included in the Extended Products Catalog
Page Blocks and Cores125
BTAS*126
ASD128
SFD129
CSFD130
ASK-HH131
ASF132
APD133
ACK*134
HMI135
AMI136
A-IHL138
A-IHN138 Storage Devices
A-AS*145
AVR*147
AOR*148 Oil Controls
W-OLC*149
OMB*150
A-W/A-F*151
High Efficiency Oil Separator152
AOFD*153
ASF*153
AOF*154
AAU155 Regulators156 ESR157
MTB 1158
IPR159
EPRB(S)160
OPR162
ACP(E)163
EGR(E)165
DGR(E)167
CPH(E)168
HP/HPC170 Temperature Pressure Controls183 TS1184
PS1188
PS2190
FD113192
PS3193
FS196
FF4198
FF444199 Troubleshooting Guide200 Competitive Cross Reference207 INDEX Also Included in the Extended Products Catalog
E MERSON C LIMATE T ECHNOLOGIES
Alpha Numeric By Product
Product Page 50RB59 100RB60 200RB62 202C*89 203C*91 204C*93 207CB*74 210C/211C*95 214C*97 222C*99 240RA65 314U*101 500RB67 540RA69 703RC80 710/713RA71 3031RB/RC76 A-Series2
A-AS*145 AAU155 ABV*104 ACK*134 ACP(E)34 ADK112 ADKS122 A-F*151 AFA5
A-IHL138 A-IHN138 ALF*118 AMI136 AOF*154 AOFD*153 AOR*148 APD133 ASD126 ASF132 ASF*153 ASK-HH131 AVR*147 A-W*151 BFK114 Blocks and Cores125 BOK-HH116
Product Page
BTAS*126
Coils85
CPH(E)168
CSFD130
CU - Liquid Line*121
CU - Service Drier*120
DGR(E)167
EGR(E)165
EK109
EKP110
EPRB(S)160
ESR157
ESVB32
EX234
FD113192
FF4198
FF444199
FS196
HF10
HFK7
HMI135
HP/HPC170
IPR159
LCL28
MTB 1158
OMB*150
OPR162
OS152
PS1188
PS2190
PS3193
RD105
RV*78
SFD129
STAS121
T-Series19
TI25
TLE23
TRAE17
TRAE+16
TS1184
W-OLC*149
ZZ26
E MERSON C LIMATE T ECHNOLOGIES INDEX
*Also Included in the Extended Products Catalog
E MERSON C LIMATE T ECHNOLOGIES
1
STYLE NOMINAL REPLACEABLE
CONNECTIONS CONFIGURATION PORT
CAPACITY VALVE CATALOG SERVICE POWER FIELD ADJUSTABLE INTERNAL
APPLICATION
(R-22)
FAMILY
PAGE
REPLACEMENT HERMETIC ELEMENT ASSEMBLED
SAE
ODF
ANGLE
STRAIGHT CONVENTIONAL BALANCED SUPERHEAT CHECK
1/4 to 5AA 2X X X X X 1/4 to 5AN 2X X X
X X 1/4 to 5AAC 4X
X X X X X X 1/4 to 5ANC 4X X
X X
X X
1/4 to 5AFA 5X X
X X X X 1/3 to 5TI 25X X
X X
X
X
1/4 to 5 1/2
HFK 7X X X
X X X X X X AIR 1/4 to 5 1/2HF 10X X
X X X X X CONDITIONING 8 to 20HF EXT 10X
X X X X
X AND
1/2 to 12TL 23X X X X X X REFRIGERATION 1/2 to 12
TCL 19X X X
X X X X X 11 and 14TJL 19X X X X X X
X
14 and 18TJR 19X X X X X X X 22 to 45TER 19X X X X X X X 55TIR 19X X X X X X X 70 and 85THR 19X X X X X X X 100TMR 19X
X X X X X 10 to 40TRAE+16X
X X X X 50 to 70
TRAE 17X X X X
X CONSTANT PRESSURE
1/2 to 5ACP 34X X X
X ELECTRICALLY 1 to 20ESVB 30X X X N/A N/A DRIVEN
1/4 to 4EX232X
X X N/A N/A ULTRA-LOW TEMP
3/4 to 8
ZZ 26X X X X X X X De-Superheating
LCL
28
X
X X
X X
X X
T HERMAL E XPANSION V ALVE Q UICK S ELECT G UIDE AND C HARGE C ODE S ELECTOR
-50-40-30
-20-1001020304050
E MERSON C LIMATE T ECHNOLOGIES
2
A
A
C
E
B
2
H C 30 IN 3/8 x 1/2ODF ANG
V alve Superheat Adjustment Internal Equalizer Bleed Hole Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series Check (optional)Nominal Rating Code Code T ube
Connection T ype uration Economy, A = Adjustable V alve E=External in Tons F = R12
Length Sizes SAE =Hermetic (optional)Omit for H = R22 C = medium temp I O flare S/T =Design
N = Non-Adjustable
Reverse (Omit for no bleed See nominal M = R134a CA = heat pump 30 IN (std)1/4 3/8ODF =straight-Flow Internal)
hole
capacity N = R407C W(MOP)=press. limiting other 3/8 1/2solder thru Bypass table P = R507Z = low temp lengths are 1/2 5/8Chatleff Application
below
R = R502AA = wide range available 5/8 7/8(optional)ANG =
S = R404A Aeroquip 90°Z = R410A (optional)angle
Hermetic construction eliminates external leakage Compact size allows installation in limited spaces
Mass spectrometer tested to ensure less than 0.10 oz/year external leakage rate
Stainless steel power element eliminates corrosion and prevents valve failure
F EATURES
S PECIFICATIONS
Maximum working pressure:700 psig UL Recognized:SA 5312
“A” Series Thermo Expansion Valves are used for heat pump,air conditioning, food service and commercial applications.“A” Series valves provide stable and accurate control over a wide range of operating conditions.
N OMENCLATURE EXAMPLE : AACEB 2 HC 30 IN 3/8 X 1/2 ODF ANG
HAA wide range charge allows two valves ( 2 1/2 and 5 ton, R-22) to cover all capacities from 1 to 5 tons on most residential systems
New ZW195 charge available for R-410A systems Available adjustable or non-adjustable superheat for application flexibility
SAE or ODF connections standard – chatleff or aeroquip are available
Available external or internal equalizer to satisfy the broadest possible range of applications
Available internal check valve allows reverse flow heat pump applications, eliminating the need for external piping and external check valve, thus reducing installation costs (ANC Series)
Bleed type pressure equalization available to accommodate PSC type compressors
Pressure limiting charges (MOP) available – consult factory
O PTIONS
Extended Capacity Tables begin on page 36.Ordering Information begins on page 3.
R12
R134a
R22
R410A
R502
R507/R404A
R407C
–
1/81/5––1/81/51/81/41/41/41/81/41/41/41/21/21/21/41/21/21/23/4111/23/41111?1?111?–1?22–1?21?22?31?22?22?3422?3?2?3452?2?43
4
5
–
3
3?
5?
AA/AN S ERIES – N OMINAL C APACITY T ABLE IN T ONS
Standard Product Offering* Product Code Number S/T = Straight Through
E MERSON C LIMATE T ECHNOLOGIES3
E MERSON C LIMATE T ECHNOLOGIES
4
V A L LV V E C A P A C I T Y
P C
N* C HA R G E GE
C A P
S E R I E S
T O N S
C O N N E C T I O N S
C F H C A H W 100
T U B E
R -12/R -134-134a
a M E D . T E M P .R -22 H E A T P U M P
R-22 MOP
23/8 X 1/2 ODF ANG 00750630 IN.2 1/2
3/8 X 1/2 ODF ANG
007507
30 IN.
U NIVERSAL R EPLACEMENT
HAA AND ZW195 W IDE R ANGE C HARGE FOR HVAC A PPLICATIONS
The AACE wide range valve allows several TXV to replace the majority of residential air conditioning and heat pump applications.
Special high stability charges designed for HVAC applications and used by leading original equipment manufacturers. These wide range charges provide greater superheat stability,allowing in most cases two valves to cover a wide range of capacities from 1 to 5 tons.
Offers customers the benefit of inventory reduction by replacing several valves with two valves, while continuing to meet system performance needs.
With the addition of an integral check valve, four expansion valves can meet the majority of residential HVAC, light
commercial, and heat pump applications as shown in Table 1.
T ABLE 1
SUPERHEAT SCREW REPLACEMENT KIT 20297
AACE D IMENSIONAL D ATA
O RDERING I NFORMATION FOR A-S ERIES V ALVES
ANEB
E MERSON C LIMATE T ECHNOLOGIES
5
External superheat adjustment Replaceable inlet strainer SAE connections only
Wrench flats on inlet and outlet for easy installation Stainless steel power element for maximum corrosion resistance
F
EATURES
The AFA series Thermo ? Expansion Valve is designed for air conditioning and commercial refrigeration applications requiring angle configuration SAE connections. The AFA is ideal for those applications requiring compact size com-bined with stable and accurate control over wide load and evaporator temperature ranges.
For Ordering Information, see page 6.
Maximum working pressure:700 psig
UL Recognized:
SA 5312S PECIFICATIONS
Available external or internal equalizer to satisfy the broadest possible range of applications
O PTIONS
AF
A
E
1/2
H
C
5 FT
3/8 x 1/2
SAE
ANG
V alve
Superheat Adjustment Equalizer Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series Nominal Rating Code Code T ube Connection T ype uration Economy, A = Adjustable
E=External in Tons F = R12Length Sizes Hermetic H = R22 C = medium temp SAE =ANG =Design
(Omit for See nominal M = R134a CA = heat pump 30 IN 1/4 x 3/8flare
90°Internal)
capacity N = R407C W(MOP)=press. limiting
and 3/8 x 1/2
angle
table P = R507Z = low temp 5 FT (below)
R = R502AA = wide range
are standard
S = R404A Z = R410A
N OMENCLATURE EXAMPLE : AFAE 1/2 HC 5 FT 3/8 X 1/2 SAE ANG R12
R134a
R22
R410A
R502
R507/R404A
R407C
–1/81/5––1/81/51/81/41/41/41/81/41/41/41/21/21/21/41/21/21/23/4111/23/41111?1?111?–1?22–1?21?22?31?22?22?3422?3?–3–5–2?43
4
5
–
3
3?
5?
AFA S ERIES – N OMINAL C APACITY T ABLE IN T ONS
AFA(E) CONNECTIONS
TOLERANCE
± 5/32 (.16)± 1/32 (.03)
± 3/64 (.05)
I N L E T O U T L E T A B
C 3/81-41/641/41/21-49/641-3/32
1-23/64elbow 5/81-63/643/8 – 1/21-47/643/81-41/643/81/21-41/641-5/16
1-23/64elbow
5/81-63/643/8 – 1/2
1-47/64
AFA(E) D IMENSIONAL D ATA
Remote Bulb Tubing Length 30” or 5’ Standard
DIMENSIONS SHOWN ARE IN
INCHES:
FRACTIONS (DECIMAL)
O RDERING I NFORMATION FOR AFA S ERIES V ALVES
Standard Product Offering* Product Code Number
6
E MERSON C LIMATE T ECHNOLOGIES
E MERSON C LIMATE T ECHNOLOGIES
7
O PTIONS
ODF or SAE connections
Straight-through or angle flow configurations Removable inlet strainer available (ODF only)
Internal or external equalizer
SAE
1/4 thru 5-1/2 tons
R 22
ODF
LENGTH
D IMENSIONAL D ATA
DIA.
O D F
w/optional strainer at inlet
LENGTH
DIA.
Remote Bulb Tubing Length 5’ Standard
Maximum working pressure: 450 psig Operating Temperature: -40°F to 50°F
Use with R-22, R-134a, R-404A, R-507, R-12, R-502S PECIFICATIONS
O D F
Top V iew
Showing External Equalizer Location
HFK
E
S
C
2
H
C
5 FT
3/8 x 1/2ODF S/T
V alve Equalizer Connection R emovable Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series
T ype Inlet Nominal Rating Code Code
T ube Connection T ype uration E=External S=Solder Strainer in Tons F = R12Length
Sizes (optional)H = R22 C = medium temp See Body SAE =S/T =(Omit for (Omit for See nominal M = R134a CA = heat pump 5 FT (std)Table on flare straight-Internal)
SAE C=Inlet capacity N = R407C W(MOP)=press. limiting other
page 23thru
Flare)
Strainer table
P = R507Z = low temp lengths are
ODF =(ODF only)
R = R502available
solder ANG =
S = R404A
90°angle
N OMENCLATURE EXAMPLE : HFKESC 2 HC 5 FT 3/8 X 1/2 ODF S/T
F EATURES
The HFK features interchangeable bodies, cages, and power elements providing maximum flexibility for ? to 5? ton applications (nom. R-22). The HFK is offered several ways:
Pre-packaged service kits – Include a mix of bodies and power elements with a complete set of cages to serve the most applications with a minimum of parts. Individual components - Bodies, cages, & power elements may be ordered separately and can be used to build personalized service kits or replenish pre-packaged kits.
Finished valves – Assembled valves ready for immediate installation.
All HFK valves use a balanced port cage design that compensates for changes in operating pressures due to varying ambients, gas defrost, heat reclaim, or widely varying evaporator loads.
The HFK offers the following additional features:
Bi-Flow capability
Stainless steel power element Adjustable superheat Solid copper connections
DIMENSIONS SHOWN ARE IN
INCHES:
FRACTIONS (DECIMAL)
Refrigerant Charge
L e n g t h D i a.C, Z 3-1/21/2CA
2-5/16
3/4
Remote Bulb Dimensions
HFKESC
ODF C ONNECTIONS
R EPLACEMENT S CREEN K IT KT20264
NOTE :HFK cages are not interchangeable with HF valve
bodies. Power elements can be interchanged.
HFK B ALANCED P ORT TEV
Cage Capacity T
Cage Capacity Table (Nominal) Cage
Code R-12R-22
01/8?
1??
2?
311?
41?
51?2?
P ower Element T
ower Element Table
able1
PCN*Description
Description System Refrigerant(s)
System Refrigerant(s) Application X26300-FW15-1R-12/R-134a L ow T emp MOP
X26300-FW35-1R-12/R-134a L ow T emp MOP
X26300-FW55-1R-12/R-134a L ow T emp MOP
X26300-MC-1R-134a Medium T
X26300-HW100-1R-22/R-407C AC MOP
X26300-HCA-1R-22/R-407C Heat Pump
HFK S ELECTION P ROCESS
Step 1: Body Selection
E MERSON C LIMATE T ECHNOLOGIES 8
HFK B ALANCED P ORT TEV (PCN 065135)
E MERSON C LIMATE T ECHNOLOGIES
10F EATURES
HFESC
ODF C ONNECTIONS
O PTIONS
Large, removable power element
Balanced port construction compensates
for changes in operating pressures due to varying ambients, gas defrost, heat reclaim, or widely varying evaporator loads
Two body sizes provide capacities from 1/4 to 20 tons Bi-Flow capability up to 5-1/2 tons R22 allows one valve to control the superheat in both cooling and heating modes for package unit heat pump applications Wrench flats on inlets and outlets (SAE only) for easy installation
Stainless steel power element for maximum corrosion resistance
Bleed type pressure equalization available to accomodate P SC t ype c ompressors ODF or SAE connections Removable strainer
Adjustable or non-adjustable superheat
SAE
LENGTH
DIA.
1/4 thru 5-1/2 tons R22
ODF
LENGTH
D IMENSIONAL D ATA
DIA.
ODF
w/optional strainer at inlet
LENGTH
DIA.
R EMOTE B ULB T UBING L ENGTH 5’ S TANDARD
Maximum W orking P ressure: 450 p sig Operating Temperature: -40°F to 50°F 5' capillary tube length (standard)
Use with R-22, R134a, R-404A, R-507, R-12, R-502
S PECIFICATIONS
Refrigerant Charge
L e n g t h D i a.C, Z 3-1/21/2CA
2-5/16
3/4
Remote Bulb Dimensions
ODF Top V iew
Showing External Equalizer Location
R EPLACEMENT S CREEN K IT
KT20264
HF
N E S C
B
2
H C 5 FT 3/8 x 1/2ODF S/T
V alve Superheat Equalizer Connection R emovable Bleed Hole Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series
Adjustment T ype
Inlet (optional)Nominal Rating Code Code T ube
Connection T ype uration
E=External S=Solder
Strainer in Tons F = R12
Length Sizes N = Non-(optional)Omit for H = R22 C = medium temp I O SAE =S/T =Adjustable (Omit for (Omit for
no bleed See nominal M = R134a CA = heat pump 5 FT (std)1/4 3/8flare straight-Internal)SAE
C=Inlet hole
capacity *P = R507W(MOP)=press. limiting other 3/8 1/2thru Omit for Flare)Strainer table *R = R502Z = low temp lengths are 1/2 5/8ODF =Adjustable (ODF only)
(on page 17)
*S = R404A available
5/8 7/8solder ANG =
90°angle
N OMENCLATURE EXAMPLE : HFNESCB 2 HC 5 FT 3/8 X 1/2 ODF S/T
DIMENSIONS SHOWN ARE IN INCHES:
FRACTIONS (DECIMAL)
* P , R and S charges are interchangeable
Extended Capacity Tables begin on page 43.Ordering Information begins on page 12.
NOTE :If the HF body is stamped HFK, then the valve has
replaceable components.
E MERSON C LIMATE T ECHNOLOGIES 11
HF D IMENSIONAL D IAGRAM
External Equalizer
E
F
3/16 ODF .192 ± .002.31 ± .031/4 ODF
.254 ± .002
.33 ± .03
R EPLACEMENT P OWER A SSEMBLIES
R12 P OWER POWER A SSEMBLY
R22 P OWER POWER A SSEMBLY
R502 P OWER POWER A SSEMBLY
X26300-FC-1
X26300-HC-1
X26300-RC-1
X26300-FZ-1X26300-HZ-1X26300-RZ-1X26300-FW15-1X26300-HW35-1X26300-RW45-1X26300-FW35-1
X26300-HW65-1
X26300-RW65-1
INLET/OUTLET C ONNECTIONS SIZE O DF C ± .002
D ± .03
1/2.504.375/8.629.507/8.879.761-1/8 1.129.901-3/8
1.379
.97
ODF Top V iew Showing External Equalizer
Location
Refrigerant Tube Length
Dia.
Charge Length dimension
dimension
CA
10 FT.2-5/163/45 FT.10 FT.
C, Z – WMOP
ODF
8, 10, 15 & 20 ton R-22 V alve
3-1/2
1/2
LENGTH
DIA.
HF B ALANCED P ORT TEV
Remote Bulb Tubing Length 5’ Standard
R12
R134a
R22
R502
R507/R404A
1/81/41/41/81/81/41/21/21/41/41/23/411/21/2111?11–1?2––1?1?2?1?1?22?3223?45?3?3?5685567?107791115101012
14
20
13
13
HF S ERIES – N OMINAL C APACITY T ABLE IN T ONS
T SAE l C
O RDERING I NFORMATION FOR HF S ERIES V ALVES
12
E MERSON C LIMATE T ECHNOLOGIES
O RDERING I NFORMATION FOR HF S ERIES V ALVES(CONT’D)
MERSON LIMATE ECHNOLOGIES
O RDERING I NFORMATION FOR HF S ERIES V ALVES(CONT’D)
(CONT’D)
14
E MERSON C LIMATE T ECHNOLOGIES
O RDERING I NFORMATION FOR HF S ERIES V ALVES(CONT’D)
Standard Product Offering* Product Code Number
E MERSON C LIMATE T ECHNOLOGIES15
E MERSON C LIMATE T ECHNOLOGIES
16TRAE Nominal
Sizes (ODF)Inlet Outlet V alve T alve Type ype
Inlet (B)Outlet (E)A C D F 5/87/8 1.570.50 2.090.755/81-1/8 1.570.50 2.210.91TRAE+7/87/8 2.090.75 2.09
0.7510-40
7/81-1/8 2.090.75 2.210.91TONS
7/81-3/8 2.090.75 2.390.971-1/81-1/8 2.210.91 2.210.971-1/81-3/8 2.210.91 2.390.971-1/8
1-3/8
2.21
0.91
2.39
0.97
The TRAE Plus thermostatic expansion valve (TXV) is a large capacity series designed for refrigeration, air condi-tioning, heat pump, and chiller applications. The new series introduces a new replaceable stainless steel power element, a fully interchangeable cage assembly and a square body.
This valve type features double balanced port design, which provides stable and accurate control over wide loads and evaporator temperature ranges. Furthermore, a permanent inlet strainer and external adjustment are standard on every valve.
F EATURES
Suitable for Bi-Flow applications.
Removable power element and cage assembly for full serviceability.
Stainless steel power element for enhanced corrosion resistance
Double balanced port design improves operation and stability under low load conditions.
Square body with straight-thru connections. Solid copper connections. External superheat adjustment.
Large diaphragm provides superior stability HCA charge designed especially for R22 air conditioning applications.
S PECIFICATIONS
Ratings from 10 to 40 tons.
Maximum working pressure: 450 psig Torque Power Assembly: 375 - 425 in. lb. Torque Cage: 60 in. lb.
IMENSIONAL
ATA (INCHES )
TRA
E
+
30
H
C
10 FT
7/8 x 11/8
ODF
S/T
V alve Equalizer R eplaceable Capacity R efrigerant Char Charge ge Capillary Inlet x Outlet Connection Config-Series
Components Nominal Rating Code Code T ube Connection T ype uration E=External in Tons F = R12Length Sizes 1/4” SAE
Cage and H = R22 C = medium temp I O ODF = solder S/T =Power See nominal M = R134a CA = heat pump 10 FT 5/8 7/8(Only)
Straight-Assembly
capacity N = R407C W(MOP)=press. limiting
(standard)7/8 11/8thru table P = R507Z = low temp
11/8 13/8
(Only)
(below)
R = R502Other S = R404A
lengths are available
N OMENCLATURE EXAMPLE : TRAE+ 30 HC 10 FT 7/8 X 11
/8
ODF S/T
O PTIONS
Cages KT20289 thru KT20293
Remote Bulb Tubing Length 10’ standard,other lengths are available
Replaceable Power Assembly X-28458
R12
R134a
R22
R502
R507/R404A
R407C
7?910881010131512121512142014142018223020203025
30
40
30
30
40
TRAE+ S ERIES – N OMINAL C APACITY T ABLE IN T ONS
TRAE+ and TRAE Series Extended Capacity Tables begin on page 43 in
Tons. For Ordering Information, see page 18.