VISTA120/250常见故障(总线/通讯/子系统)及处理

①常见问题

Q1: 主机加电后6160(6139)键盘无反应

A: (1)可能是新主机未编入适当地址码,首先同时按下[1][3],输入地址码为01,按※退出。一般就可以正常使用。

(2)看主机的1、2端子是否有交流16.5伏电压?6、7端子是否有12伏直流电压?如果检查16.5伏电压不正常可能是220伏交流电源或变压器损坏,检查更换使其供电正常。如果主机上没有直流12伏电压输出或电压不正常送修处理

(3)检查主机到键盘的接线是否正确?如果错误请将接线按接线图正确连接

主机接线端子6 7 8 9

对应键盘线颜色红黑绿黄

如果还没有显示请找到直接供货商送修处理。

Q2: Vista120的主机,用安装员密码为什么不能撤防?

A:使用快速布防时,安装员码是不能撤防的,但可以用主用户码撤防,我们建议客户使用主码或操作码进行布防或撤防操作。

Q3: Vista 120的安装员密码忘记了,怎么办?

A:将主机断电,重新上电,在30秒之内同时按*和#,进入编程,按#00进行查看,按*00进行更改安装员密码。就可以了。

Q4: 6160(6139)键盘显示CHECK 97

A: 一般用万用表测量电压正常为10-11伏,如果只有几伏电压

或没有电压,则判断总线有短路故障或负载太大,检查总线各节点和分支使其恢复正常。

Q5: 6160(6139)键盘显示CHECK XXX

A: (1)检查防区内是否有人在活动?如果有人,请他退出或默认该防区为正常。

(2)如果无人则检查该防区探测器工作是否正常?如果不正常请首先检查探测器电源。其次检查探测器信号线是否断路。

(3)检查该防区地址码模块是否正常?如果不正常首先检查地址码模块与总线连接的接线是否正确(正、负是否接错)?其次检查地址码模块是否损坏?必要时更换一个试试。

(4)可能防区编程没有编好,请将原来的防区重新删掉,然后再重新学习序列号试试。

Q6: Vista 120主机一直处于System Reset的位置,怎么操作也不行,为什么?

A:可能是主机有问题了,请将主机寄往经销商维修。

Q7: 6160(6139)键盘显示SYSTEM LOBA T

A: (1).是否未接后备电池?如果未接则需要连接电池或默认该情况为正常。

(2)如果已连接要检查后备电池是否电压不足?(从主机上拔下来用万用表测量),电压不足的原因首先可能充电时间不足,请继续充电。其次电池老化,需要更换。

Q8: 6160(6139)键盘显示SYSTEM LOBA T,不能布防。

A: 主机菜单编程05项出厂值为“0”,低电压不能布防。如果确实需要请改为“1”,低电压也可以布防。但此项改动需要慎重。

Q9: 6160(6139)键盘显示OPEN CKT,按任何键不起作用,断电重新启动无效。

A: (1)键盘接线错误,对照手册检查接线,更正错误。

(2)检查主机板是否有短路情况,如有请排除。

Q10: Vista 120主机是否可以联动灯光,该怎样连接?4293SN与4100SM是做什么用的?

A: Vista 120主机通过继电器输出,是可以联动灯光的。继电器输出一个开关量来控制高功率的继电器来控制大电流的设备。4293SN是一个单防区地址码扩展模块,用来接探测器的,4100SM是用来连接电脑与主机的,探测器报警,主机将报警信号传送到电脑上。

Q11: Vista 120主机接了4208SN模块,怎么编程,它在报警时,键盘上显示“Check XXX………”

A: 按照说明书来做,先进入编程状态,再按*93进入防区编程,然后找到对应的防区号编程,先确定防区类型,然后在输入类型输入06,最后就是自动学习序列号(也可以手动输入序列号)。以上都做完了就可以了。如果键盘上显示“Check XXX”就是防区没有找到或设好,请重新编程设置。如果显示“Fault XXX”则是防区错误,请检查防区。

您出现的这种情况,也有可能是您的4208SN模块的拨码开关没有拨对。可能您是把第8位开关拨到有效位置了,请将防拆设为无效

就可以了,或者将4208SN的磁铁装上并合上盖子。还要注意总线电压是否正常?北京一个用户就是4208SN元器件击穿造成总线电压只有6.7伏。

Q12: Vista120主机4193SN如何接线,如何编程?

A: 4193SN是一个两防区模块首先要将模块接好,有一端出来的是红色与黑色的线是用来接总线的。另一端出来四根线,白、黄、绿、黑。白或黄与黑色组成第1个防区,白色与黑色组成的防区是需要接EOL电阻的,而黄色与黑色则不用,白与黄只能任选其一做为1防区。绿与黑组成2防区,是常闭回路。接好之后,进行软件编程,将防区的输入类型为06,LOOP设为1(防区1为1)和2(防区2为2)然后直到读取序列号的位置,将需要编程的防区断开后再复位。主机就会自动将序列号读好。这样就会把防区编程好了。

Q13: Vista120主机为什么通过4100SM与电脑通讯不上?

A: 请检查电脑的串口是否正常,然后检查主机的编程是否已经编程,1*70-1*73这几项。然后使用串口检测软件,检查4100SM是否有数据发出?如果没有的话,请将4100SM返修。

②主机一般操作和用户密码问题

Q1: 请问一下,Vista 120主机,我怎么进不去编程呀。

A: 先把主机断电,然后通电,同时按住*与#键,在约5秒,就可以进入编程了,按*93进入防区编程。

Q2: 请问一下,Vista120的主机,我的密码怎么改?还有就是主机的时间如何更改?

A:修改安装员密码:在进入编程状态下,输入*00 和新密码就可以了。修改用户码:按安装员码+8+用户号(xxx)+新密码+新密码。这样就可以设置密码了。更改主机的时间是按密码+#+63 就可以根据提示修改了。

Q3: Vista120的键盘上显示Fault ***防区。

A:这是你的某个防区有问题,或者是防区没有复位造成的。还有就是这个防区的线尾电阻的阻值是否在2K 左右。请检查探测器及其到主机之间的连线是否正常?

Q4: 我的主机出现了All secure * *,按安装员码+1没有反应?

A: 可能是您误用其它密码进行布防,安装员码不能撤防了,可以使用主码(1234)进行撤防。建议使用1234主码进行布撤防操作。

Q5: Vista120的键盘上显示Key tamper。

A: 出现这个提示是您多次在键盘输入了无效数字而造成的,需要断电重启就可以恢复了,或者等上20分钟之后自动恢复。

Q6: Vista 120主机在上电时就进入了布防状态,但是无法撤防?

A:请使用用户密码1234+1进行撤防,如果这个办法不行的话,就在上电时,同时按住*与#键进入编程,找到编程项*28后将数值改为0就可以了。然后再增加能够撤防的用户密码。以后记住别用安装员码进行布/撤防。这些事情都做完后记得将编程项*28数值改回为1。

Q7: 请问一下,我的Vista120主机的旁路为什么不行呀。

A: 是否您操作错误了,检查一下是密码+6+防区号。还要检查

该防区是否编程为不许旁路,另外火警防区也不能旁路。

Q8: 请问Vista 120主机配了一个IC 芯片,这是做什么用的?

A: 这是一个不同版本的IC,在中国是不用的。

Q9: 请问一下,Vista120主机为什么老是每隔一段时间就响一下,可不可以消除呀,还有就是无法跳转子系统。

A: 可能是你设置成了响铃模式,按密码+9+#,可以消除了。跳转子系统可能是没有在2*00和2*18里面编程,进入编程,按照说明书更改。

Q10: 请问一下,Vista120主机可不可以将任何一个防区做为布防或撤防来使用?

A: 可以的,但不是任何一个防区。一般只能使用硬防区07,在数据编程项*15选定子系统(1-8)。设定后07防区连接4146布撤防锁,就可以用做布撤防。利用4193SN地址码模块也可以支持总线防区实现布撤防。

Q11: Vista 120接单防区与双防区模块地址码不会有重复性吧。

A: 不会有重复性的,因为4193与4293都是读序列号的,不会有相同的序列号的模块。

Q12: 6160的键盘可以外接电源吗?

A: 这是可以的,但必须要与主机用一个公共地。

Q13: Vista120接的设备地址最多接32个设备,是不是继电器也可以接32个模块?

A: 设备地址是01-30。继电器一共只可以接8个模块,继电器的

地址也在01-30的地址之间。

Q14: Vista120主机为什么不能删除密码呀。

A: Vista120的主机删除密码是先输入主码+8+用户编号+主码(注意是具有删除权限的)这样的就可以把这个用户编号的密码删掉了。

Q15: 我使用了Vista120,可不可以增加无线的防区。

A: 这是可以的。Vista120可以通过总线和无线将防区数扩充到128防区,如果增加无线防区还要增加无线接收机。

Q16: Vista120接了6个键盘,请问能不能走一千多米?

A: Vista120的键盘直线混合总线最远是600多米,太远的话是不行的,您可以试试,加粗线径,或者再增加一个主机。

Q17: Vista120主机出现了打印机掉线?怎么处理?

A: 这是您的电脑与主机连接失败了,请检查电脑的串口是不是有问题,连接串口线是不是断线了。并windows通讯软件检查4100SM 是不是有信号输出。

Q18: Vista250主机的时间表编程,但是内部的时钟总是很慢的。为什么?

A: 如果每天差的不多可以在数据编程项1*50进行增加时间调整。

Q19: 我的Vista120主机接了四十多个探测器,同时触发时,只能接到三个报警信号?

A: 您可以在数据编程*84项位置设为00就可以了,它默认是

03也就是只有3条信息同时往中心报告。改为00就是不限制了。

Q20: Vista 120 主机,探测器只要检测到有人,键盘就会响。我想取消这个声音,怎么办?

A: 可能是设置了响铃模式。使用密码+“9”,消除一下试试。

③主机总线问题

Q1: 120主机的,接了三条总线,现在主机老报错。不知道是为什么?

A: 您的总线距离分别1000米与300米/200米,总线加起来是1500米了,而且你是使用1平方的线材,只能达到1200米,您可以加一个4297总线延伸模块。

Q2: 请问Vista250的主机是采用什么总线的。它的传输距离最远是多远?

A:250主机是采用V-Plex总线,它的传输距离是1200米(当然线径至少是1平方的非屏蔽线才行。)

Q3: Vista120的总线是采用什么协议的,是不是485信号,能传多远?

A:Vista120主机的总线协议是采用V-plex格式是安定宝设定的,不是一般的485协议,它的传输距离是1200米。

④主机通讯问题

Q1: Vista120主机的电话线怎么接?

A: 端子28、29(T/R)是用来接电话线的,端子26、27(T1/R1)是用来接电话机的。

Q2: 请问一下,Vista120主机的电话编程怎么编?

A:Vista120主机的电话编程,需要在数据编程项*30设置为音频拔号方式、*32输入一个帐号、*33输入电话号码(也就是接警中心的电话号码)*45选择与接警中心相匹配的协议。以上设置了就可以拔号了。

Q3: Vista120不拔号?编程设置肯定是没有问题的。

A:您可以使用另一台主机,进行同样的编程,看能不能拔号,具体设置是在(*30 设置音频拔号,*32是设置帐号的,*33设置接收机的电话号码的。)如果只是往手机上拔的话,只需要设置这些就可以了。

Q4: 我的Vista120主机,在主机进行布撤防时,这个布撤防报告往中心上报时,很慢,但是报警信息却是很快的。

A: 可能是您的主机设置了延时防区,所以在主机布防时,会有一定的延时。另外,还有一个原因是报警级别高于其他报告。

Q5: Vista120主机为什么不上传布撤防报告吗?

A: 可能您没有设置好布撤防的报告码。应该在报告码的编程里进行设置(注意2位报告码都不为0)。还要在添加用户码时选择发送布撤防报告。

⑤子系统问题

Q1: 请问一下,我的Vista120主机使用了多个密码键盘分别控制子系统,但是还是一布防就全都布防了。

A: 这是你的主机没有把键盘划分到子系统,使它的权限只能单

系统布防。具体在#93菜单编程里的设备编程中将键盘划分到子系统。

Q2: 主机Vista120要分子系统的话,在2*00这里设置了子系统数量,在哪里设置跳转功能,我在2*18这里,只能设置1子系统。为什么。

A:在2*18这里是需要分子系统设定的,在其中一个子系统设好后,然后退出编程。再重新进入编程对其他子系统进行设置。依次循环操作就可以了。

Q3: Vista 120主机,分3个子系统。我加了两个固定字符键盘后,为什么在固定字符这边一布防,就整体布防了,一撤防,就整体撤防了。

A:这是由于你的密码没有分配给子系统,还有就是你的键盘也没有分配给子系统。请进入编程,在2*00和2*18两个指令中把子系统与子系统跳转设置好,然后进入#93菜单,在设备编程里,把键盘分配到各个子系统。最后增添密码,当然密码控制哪个子系统也得分好,具体操作,请查看说明书。

Q4: 请问一下,我要将防区划分为9个子系统,怎么办呀。我的键盘接了5个,是正常的,但是接第6个的时,就整个都不行了。

A: Vista250主机只支持8个子系统,你要把防区分为8个子系统就可以了,你的键盘连接时,可能是连接错误或者是键盘的地址码冲突了。请检查键盘的连接线与地址码。

Q5: Vista120主机,分了4个子系统,只使用了一个主控制键盘,但是只有子系统1的防区报警时,键盘才会响,其它子系统却不会响,

为什么?

A: 这是你的键盘在子系统1,所以只有1子系统的防区报警才会响,只有当你跳转到其它子系统时,其它对应的防区报警,这时键盘才响。如果键盘在一定的时间内未进行操作时,键盘会从其它子系统自动跳转到1子系统的,只有将键盘编入子系统9(虚拟主控键盘),键盘上显示所有子系统的状态。这时,所有子系统的任何一个防区报警,键盘都会响了。

Q6: Vista120要分8个子系统的话,是不是一定要8个键盘来控制?还有时间也无法改变?

A:要分多个子系统,如果想方便的话,可以使用多个键盘控制,也可以使用一个键盘跳转来控制其他子系统,但是这种方法比较麻烦。改变时间的命令是安装员密码+#63。

Q7: Vista250主机,分了四个子系统,如何对每个子系统设置一个密码。

A: 如果您想要每个子系统设置一个密码,就应该先进入密码编程设置,然后再添加密码,将这个密码设为在某个子系统下操作,这个密码就只能在这个子系统下操作了。

Q8: Vista120分了五个子系统,我安装在保安室的键盘想对整个系统布撤防怎么办?

A: 您好,要想对所有的子系统进行布防的话,你可以使用密码权限来设定了.让这个密码拥用整个系统布撤防的权限,就可以了。

Q9: Vista120主机连接IPAlarm软件时,电脑只能控制1子系统,

但是2子系统与3个子系统都不能控制。这是为什么?

A: 如果要分多个子系统的话,需注意2*00编程里要设置子系统数量,还要在软件这边增加多个用户号,一个用户控制一个子系统,还有就是在主机编程这里的设备编程位置,给予每个子系统一个虚拟的键盘地址,从16-23开始与8个子系统相对应。

Q10: 我使用的是Vista 120主机,可不可将同一类型的探测器分为一个子系统?

A: 是可以分为一个子系统的,当然你的单个防区上也必须安装成同一类型的探测器才行呀。这些防区按数量分为最多8个子系统。可以对单个子系统进行布防。也可以整体布防。

Q11: Vista120主机怎么对键盘编入虚拟子系统的?

A: 只需要在#93编程里面的(DEVICE PROG)设备编程中把键盘归纳为第9个子系统就可以了。

Q12: Vista120主机接上两个键盘,分子系统时如何划分?

A: 首先把键盘的地址码设置好,但不要设同样的地址,然后在设备编程项将这个两个地址码分别编为不同的子系统,就可以了。

⑥与其它附件配合问题

Q1: Vista120 经常出现红外对射防区误报?

A: 这是你的前端探测器的问题,由于探测器不是我们的产品,我就无法解释。如果你觉得是主机的问题,请将主机的防区断开,直接接上电阻,看防区是否也经常误报。如这样也出现误报的话,请发回我处返修。

Q2: Vista120的扩展模块4208上接的紧急按钮经常出现误报,为什么?

A:请排除是不是人为造成的,再检查紧急按钮是不是好的,编程是不是有错。如果以上都不是的话,请将误报的防区从主机上断开,直接接上电阻(10K),看主机是否也误报。如果还是的话,就换一个试试。

Q3: Vista 120主机接了6160的键盘,我想把一部分作24小时都要报警,一部分只有在布防的情况下才报警。我还有一个6148的键盘,可不可以不要。

A:这个很容易就可以做到了,你只要将你想作为24小时都要监控的防区设为24小时防区(编程时,输入防区类型:07)把想作为布防时才报警的防区设为内部防区或周边防区也可以,(编程时,输入防区类型03或04。对于防区类型的选择,请看说明书来选择你想要的防区类型。6148的键盘你可接,也可以不接,接了的话就是说明你多了一个操作点而已。

Q4: 请问Vista250的可以带多少个继电器?

A: Vista250主机是可以带96个继电器,由8个4204模块和64个4101SN总线继电器组成。需要注意的是对于报警来说,是使用防区列表方式的,即一个继电器可以有多个防区联动。

Q5: Vista120,接了一个4146的布撤防开关锁,请问有哪些编程才能使用这个开关锁。

A: 您只需要将数据编程项*15与*40设置一下就可以用,那个

LED的驱动电压要在1*46里设定为布撤防触发器。

Q6: Vista120主机,有30个防区,使用4293模块,要怎么配?可不可以单独防区布防?

A:Vista 120如果主机的基本防区不用的话,就要配30个4293模块,主机的基本防区有9个防区。不可以每个防区单独布防,不过可以将30个防区分为8个子系统,子系统可以单独布防。

Q7: 请问一下Vista120主机,我的4204继电器模块能不能实行防区对应的联动呀。该怎样实行呀。

A: 用4204继电器模块的话,可以实行15个防区列表一一对应,这个在继电器编程里就可以设置了。

Q8: 请问Vista120怎样实行联动。

A: 如果矩阵也是Honeywell的话,是可以实行软件联动的,如果不是,只能实行硬件联动的,也就是通过继电器来实行了。

Q9: 我在总线接了一个紧急按钮,使用的是4193模块。按紧急按钮时没有反应。

A: 您好,接总线的时候,是需要进行防区编程的。先进入编程,然后按#93 进入防区编程,在输入设备类型时,输入06选择序列号类型,直到要你学习序列号时按1确认,出现一个Input s/n A×××然后,将你要编的防区触发一次,这样模块的序列号就自动学进去了,再一次触发同一防区,进行确认。这样这个防区就编完了。

Q10: 我的Vista120如何实现自动布撤防?

A: 您好,首先在密码+#+80的时间编程,设时间列表和布撤

防列表。然后在2*05 自动布防延时时间

2*06 自动布防警告时间

2*07 自动撤防延时时间

2*08 强制布防(自动旁路)

2*10 限制在撤防时间窗内撤防最后就可以进行自动布撤防了。

Q11: 我有个客户出现这样一个现象。Vista120的主机,在不接4297模块的时候,只是出现Check ×××但是接上4297模块后,出现了Check 997。

A: 出现Check 997 就是表示主机的总线输出电流过大。可能是您的设备接的太多了,您可以将4297移至主机旁边,只接4297,其它探测器都不接,检查主机是否还出现Check 997,如还有的话,就表明4297有短路的问题。否则,就是您在4297的前端接了太多的模块,造成总电流超过了128mA。

Q12: 我的主机Vista120接十五个4204,但是说明书上说有一些地址码不可以用?那怎么办?还有就是我在编程进无法修改。

A: 4204只能接8个模块,超过的模块地址是不会被识别到的。无法编程:可能是您先按了#之后再按数据项的,您需要先按*才可以编程,按#是查看数据项的参数。

Q13: 我的主机Vista120已经在时间窗,把时间表与布撤防表都编好了,但是还不能自动布防。

A: 您还得需要在2*05-2*11这些数据项里进行编程,就可以自动布防了。

Q14: Vista120主机直接接了一个打印机,只有撤防报告出来,但是布防却没有出来?

A: 请您检查一下,报告码编程里面的系统组里的布防报告码是否已经打开?

Q15: Vista120主机的4193可不可以与探测器共电压呀。

A: 4193是总线模块,不需要外接电源的。总线回路已经提供给4193的电压。

Q16: 我的周界可能有10公里左右,用Vista120怎样才能做到?

A: Vista120是达不到这个要求的。最好使用多个主机,每个主机加IP2000通过IP网络来实现。

Q17: 我有96个防区,20个继电器。如何实现联动?

A: Vista120只能支持15个防区列表,所以您可以使用15个继电器,将所有防区分配到15个列表里面,实现联动。

Q18: Vista120接4204模块,是不是只能接8个模块?如果接了很多的继电器,怎么办?

A: 接4204继电器模块最多只能接8个模块,其他的只能接4101总线继电器模块了。

Q19: Vista120与4208SN连接后,出现了Check ***。

A: 请检查这个防区的防区模块是否连接正确,序列号是否正确读取,并检查4208模块的第8位开关是否至于ON的位置。

Q20: Vista120主机是多少防区的。怎样与4193模块连接。

A: Vista120主机是支持128个防区,4193是总线防区模块,通

过总线连接的。

Q21: Vista120连接了4193后,出现了报警延时?

A: 请将4193接到主机的附近进行检测,并检查防区的类型是否使用了延时防区,在主机通电后,过一分钟之后进行布防(不要在主机刚通电就布防,因为主机还没有通过自检,也会造成延时的错觉)这样触发防区后,应该就会即时报警了。

Q22: Vista120主机失效防区很多,我想布防我的周界。该怎么办。

A: 如果只需要布防周界的话,可以将周界编程设为24小时有声报警,布撤防都可以报警的,。就不需要旁路多个防区了。

Q23: Vista120主机可以接4100SM模块,软件可以进行远程控制吗?

A: 可以接4100SM模块,但是不能进行远程控制。如果需要可以换成IP2000可以进行远程控制。

Q24: 我的Vista120主机接了4297与4208之后,为什么不报警?

A: 您可以将4208直接接在4297前面,看是否能够正常报警,如果不行的话,那就检查4208模块的设置与编程了。

Q25: 4208模块在主机旁边编程是好的,但是放到现场去,却不行了,报Check***。这是为什么?

A: 这是您的线材问题也有可能是您将总线的正负接反了。请检查您的总线的是否连接正确?

Q26: 我使用的Vista120与4193、4293模块,但是接上探测器却会延时30秒。

A: 您先将模块不接探测器,将回路接好,让防区回路处于正常状态下。然后布防报警,测试报警是否还会延时?如果没有的话,请检查探测器这边的问题。

Q27: Vista120连接4208SN模块时需要外加电源吗?

A: 我们建议是接两个以上就要外加电源的了,如果接了多个总线模块的话,如果总的电流达到了128mA的话,就必须在加一个4297的模块了。

Q28: 4204继电器模块具体可以传输多远?

A: 用1.3平方毫米的线,可以传输500多米,而且是所有键盘总线的距离之和。

Q29: 4193SN如何接探测器?

A: 4193SN是单地址两防区的总线模块,红黑线是接主机的总线接口,绿色与黑色是2防区,白色与黑色公共端或者黄色与黑色公共端组成1防区,白色与黑色组合成的防区是需要接线尾电阻(10K)的黄色与黑是不用接电阻,1防区只能任选其一,2防区是不需要接电阻的。直接与常闭探测器相连就可以了。

Q30: 4400电子地图模块,我按照说明书的方法接好了,但是还是不行呀?

A: 这是你的拨码开关没有设置好,只要将6、7设为OFF就可以了,如果将1设为ON的话就不正常了。

Q31: 请问一下,4208SN的防区是怎么接的呀。

A: 4208SN模块是8防区模块,都支持常闭和常开的探测器,接

常闭探测器时,就要将电阻串联进去,接常开探测器,就要将电阻并联进去,电阻阻值是10K的。

Q32: 我接了一个4297延伸模块。但是接在4297模块后面的防区总是显示有问题,但是把防区移动到模块前面,就没有问题。这是什么原因?

A: 请检查4297的总线输入与输出的电压是否正常,然后将防区再重新学习一遍,如果不行的话,请将此模块返修吧。

Q33: 4100SM与IP2000是不是选一种就可以了?

A: 建议使用一种,如果需要控制主机的话,就使用IP2000,否则可以使用4100SM。

Q34: 4100SM与电脑相连时,显示OFFline,我更换了串口也不行呀。

A: 您更换串口后,在软件上也需要将串口更改才行,您也可以换一台电脑使用超级终端来检测4100SM有没有信号输出。

Q35: 4100SM的连接线是怎么做的?我的原装线丢了。

A: 您好,25针的只需要焊接2、3、7 、20、四个脚,9针的需要焊接3、2、5、4四个脚,按顺序对应排列焊接就可以了。

Q36: 你们有没有带地址码的防区模块,能远程控制的报警主机?

A: Vista120与Vista250主机都能满足你的要求了。它有总线模块:4193SN、4293SN、4028SN 都是带序列号(地址码)的。这两款主机通过IP2000可直接与电脑相连实现远程控制。

Q37: 4101SN的总线继电器,我把外盖打开了,它能够报警,但是断开电阻却不会报警?

A: 这个是模块上的有一个跳线没有断开造成的,如这个跳线没有断开的话,那就只能是接常闭探测器,不需要接电阻了。

⑦软件与软件和附件的配合问题

Q1: 我的Vista120主机为什么可以使用IPAlarm软件控制主机,但是主机报警后,IPAlarm软件却收不到信息。

A: 特别注意电脑的防火墙要关闭。另外,IP2000要正确连接才行,请检查你的IP2000的接线是否正确,IP2000上的灯是否在亮绿灯,然后在电脑端ping一下IP2000的IP地址,如果连通了,请检查主机的设备编程及1*70至1*73编程是否编好,。在IPAlarm软件里也得需要设置,得在设备管理项增加设备,以上都做好了的话,就可以了,如果还是不行的话请将IP2000发到我公司检测。

Q2: 我使用的是Vista 120主机,分了3个子系统,使用的是IPAlarm软件,怎么不可以使用?

A:这个软件得需要设置,分了3个子系统,每个子系统得分配一个用户。还得添加设备。具体的可以根据说明书来设置。

Q3: 三套IPAlarm-4,主机报警后与电脑无法连接,软件上无反应,这是为什么?

A:请检查4100SM模块是不是有信号输出,您可以使用系统自带的超级终端来测试4100SM模块是否好的。如果有输出就检查软件的设置问题,没有的话,请检查1*70-1*173的编程,及主机与模

Honeywell霍尼韦尔

UniSim流程设计与动态仿真 1 流程行业过程设计与动态仿真的重要性与挑战 现代化的炼油和石化工装置对自动化控制系统的要求越来越高。随着DCS、先进控制技术、优化技术、计划与调度等先进技术的广泛应用,工厂生产自动化程度越来越高。要对装置和工艺过程进行有效的操作和控制,在选用控制策略和制定操作规程时必须全面考虑到工艺原理、过程动态特性以及各个控制对象之间约束等诸多关系。这对于装置工程师、控制工程师、生产操作人员来说是一个巨大的挑战,因为他们必须在较短时间内掌握这些先进的控制技术,熟悉调节控制的方法,全面掌握工艺过程原理及动态特性等一系列与生产操作相关的知识。如果能在正式开车之前给他们提供适当的培训,让他们充分熟悉工艺和操作规程,积累操作经验,这将非常有利于生产装置顺利投运,有利于稳定安全的生产,有利于发挥装置的最大能力,真正给工厂带来效益。 但是,装置工程师、控制工程师、生产操作员如何能在系统投运前尽快地熟悉工艺过程、获得全面的操作体验和提高处理异常事故的能力呢?传统方式主要有三种:开工前DCS短训、学习操作规程和外出实习。无论采用何种方式,所获得的知识和经验都是十分有限的。在装置开工前,DCS短训时间有限,工艺本身又未投运,所以只能做到熟悉操作界面和基本操作而已,对于复杂的控制策略、先进控制器的投用、操作程序等,操作员都无法真正体验;学习操作规程全无感性认识,就如同我们只是拿着书本学习电脑,而却没有电脑可用,效果自然不会好;外出实习,首先所学的不是用户自己的工艺,其次,在实习装置上,操作人员不可能实际操作和经历各种工况,三是操作人员不可能接触到那些核心工艺,况且还要必须支付大量的实习费用。 此外,虽然目前针对流程行业流程设计与动态仿真的应用已经非常普遍,但从专业机构的调查统计来看,仍然存在一些问题和挑战。例如,市场上有不少产品系统平台的物性库不够丰富并缺少权威性、稳态设计达不到应用精度、动态仿真特性偏离性大、不能对DCS/ESD等系统进行完全识别和兼容、对大过程模型无法实现全流程动态模拟等等。 2 Honeywell综合解决方案-UniSim 霍尼韦尔基于流程行业上述这些需求,经过三十年来的开发与应用,特别是在2004年成功收购ASPEN公司的仿真业务后,公司将原有的动态仿真系统SHADOW PLANT,OTISS 与HYSYS整合,形成了集流程设计、静态模拟、动态仿真、过程优化于一体综合解决方案和产品架构-UniSimTM,在技术平台的先进性,模拟应用经验的广泛性,成功实施案例和工程实施队伍的规模,技术支持能力等各个方面都得到空前的加强,在国际OTS业务中由原来的领跑者变成了占有绝对优势的主导者。 UniSimTM工艺过程设计与动态仿真工具,致力于帮助用户全面地熟悉自己的生产装置和工艺,掌握动态工艺特性,积累操作经验,提高处理异常事故的能力,保证生产装置的顺利投产,维护正常的生产操作。UniSimTM 不是一般意义上的稳态过程模拟,它是全面的动态过程仿真。UniSimTM 基于精确的热动力学方程和传质动力学模型,因此它成为了一套公认的可以帮助工程师研究探索工 艺过程、进行工况研究、发现工艺瓶颈、寻找最佳操作程序、进行故障分析和控制策略研究的工具,也成为了帮助工厂操作人员积累操作经验、熟悉工艺、提高操作技能的培训工具。 UniSimTM是一套关系到过程设计、工艺瓶颈分析、动态仿真、工况研究、操作方案论证、控制策略确认与调试、生产优化、装置改造等完整贯穿整个工厂装置生命周期的综合解决方案。

Honeywell China Brochure 霍尼韦尔中国

HONEYWELL CHINA

我们正在建立一个更安全……更舒适、更节能……更具创新力和生产力的环境。我们是霍尼韦尔。 We are building a world that's safer and more secure...More comfortable and energy efficient...More innovative and productive.We are Honeywell.

中国CEO致辞 CHINA CEO MESSAGE 当今的中国,正在成为全球经济增长的中心。经过过去短短三十年的飞速发展,中国国民生产总值的增长超过了十倍,迅速占据了世界经济舞台的重要地位。 目前,中国政府正在推动“十一五规划”,确保经济的持续发展。霍尼韦尔愿意与中国政府共同努力,利用我们的核心竞争力帮助落实“十一五规划”,降低能耗,减少污染,发展制造业,改善基础设施,同时确保人民的健康和安全。 通过针对中国市场的需求提出本地化解决方案,霍尼韦尔已经成为了行业创新的领头羊。“东方服务于东方”的战略见证了我们通过本土科 技人才进行技术创新的飞跃。同时, “东方服务于西方”的战略则进一步 指引我们将本地的创新成果推广到全 球市场,从而使中国成为霍尼韦尔业 务增长和科技创新的一大支柱。出色 的中国业绩对于霍尼韦尔真正成为一 家跨航空航天、自动化控制、交通系 统和特殊材料四大业务领域的全球化 企业而言至关重要。 霍尼韦尔的解决方案被应用于生 活的方方面面。我们出色的业绩源自 高质量的产品和高效的服务。我们在 全球优势行业的领先地位一直推动着 在华业务的增长,并使中国成为了霍 尼韦尔最大的市场之一。这种成功并 不局限于我们的业务领域,我们还在 中国开展了众多成功的企业社会责任 项目。所有这些努力都体现了霍尼韦 尔对中国构建和谐、可持续发展社会 的坚定承诺。 通过我们出色的管理团队的努 力和合作,我们将继续撒播成功的种 子,凭借独特的愿景和强大的创新能 力在未来取得更大的成功。 沈达理 总裁兼首席执行官 霍尼韦尔中国和印度 China has been moving toward the center stage of the global economy. This great nation has arrived at this prominent position after three short decades of rap- id development and a tenfold increase in GDP. Today, the Chinese government is working hard to ensure the entire nation can sustain this era of progress through the implementation of the 11th Five- Year Plan. This plan and Honeywell’s key competencies focus on reducing energy consumption and pollution, revitalizing the manufacturing sector and improving the nation’s public infrastructure while en- suring the population’s health, safety and security. By addressing China specific chal- lenges with China specific solutions, Hon- eywell has become a leader in domestic innovation. Our “East for East” initiative has resulted in a rapidly increasing num- ber of concepts and technologies being developed in China, rather than imported from abroad. China is a pillar of Honey- well’s globalization, growth and innova- tion strategy. Our “East to West” initiative has significantly boosted the export of domestic innovations to markets around the world. The success of our China op- erations is critical in making us a truly global company across all four of our businesses – Aerospace, Automation and Control Solutions, Transportation Systems and Specialty Materials. Through these businesses, Honey- well creates solutions that can improve many facets of life. We create products and services with the highest quality and value and deliver them to our customers on time. Our great positions in good in- dustries have driven growth across each of our four business segments, and have made China one of Honeywell’s largest markets. This success is not limited to our business operations; we have also in- vested in numerous successful Corporate Social Responsibility programs across China. All of these activities, whether commercial or philanthropic, represent Honeywell’s unwavering commitment to the China market and contribute to the building of a harmonious and sustainable society in this great nation. Through the hard work and commit- ment of our strong management team, we will continue to sow the seeds of success and reap the harvest of greater achieve- ments in the future, a future guided by our focused vision and industry-leading innovations. Shane Tedjarati President and CEO Honeywell China and India 霍尼韦尔中国管理团队 Honeywell China Management Team

Honeywell(霍尼韦尔)1900条码扫描枪设置

本文讲述Honeywell(霍尼韦尔)1900条码扫描枪设置方法和常见问题解决,包括出厂设置和 后缀设置等。——鸿兴永利条码 Honeywell(霍尼韦尔)1900条码扫描枪是一款二维扫描枪,Honeywell1900的图象传感器设计是专为条码扫描而研发的,对于条形码标签的扫描拥有行业中领先的阅读性能和可靠性。 Honeywell(霍尼韦尔)1900扫描枪后缀设置 如何让Honeywell1900扫描枪在扫描条形码后出现一个回车符?可以用扫描枪直接扫描“添加回车符后缀”的条形码,就可以实现添加回车符的功能;Honeywell1900扫描枪添加制表符方法:直接扫描“添加制表符后缀”条形码便可以轻松实现此功能,如果不需要添加后缀,可以扫描“删除后缀”条形码。 当您在使用HONEYWELL 1900条码扫描器时,如果您希望HONEYWELL 1900GHD扫描器在扫描条码后出现一(扫描下方相对应条码设置)

在使用Honeywell1900扫描枪过程中,如果出现某些编程选项的错误,想通过恢复出厂设置来解决的话,就可以通过一下方法来解决: 1.先用Honeywell1900扫描枪扫描“Remove Custom Defaults”条形码, 2.扫描“Activate Defaults”条形码,这个时候Honeywell1900条码扫描器将恢复到最开始的设置也就是出厂设置。 (1) (2) Honeywell(霍尼韦尔)1900扫描枪常亮模式设置 一般Honeywell1900扫描枪模式的设置有三种:1.自感应扫描模式;2.手动触发扫描模式; 3.常亮扫描模式的设置。一下是相对应的扫描模式的条形码设置,只需用扫描枪扫描对应条形码就能实现相应功能设置。 常亮扫描模式 手动触发扫描模式 自感应扫描模式

霍尼韦尔VISTA-128BPT编程说明(详细对照)

Honeywell 霍尼韦尔 VISTA系列报警主机编程说明 深圳市麦驰物联股份有限公司 工程服务部-整理编辑

目录 一、设备认识 (3) Vista系列报警主机(以Vista 128BPT为例) (3) Vista系列报警主机控制键盘(6160) (7) 4193SN/SNP单地址码两回路模块(已停产) (7) 4293SN单防区扩充模块 (8) 4101SN V-Plex单防区总线继电器模块 (9) 4204ECP总线继电器模块 (9) 4208SN V-Plex总线8防区扩充模块 (10) 4297总线延伸器 (10) 4232AP 32路继电器模组 (12) VPlex-VSI总线监测/隔离模块 (13) IP-2000 2.0网络接口模块 (14) 二、主机编程 (17) 防区编程: (17) 删除防区: (21) 子系统编程: (23) 1.子系统数量划分: (23) 2.子系统跳转功能设置: (23) 3.防区子系统划分及布防延时更改 (24) 继电器输出设备编程: (25) 1.4101SN单防区继电器模块编程 (25) 2.防区列表编程 (29) 3.查看防区列表 (30) 4.4232AP 32路继电器模块编程设置(VISTA 128BPT) (30) 4100SN与IP2000模块编程: (31) 三、键盘日常使用操作 (33) 1.布撤防操作 (33) 2.子系统跳转 (33) 四、主机常见问题解析 (34) 五、键盘常见显示中英文对照 (36)

一、设备认识 Vista系列报警主机(以Vista 128BPT为例) (图1) 由原安定宝、C&K打底建立的Honeywell安防是全球最大的报警器材制造商,其制造的VISTA系列报警主机(图1)是业界最早、认可度最高的大型总线制报警主机,主要用来接收处理前端探测器发送回来的报警信号,是先进的多功能控制主机。 功能框图

霍尼韦尔honeywell VISTA120中文说明书

霍尼韦尔honeywell VISTA120中文说明书 1.产品以及系统的技术指标以及功能 VISTA-120可以划分为8个子系统,最多支持128个由有线、总线或无线设备组成的防区,主要性能如下: ·对于5800EU系列无线设备,可以监测无线干扰,支持无线警号,监测时间缩短。 ·通过对4101SN 和4208UXM Mk3 的支持,继电器数量从32个增加到96个。 ·增加了和PASSPOINT门禁系统的互动功能。 ·支持自驱动警号。 ·支持最终触发布防。 ·系统布防时可选下载限制。 ·防区9可用于电话线监测处理。 ·可选择布撤防期间键盘的不同显示。 ·对于序列号式总线设备支8倍的数据处理速度。 ·防区列表数量从8个扩展到15个。 ·可选择每个子系统可以被旁路的防区数量。 基础接线防区 ?防区2-8可选末端电阻监测,支持NO或NC探测器 ?可以划分到任一子系统 ?防区1可以支持最多16个烟感探测器 ?防区1-8都可以使用4线烟感探测器

?防区8最多支持50个玻璃破碎探测器 总线防区扩展: 支持119个总线防区,最大电流128mA: ?必须使用总线模块(RPM) ?受主机监视 ?可以划分到任一子系统 无线防区扩展: 用5800系列无线设备最多可以有128个无线防区(若同时接有有线或总线防区,无线防区相应减少): ?发射器发送安全信号供主机监视 ?可以监测发射器的电池状态 ?可以划分给任意一个子系统 特殊监视防区 J7 触发器输出防区973 无线接收机防区988, 990 总线回路防区997 外围设备 支持最多32 和6139/5839EU 键盘混合连接的可编址设备,如无线接收机、继电器模块、4285电话模块等: ?与键盘接在同一接线柱 ?每个设备一个唯一的地址

霍尼韦尔 Honeywell安防系统快速指南

PREK5966CH 4/07 Rev. A ADEMCO LYNXRIEN-CH 安防系统 快速指南 概述 本快速指南通过使用默认安装设置,提供安装的基本操作步骤,可以帮助您简单快捷地安装可充电LYNXRIEN-CH。需要更多详细信息和重要提示,请参考LYNXRIEN-CH安装指南。 安装LYNXRIEN-CH 安装和电路连接 步骤动作 1. 如下安装控制器: a. 从底板上分离出前面板,并从前面板上拔下电缆 提示:切勿从电路板上的对外连接器上拔下带式电缆,只能从主机前面板拔下电缆。 b. 安装后盖. 2. 按如下步骤进行线路连接: a. 将拨入电话线连接到8位置插孔或端子2(TIP)和3(RING)。 b. 将手提电话线连接到RJ11插孔或端子4(TIP)和5(RING)。 提示:对于完全线路抢占,请查阅安装说明 c. 如果使用,请将压电轰鸣器连接到端子10(+)和11(-) d. 如果使用,请将闹铃连接到端子11 (–)和12 (+). e. 将交流变压器的导线连接到端子15和16. 3. 按如下步骤连接电源: a. 取下电池固定器。 b. 从底板上的胶带上撕下陈片。 c. 将电池组插入底板。 d. 安装电池固定器。 e. 将电池接头插入接线印刷电路板上的插座。 f. 小心地将带状电缆重新连接到主机前面板接头上(正确对准红线)。 g. 所有线路连接完毕后,将主机前面板卡入底板,使其被卡扣固定。 h. 将变压器插入一个 24 小时 220V交流无开关插座。 注: 充电式电池组需要 48 小时来充足电。在四小时内或进入测试模式时,“电池低电压”信息会消失。

LYNXRIEN-CH 线路连接

霍尼韦尔(honeywell_pks)详细操作详解(含大量实操图).docx

实用标准 1、容错以太网是PKS 的控制网络, FTE 不但提供了容错的特点,也提供了快速网络的相应,及工业以太网的控制应用的安全性。FTE(Fault Tolerant Etherent)容错以太网,是冗余网络结构的单网,通过Honeywell的FTE驱动,及商用的网络设备实现的。 FTE 网络包括冗余的交换机和电缆。 拓扑:双重并行树形网络在顶部接在一起。 2、交换机之间的级联线(cross link )构成单网。商用的网络设备指交换机、双口单网卡或单口双网卡。 FTE 网络通讯检测画面 检测画面启动

3、系统必须有控制器、服务器、操作站组成。 4、FTE 网络包括冗余交换机和电缆。 树网:连接到 A 交换机上 A 口形成的网叫 A 网(Yellow tree )。 连接到 B 交换机上 B 口形成的网叫 B 网( Green tree )。 Localhost接收数据节点。 FLEX 操作站( F 站):过程数据及相关的报警和事件,还有其他数据信息,直接来自服务器; 组态 ES-F 两种连接方法:固定连接方法(Static ):提供了特定ES-F 的一种永久性专用连接。轮替连接方法(Rotary ):提供了一种按需的连接,适用不需要全日制操作访问时。 Console操作站(C站):过程数据及相关的报警和事件,直接 来自于控制器;其他数据信息来自于服务器; Console Extension操作站(CE):过程数据及相关的报警和事件,还有其他数据信息,全部信息都来自与 C 站。 7、一个 C300 控制器带有两个IOLINK ,每个 IOLINK 最多支持 40 个 IO 卡件,而一个控制器最多支持 64 个 IO 卡件。每套 C300 控制器最多支持 64 个 IO Units (IOU )。C300 控制器必须与控

honeywell霍尼韦尔报警主机简易编程要点

236主机编程速成 一、操作: 布防、撤防:密码#旁路:密码 旁区号 # 取消记忆:*1#复位:密码*68#关键盘音:*51# 例如: 布防、撤防:1234#旁路:12343 # 取消记忆:1234*1#复位:1234*68#二、编程: 1.进入编程:012345*0 # 2.退出编程:* # 3.密码部分:01__ __ __ __ # 密码必须四位 ……

4.通讯部分: 0A5353# 0 B #0 C #0 D E0000 # 0 F #10E0000 # 12 # 13E0000 # 5. 一防区1D 二防区1E111220 # 三防区1F111220 # 四防区20111220 # 五防区21111220 # 六防区

22111420 # 一、操作: 布防、撤防:密码#,旁路:密码 取消记忆:*1# ,复位:密码*68# 例如:布防、撤防:1234#旁路:12343 # 取消记忆:1234*1#复位:1234*68#二、编程:1.进入编程: 2.退出编程:* # 3. 密码部分:01密码开头必须为1,写够5位,若为4位, 以*4作为1位结束; ……

4. 通讯部分: 00014 __ 前6位 __ 15第7位E00005. 防区部分: 五防区23 1 2 1 __ __ 3 # 六防区24 1 2 1 __ __ 3 # 七防区25 1 2 1 __ __ 3 # 八防区26 1 2 1 __ __ 3 # 一、操作: 布防、撤防:密码#,旁路:密码 # (bypass为右下角的键取消记忆:*1# ,复位:密码*68# 二、编程: 1. 进入编程: 012345*02.退出编程:* #

honeywell介绍

详细资料请查看:https://www.doczj.com/doc/98560393.html,

世界500强跨国集团

?????????
1885年,Al Butz 开发了熔炉控制系统,将此系统作为产品成立公司 1886年,发明世界上第一个温控器,成立Butz 电子温度调节器公司 1893年, 更名为电子供热调节器公司(HER) 1906年,马克 · 霍尼韦尔的年轻人创立了霍尼韦尔特种加热器公司 1921年,EHR公司更名为明尼艾普利斯公斯供热调节器公司(MHR) 1927年,MHR公司和霍尼韦尔特种加热器公司合并,组成明尼艾普利斯。霍尼韦尔 调节器公司 从此开始了在控制领域购并企业及在全球扩展业务 调节器公司,从此开始了在控制领域购并企业及在全球扩展业务 1929年,公司公司股票上市 1963年,公司正式更名为霍尼韦尔公司 1969年,霍尼韦尔的仪表帮助美国宇航员首次成功登月 1974年,霍尼韦尔研制开发了世界上第一套集散控制系统(DCS), 并成为一种 规范沿用至今 1998年,霍尼韦尔营业收入达到84亿美元 1999年,霍尼韦尔与美国联合信号公司合并,合并后公司仍称为霍尼韦尔 年 霍尼韦尔与美国联合信号公司合并 合并后公司仍称为霍尼韦尔

?????????///
全球 100个国家拥有12万员工, 总部设在美国新泽西州莫里斯镇 年销售额超过346亿美元 著名 30 家道琼斯股指公司之一,“标准普尔 家道琼斯股指公司之 “标准普尔500指数”的组成部分 排列《财富》杂志前50位 被《财富》杂志(1999)评为“工作最适” Best to Work For 公司 被《工业周刊》(1999) 评为 “最佳管理公司” 最佳管理公司 Best Managed Companies, 被 《福布斯》评为 “世界第一多元化公司”






全球超过1亿的家庭或大楼使用霍尼韦尔的楼宇控制产品 全球第一流的专利拥有者 全球第 流的专利拥有者


honeywell控制方案

Honeywell(霍尼韦尔)建筑自动化系统Honeywell(霍尼韦尔)是一家以高科技与生产制造,服务的多元化跨国公 司,99年销售二百四拾亿美金,Honeywell提供全球的控制产品和服务,主要包括航空航天控制、建筑自动化控制、家用住宅与工业自动化控制的产品。公司在全球拥有12000员工,在纽约交易所、伦敦、芝加哥与大洋州等交易所上市,排列道琼斯前30位,被评为标准普尔500指数。 Honeywell(霍尼韦尔)建筑自动化系统为客户制造提供高效、安全、舒适的环境、产品及服务,控制系统主要包括供暖、通风、及空调系统的控制设备、保安与火警系统、家庭自动化及照明控制与建筑管理系统和服务。Honeywell(霍尼韦尔)XBS建筑自动化系统 Honeywell(霍尼韦尔)公司凭借充分和完善的研究发展计划,不断推出创新可靠的高技术产品和软件,其所有的产品的设计、制造都达到同行业最高的质量等级标准。同时售后服务也不断获得用户的信赖和好评,一直处于世界领先地位。 一. 系统概述 1. 控制管理和监视以及能源节约 Honeywell(霍尼韦尔)EBI建筑自动化系统集成了Honeywell(霍尼韦尔)公司百年来在的楼宇、厂房的HV AC加热、通风、空调的最先进产品和最新的计算机控制技术,提供监视大区域内从一座楼到大量建筑物的设备。用户可以详细地看到并控制建筑的远行管理,完全控制HV AC、照明、火警、安保等等。Honeywell(霍尼韦尔)EBI建筑自动化系统的应用能使源利用率和设备的运行使用达到最理想的状态。由于他能减少设备运行费用,优化设备使用性能和使用寿命,将为业主节省相当可观的运行费用。 2. 最先进的人机接口 Honeywell(霍尼韦尔)EBI建筑自动化系统应用于Windows NT接口,遵循现有工业标准,先进的“即插即用”控制系统,提供Windows环境下常用的下拉式菜单和会话对话框,操作简明易懂,现场设备的任意接点出均可使用现场显示终端对设备进行操作。 3.动态现场图示 控制系统中所有控制工况和场景均可动态的在监控中心显示,每一个现场工况为三维彩色图形都是动态连接在相关控制点上,如果连接的系统或组成部分或组成部分或是来自者的信号改变了,它们也随之改变。 供面向对象的彩色图象界面,在专用的操作环境中进行控制、监视和管理。彩色图象不仅能清楚地显示整个系统的布局,还能显示记录图象和三维物体。 用彩色图象还可以方便地进行系统的控制和监视。在每一个图象中动态连接区域都分级与其它图象连接。通过这些连接,可从整体上看到建筑布局、楼层规划或空调器、变压器等其它连接对象。

Honeywell霍尼韦尔的品牌资质分析报告

“Honeywell霍尼韦尔”品牌资质分析报告 尊敬的用户: 随着经济全球化的深入发展,各市场领域的竞争已逐渐表现为品牌竞争。根据中国互联网络信息中心(CNNIC)公布的最新数据显示,中国网民规模已达8.02亿,互联网普及率57.7%。而网民规模增长的推动力正是由于互联网商业模式的不断创新以及线上线下服务融合的加速,因此,互联网时代的到来也意味着网络品牌标识的价值提升。习总书记不断强调知识产权战略的重要性,同时每年5月10日“中国品牌日”的确立也标志着品牌建设与保护已经刻不容缓。 根据您查询的“Honeywell霍尼韦尔”品牌,及“制造业-医疗器材,制造业-体育用品,制造业-机器机械,制造业-服饰配饰,制造业-电子产品,商务服务-市场营销,网络服务-网络建站,网络服务-软件开发,网络服务-网络通讯,制造业-家用电器,居民服务-消防,制造业-电气器材”行 业,Honeywell霍尼韦尔的品牌分析报告如下: 目录 一、Honeywell霍尼韦尔品牌商标分析 1、行业注册分析 1.1 制造业-医疗器材行业注册分析 1.1.1 制造业-医疗器材行业品牌注册量 1.1.2 Honeywell霍尼韦尔品牌在制造业-医疗器材行业的主要注册情况 1.1.3 制造业-医疗器材行业下Honeywell霍尼韦尔同名品牌的主要竞争对手 1.2 制造业-体育用品行业注册分析 1.2.1 制造业-体育用品行业品牌注册量 1.2.2 Honeywell霍尼韦尔品牌在制造业-体育用品行业的主要注册情况 1.2.3 制造业-体育用品行业下Honeywell霍尼韦尔同名品牌的主要竞争对手 1.3 制造业-机器机械行业注册分析 1.3.1 制造业-机器机械行业品牌注册量 1.3.2 Honeywell霍尼韦尔品牌在制造业-机器机械行业的主要注册情况 1.3.3 制造业-机器机械行业下Honeywell霍尼韦尔同名品牌的主要竞争对手 1.4 制造业-服饰配饰行业注册分析 1.4.1 制造业-服饰配饰行业品牌注册量 1.4.2 Honeywell霍尼韦尔品牌在制造业-服饰配饰行业的主要注册情况

honeywell霍尼韦尔 1500G二维条码扫描器参数

honeywell霍尼韦尔1500G二维条码扫描器 名称:Xenon 1500G 特征:Xenon 1500G系列是Honeywell采用第6代影像技术的一款扫描枪,它的发布重新定义了手持扫描枪的标准.因为采用了专为条码扫描而开发的图象传感器, Xenon 1500G拥有了行业中领先的阅读性能和可靠性,可适用于各种应用场合。 产品说明: 定制的图象传感器,优化了扫描性能—提升了扫描性能;稳定的供应链,确保产品可长期服役,保护客户的投资。 多种型号可选—针对不同的应用场合,Honeywell提供三种焦距型号(高密度,标准范围和延程型)产品供客户选择。 可选医用外壳—外壳更加坚固能够抵御清洁剂等化学试剂的侵蚀。 图象处理软件—提供了先进的编辑功能—裁剪,增亮,旋转,锐化等等-从而提供更高质量的图象。 TotalFreedom? 2.0第二代开发平台—扫描枪可装载和连接多个应用程序,提高图像处理、数据格式编辑和解码功能,无需连接到主机系统即可操作。 R emote MasterMind? 扫描设备管理软件—为实现从单一远程站点来管理所有扫描器的IT管理人员提供快捷的解决方案。 Xenon1500G 性能快速一览表 扫描角度高密度HD:水平41.4°;垂直32.2° 标准距离SR:水平42.4°;垂直33° 长距离ER:水平31.6°;垂直24.4° 可识别反射对比度最低20%的反射差 解码能力可读取标准一维、堆叠、二维条码和邮政码以及特定的OCR字符 扫描模式二维影像(838X640像素排列) 工业等级IP41 尺寸104mm*71mm*160mm 系统接口RS232串口, IBM 468XX(RS485), 键盘口, USB 抗摔强度可承受1.8米的反复跌落(至混凝土地面) 重量 147g 抗抖动性性 最佳焦点处扫描13milUPC条码可达到610cm/秒(240英寸/秒)

霍尼韦尔产品全部资料

目录 技术部分 (1) 一、霍尼韦尔安防(Honeywell Security)简介 (1) 1、霍尼韦尔公司简介 (1) 2、霍尼韦尔安防(Honeywell Security)发展历程 (2) 3、典型项目案例 (3) 二、门禁控制系统设计 (7) 1、门禁系统构成 (7) 2、门禁控制管理软件(Winpak Pro) (10) 3、门禁设备参数 (14) 技术部分 一、霍尼韦尔安防(Honeywell Security)简介 1、霍尼韦尔公司简介 霍尼韦尔是一家营业额达到340亿美元的财富100强企业,而安防事业在

其多元化经营中占据着特殊的地位。过去两年,霍尼韦尔战略投资中相当一部分用于发展安防事业。我们还致力于将其他霍尼韦尔业务中的资源与安防事业整合起来,我们提供给您的是霍尼韦尔全部的品牌优势! 霍尼韦尔安防是全世界最大及最富经验的电子保安系列产品制造商之一,其产品正保护着全球数百万的家庭、企业单位、商业单位及政府机关的安全。 霍尼韦尔安防不仅在工业领域,同时在商业领域也凭借其最先进的技术保护着各类场所的安全,通过提供品质卓越的视频监控系统、防盗控制系统、门禁控制系统及功能完善的集成系统,使霍尼韦尔安防产品能够配合不同的安装需求。确保着全球工业的未来并令我们的商业环境、生活环境更加安全! 霍尼韦尔安防产品品牌处于全球领先地位。全球安防行业的权威性杂志《安全与自动化》在2004年1月进行的广泛的网络调查的基础上评选出十大安防品牌,霍尼韦尔安防是唯一一家在三大产品类别中评选得分领先并排名前五位的品牌。 霍尼韦尔安防信守对经销商、系统集成商的承诺。我们关注如何促进合作伙伴的业务增长,并投资于那些可助您成长的项目。我们不断深入挖掘市场需求并创造需求,为您搭建成功的舞台。我们深深懂得:只有您成功,我们才能成功! 霍尼韦尔安防不断追求创新,提供新技术、新产品。霍尼韦尔安防每年在研发方面投入超过4000万美元,通过设在中国、美国、韩国、印度、苏格兰和法国的研发基地,我们能为您提供全球最好的技术。在中国,我们针对安防市场成立了专门的研发部门,第一时间响应中国用户的需求。 我们聘用最好的员工为您提供支持与服务,霍尼韦尔安防只聘用最优秀的员工为您提供支持,以确保您走在前列。在中国,我们更让最熟悉中国市场、最了解中华民族人文的优秀人才与您实现无缝交流。 2、霍尼韦尔安防(Honeywell Security)发展历程 1980年代- 进入中国市场 1990年代- 收购WSE(西屋,现名为Nexwatch) 90年代中后期- Ademco(安定保)收购Javelin(标枪)、

霍尼韦尔(Honeywell)键盘控制码及控制协议

Honeywell 键盘控制协议串口参数: 115200,7,E,1 每个功能项由以下字符序列组成的控制码,如下图:

监控器:61 *801K0,61,1 *801K0,61,0 摄象机:73 *801K0,73,1 *801K0,73,0 预置位:74 *801K0,74,1 *801K0,74,0 回车:76 *801K0,76,1 *801K0,76,1 轮巡:3 *801K0,3,1 *801K0,3,0 轮巡停止:4 *801K0,4,1 *801K0,4,0 轮巡暂停:5 *801K0,5,1 *801K0,5,0 设置:15 *801K0,15,1 *801K0,15,0 数字1:62 *801K0,62,1 *801K0,62,0 数字2:63 *801K0,63,1 *801K0,63,0 数字3:64 *801K0,64,1 *801K0,64,0 数字4:66 *801K0,66,1 *801K0,66,0 数字5:67 *801K0,67,1

*801K0,67,0 数字6:68 *801K0,68,1 *801K0,68,0 数字7:70 *801K0,70,1 *801K0,70,0 数字8:71 *801K0,71,1 *801K0,71,0 数字9:72 *801K0,72,1 *801K0,72,0 数字0:75 *801K0,75,1 *801K0,75,0 云台向上:96 *801K0,96,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,96,0 停止 云台向下:97 *801K0,97,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,97,0 停止 云台向左:98 *801K0,98,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,98,0 停止 云台向右:99 *801K0,99,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,99,0 停止 Zoom IN :86 *801K0,86,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,86,0 停止 Zoom Out :87 *801K0,87,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,87,0 停止 Focus Far :88 *801K0,88,1 开始,最后的1表示速度,可以用1-5 , 5最快,1最慢*801K0,88,0 停止

霍尼韦尔(honeywell_pks)详细操作详解(含大量实操图)

1、容错以太网是PKS的控制网络,FTE不但提供了容错的特点,也提供了快速网络的相应,及工业以太网的控制应用的安全性。FTE(Fault Tolerant Etherent)容错以太网,是冗余网络结构的单网,通过Honeywell的FTE驱动,及商用的网络设备实现的。 FTE网络包括冗余的交换机和电缆。 拓扑:双重并行树形网络在顶部接在一起。 2、交换机之间的级联线(cross link)构成单网。商用的网络设备指交换机、双口单网卡或单口双网卡。 FTE网络通讯检测画面 检测画面启动

3、系统必须有控制器、服务器、操作站组成。 4、FTE网络包括冗余交换机和电缆。 树网:连接到A交换机上A口形成的网叫A网(Yellow tree)。连接到B交换机上B口形成的网叫B网(Green tree)。Localhost 接收数据节点。 FLEX操作站(F站):过程数据及相关的报警和事件,还有其他数据信息,直接来自服务器; 组态ES-F两种连接方法:固定连接方法(Static):提供了特定ES-F的一种永久性专用连接。轮替连接方法(Rotary):提供了一种按需的连接,适用不需要全日制操作访问时。 Console操作站(C站):过程数据及相关的报警和事件,直接来自于控制器;其他数据信息来自于服务器; Console Extension操作站(CE):过程数据及相关的报警和事件,还有其他数据信息,全部信息都来自与C站。 7、一个C300控制器带有两个IOLINK,每个IOLINK最多支持40个IO卡件,而一个控制器最多支持64个IO卡件。每套C300控制器最多支持64个IO Units(IOU)。C300控制器必须与控

honeywell霍尼韦尔T9275A操作说明

Honeywell - T9275A操作说明 1、开机前请确认接线及24电源 2、第一次送电LCD显示OFF(有DIGIT IN)或OPEN(无DIGIT IN),有DIGIT IN时按SELECT键3秒后开机,进入操作使用状态,若无DIGIT IN,请确认是否将DI短路。 3、开机后按UP或DOWN键,可设定温度1℃(连续按2秒,连续快速变化)按ENTER键一次,数字闪烁表示完成。 4、按SELECT键,选取其他功能再按UP或DOWN更改,再按ENTER键即存储。 5、按SELECT键至SENSOR显示,0表示内置传感器,1表示外置传感器。予设为0。 6、按SELECT键至MODE显示:予设为0。 AO为制冷工况,DO× AO为加热工况,DO× AO为制冷工况,DO为加热工况 AO为加热工况,DO为制冷工况 AO为制冷工况,DO为LOW TEMP.LIMIT AO为加热工况,DO为HIGH TEMP.LIMIT 7、按SELECT键至MANUAL显示,0表示自动控制,1表示手动输出控制(0-100%)。予设为0。 8、按SELECT键至DISPLAY显示,0表示LCD上方显示环境

温度,下方显示设定温度,1表示LCD上方显示输出百分比,下方显示环境温度。予设为0。 9、按SELECT键至F1显示(积分时间)予设为15秒,范围:0.1-60秒。 10、按SELECT键至F2显示(高低温报警)予设为30℃,(SENSOR 0时,10-60℃)(SENSOR 1时,-20-110℃)。11、按SELECT键至OFFSET显示(温度补偿校正)予设为0℃,范围:-3℃-+3℃。 12、按SELECT键至PBAND显示(比例带),予设为2℃,范围:2℃-19℃。 13、按SELECT键至DIFF显示(动作偏差),予设为0℃,范围:0℃-3℃,同时使用制冷及加热(电热)时,其中一点DO控制时,可设定DIFFERENTIAL VA LUE使温度控制于偏差范围内。 14、按SELECT键至ZBAND显示(零能源带),予设为1.5℃,范围:1.5℃-3℃,同时使用制冷及加热(电热)时,本功能才有作用,温度在ZBAND范围内,不做控制。

霍尼韦尔Honeywell 1900ghd二维条码扫描枪的程序问题

霍尼韦尔Honeywell 1900ghd二维条码扫描枪的程序问题 作者:扫描网文章来源:https://www.doczj.com/doc/98560393.html, 霍尼韦尔HONEYWELL 1900GHD扫描枪是目前二维条码扫描枪里面性价比最高的一款设备之一,它具有扫描速度快,扫描准确度高,数据传输速度快,价格相对较低等特点,全黑的外壳设计,人体工学的手柄,能满足各种行业对二维条码扫描的需求。 HONEYWELL 1900GHD扫描枪是霍尼韦尔公司领先的第六代二维影像条码扫描仪,重新定义了手持式扫描枪的标准。采用专为条形码扫描而特制的传感器,HONEYWELL 1900GHD扫描枪在一系列二维影像技术应用中均有行业领先的性能与可靠性表现。Adaptus6.0影像处理技术使得Xenon1900系列在条形码扫描和数字影像捕捉方面具有一流的性能。此外,集成包括Adaptus5.5影像处理技术和Omniplannar’sSwiftDecoder软件在内的革命性创新解码机制,并同时配置特质传感器,HONEYWELL 1900GHD扫描枪的扫描范围宽大,阅读速度极快,在扫描破损条码的能力方面显著增强。 HONEYWELL 1900GHD二维条码扫描枪经历了几次升级更新,那么就出现了HONEYWELL 1900GHD二维条码扫描枪与程序兼容性问题,如果兼容性出现了问题,在使用中就会遇到各种看起来很是奇怪的状况。 比如:最典型的状况就是条码扫描枪在扫描条码的时候,条码扫描枪提示音正常,但是数据无法上传电脑;还有就是条码扫描枪在扫描条码时提示音是短促的发闷的声音,这种也是较常见的状况。 针对条码扫描枪扫描条码无法上传的问题,我们可以通过条码扫描枪设置手册上的设置条码进行简单设置,我们可以扫描一下恢复出厂设置条码,然后再用扫描枪扫描一下对应的接口方式条码,此时一般可以解决问题了。 如果把HONEYWELL 1900GHD条码扫描枪重新插拔以后状况依旧,那么可以判断是因为扫描枪的程序版本问题,才导致刚才的设置没有成功保存,此时我们需要对条码扫描枪重新刷一下程序。到Honewell官方网站上面下载一个名字叫做“EZConfig_Scanning_V ersion _1.15”的文件,和对应的程序文件,将HONEYWELL 1900GHD条形码扫描枪用COM数据线链接到电脑,然后运行软件根据提示操作完成即可。

相关主题
文本预览
相关文档 最新文档