当前位置:文档之家› 艾默生SP系列驱动器中文说明书Unidrive SP_1

艾默生SP系列驱动器中文说明书Unidrive SP_1

艾默生SP系列驱动器中文说明书Unidrive SP_1
艾默生SP系列驱动器中文说明书Unidrive SP_1

艾默生DCS_OVATION系统手册

OVATION系统硬件培训手册 (Solaris操作系统) Rev.1 上海西屋控制系统有限公司 (Aug.2005)

OVATION系统 目录 Ovation 系统硬件 第一章 Ovation分散控制系统概述 1.1 系统概述 ……………………………………………………………1-1 1.2 典型的Ovation系统结构 ……………………………………………1-3 1.3 Ovation系统诊断 ……………………………………………………1-4 1.4 参考手册 ……………………………………………………………1-7 第二章 Ovation系统网络 2.1 系统的组成 ……………………………………………………………2-1 2.2 网络的结构形式 …………………………………………………... 2-1 2.3 单网网络星形拓扑结构………………………………………………….. 2-3 2.4 多网网络 …………………………………………………………... 2-4 2.5 网络设备的功能 ……………………………………………………2-4 2.5.1 快速以太网的一般概念 ………………………………….. 2-4 2.5.2 集线器(Hub) ……………………………………………2-5 2.5.3 交换机(Switch) …………………………………………... 2-5 2.6 Ovation网络地址 ……………………………………………………. 2-6 2.7 网络中的数据流 ……………………………………………………. 2-7 第三章 Ovation控制器 3.1 控制器 …………………………………………………………3-1 08/16/05 1

艾默生TD3200系列门机调试手册簿

量控制型门机专用变频器,适用于电梯门、各种自动门和其它需要往复运行控制的场合。 1.2 变频器型号说明: 1.3 变频器的铭牌: 1.4 TD3200系列变频器的主要型号: 变频器型号 额定输入电流(A)额定容量(kVA)额定输入电流(A)适配电机(kW)恒转矩负载 TD3200-2S0002D 2.65 0.5 1.3 0.2 TD3200-2S0004D 5.3 1.0 2.5 0.4 1.5 选配件: 1.5.1制动电阻 TD3200系列变频器含制动单元,如果有能耗制动的需求,请按下表选配制动电阻。 电压电机额定功率制动电阻规格制动单元使用率制动转矩最长连续使用时间 220V 0.2kW 200Ω/80W 20% 100% 30s 0.4kW 200Ω/80W 20% 100% 30s 1.5.2 操作面板: 操作面板型号为TDP-LED02,其实物见图一。

图一操作面板 1.5.3 操作面板安装座、操作面板电缆 操作面板安装座操作面板电缆是配套选用件。操作面板安装座型号为TDF-KB01。操作面板电缆有三种,型号为: TDC-CB0006A 0.6m; TDC-CB0015A 1.5m; TDC-CB0030A 3.0m。 1.6 变频器安装尺寸: 变频器型号适配电机(kW) 安装尺寸外形尺寸 安装孔径(mm)概重(kg) A(mm) B(mm) H(mm) W(mm) D(mm) TD3200-2S0002D 0.2 91 137 145 101 130 4 1.2 TD3200-2S0004D 0.4 二、变频器的调试与操作 2.1 操作方法 2.1.1 操作面板 操作面板示意图:操作面板的键盘,主要由LED数码管,LCD(液晶显示屏),按键三部分组成,其外形及功能区如图二所示:

艾默生监控模块

艾默生监控模块 PSM-E20监控模块功能: 电池管理 监控模块对电池的智能化管理主要体现在以下几种工作状态: 1、正常充电状态 监控单元自动记录均充和浮充的开始时刻,在上电(或复位)初始,如果监控单元发现均充过程尚未结束,则会继续进行均充。如果上电(或复位)前是处于限流均充状态,则继续进行限流均充;如果是处于恒压均充状态,则继续进行恒压均充。在限流均充时,当充电电压达到恒压均充电压值的时候,会自动转入恒压均充。 2、定时均充状态 用户可选择是否采用定时均充这种维护方式,还可对定时均充的时间间隔及每次均充的时间进行设定。一旦设定,电池管理程序就可自动计算电池定时均充的时间,以便确定在何时启动定时均充,何时停止定时均充,所有这些操作都是自动进行的,运行维护人员可在现场通过监控单元上的显示来明确这一过程,也可在远程监控中心的主机上查看这一过程。一般电池以每隔30天均充一次,每次均充24小时为宜,特殊情况必须根据电池说明书的实际的情况设置。 3、电池放电后均充状态 交流停电后,电池组对设备进行供电,放电终止后,再次恢复交流供电时,若电池电流大于设定值(转均充参考电流),则监控单元会自动控制模块进行均充。在监控模块的软件设置中,放电终止后的均充转换条件为:电池充电电流 4、其它电池管理功能 λ设置功能 电池的均浮充电压均可通过键盘设置,用户可根据不同型号的电池,不同的电池电压灵活配置,极大地方便了用户管理。均浮充电压设置好后,监控单元会根据当前的均浮充状态把电池端电压调节到设定的值。需要注意的是,若此时动力母排上有模块发生通讯中断,则模块进入自动保护运行模式,输出电压降为234V/117V,通讯正常后可自动退出保护运行模式。λ温度补偿 用户可选择是否对均浮充电压进行温度补偿,并可对温度补偿中心点、温度补偿系数进行设置。一旦设定,监控单元就会根据电池房的温度自动对浮充电压进行调节,确保电池工作温度正常。 λ容量分析 用户可设置电池的充电效率、放电特性曲线等参数来调整电池容量的计算结果。监控单元可根据电池电流、充放电状态以及充放电系数对电池容量进行估算,每隔15秒计算一次电池容量的变化量,并在菜单上实时显示出来,使用户能一目了然地看到电池容量的实时变化。λ自动与手动相结合 监控单元可在“自动”和“手动”两种方式下工作,在“自动”方式下,监控单元可自动完成上述的所有功能,完全不需人工干预;在“手动”方式下,电池的管理交给维护人员来完成,维护人员可通过菜单控制电池的均浮充转换,调节电压及模块限流点,还可以对模块作开关机控制,此时监控单元将只通过通讯采集各模块的数据及配电数据,不对模块作任何控制处理,因而不会在放电后作自动均浮充转换,也不会启动定时均充,但仍可对电池的容量进行估算。由于长期均充可能导致电池寿命下降,为了防止在“手动”方式下均充时间过长,监控单元会自动监视均充时间,当均充时间超过用户设定的定时均充时间时,就会转入浮充。

爱默生模块及监控中文说明书

PowerMaster智能高频开关电力操作电源系统 合作生产技术指导书 资料版本V5.0 归档日期2008-10-17 BOM 编码31031222 艾默生网络能源为客户提供全方位的技术支持,用户可与就近的艾默生网络能源办事处或客户服务中心联系,也可直接与公司总部联系。 艾默生网络能源 所有,保留一切权利。容如有改动,恕不另行通知。 艾默生网络能源 地址:市南山区科技工业园科发路一号 邮编:518057 公司网址:https://www.doczj.com/doc/612068458.html, 客户服务投诉热线:00 E-mail:https://www.doczj.com/doc/612068458.html,

第一章充电模块(必选件) 1.1 HD22010-3系列 1.1.1 模块简介 HD22010-3系列充电模块是电力电源最主要的配置模块,广泛应用于35kV到330kV的变电站电力电源中。 HD22010-3系列充电模块采用自冷和风冷相结合的散热方式,在轻载时自冷运行,符合电力系统的实际运行情况。 型号说明 HD 220 10 - 3 产品版本 额定输出电流10A 额定输出电压220Vdc 充电模块 产品系列 产品系列见下表。 表1-1 订货信息 工作原理概述 以HD22010-3模块的工作原理框图如下图所示。 图1-1 HD22010-3充电模块原理图 HD22010-3充电模块由三相无源PFC和DC/DC两个功率部分组成。在两功率部分之外还有辅助电源以及输入输出检测保护电路。 前级三相无源PFC电路由输入EMI和三相无源PFC组成,用以实现交流输入的整流滤波和输入电流的校正,使输入电路的功率因素大于0.94,以满足DL/T781-2001中三相谐波标准和GB/T 17794.2.2-2003中相关EMI、EMC标准。

艾默生SDC空调使用说明手册

艾默生SDC空调使用说明手册 一、设备用途 向地下吹风的打空调,用于机房温湿度调节。 二、接口类型 通讯接口采用RS485/232方式。 信息传输方式为异步方式,起始位1位,数据位8位,停止位1位,无校验。 数据传输速率为1200、2400、4800、9600和19200bps可以设置。 三、通信参数设置 1、控制器 SDC系列空调的控制器为PACC控制器,采用240*128点阵蓝色背光液晶显示 屏显示,用户界面操作简单。多级密码保护,能有效防止非法操作。控制器具 有掉电自恢复功能。通过菜单操作可以准确了解各主要部件运行时间。专家级 故障诊断系统,可以自动显示当前故障内容,方便维护人员进行设备维护。可 存储200多条历史事件记录,配置RS485接口,通信协议采用信息产业部标准 通信协议,控制器面包那如图1所示 图1 控制器面板 2、操作键功能说明 控制器有5个操作键,分别是开/关键、退出键、上移键、下移键和回车键。功 能见下表: 表1 操作键功能说明

3 3.1 主界面 图2 主界面 界面上包含三类机组工作图标,分别是动画运行状态图标、锁定状态图标和开关机主备状态图标,这些图标告知操作员机组正在何种运行模式下运行。图标及其含义如图3所示。 图3 图标含义 3.2 密码界面 在主界面下按回车键,显示输入密码界面,如图4所示。输入正确密码确认后即可进入主菜单界面。 图4 密码输入界面 进入菜单界面的密码分3个等级,需要密码打开的菜单在它的标题后标有菜单级别[1]、[2]、[3],以表示所需密码的级别。各种密码等级的使用者、初始密码、允许进入的菜单等级见图5。 图5 密码等级

艾默生说明书标准-3版

变频调速器(艾默生)使用说明 感谢您购买盾安空调,为使您更好的使用和维护机组,提高机组的运行效率,延长机 组的使用寿命,特请您注意以下几点: 1、请您保管好随机资料,在开启或检修机器前,仔细阅读说明书及随机资料。 2、安装工作及首次开机工作必须由受过训练的专业人员进行。 安装 按电控柜铭牌的编号将其与机组编号一一对应的互相匹配。注意:请一一对应匹配。 一、查收随机资料及附件 1、附件:①尼龙接头;②包塑金属软管;③导线若干等。 二、柜体安装 1、安装位置:控制柜安装机组旁边的墙壁上,如无墙壁,则用户自行做支架安装,建议安装位置 与机组风机段距离≤3米,高度(以操作界面为准):1.4~1.5米,接线出厂标配为3 米,若接线距离>3米,则接线部分由用户自行解决。 2、安装方式:明装。采用壁挂式安装,安装孔及尺寸见电控柜实体。 三、放线、接线、走线 1、柜式空调机组 电控柜固定完成后,按电机接线盒到电动机接线端子的弯曲距离放线。 2、按电气原理图、电气接线图、随机附件接好电源进线、接地线等导线。 3、若控制柜含BA干接点,则所需电缆用线由用户自备,建议使用线径0.75mm2导线。 调试 (0.7~5.5)kW变频器 一、数字操作器TOP-LED02各部说明: PRG:编程键; FUNC/DA TA:功能/数据键; >>:移位键; ∧:递增键; ∨:递减键; RUN:运行键; -1-艾默生变频调速器使用说明

STOP/RESET :停止/复位。 详细说明见随机变频器《使用手册》 二、变频器内部参数设置 注意:若变频柜含BA 干接点,将选择开关打到自动档,通过远程常开无源输入触点对变频器启停进行控制,然后检测运行状态输出、手/自动状态输出的信号输出是否正常;带可选项参数为增加远程调频功能时设置参数,由用户自行确定,接收和反馈信号均为DC0~10V 信号,出厂时不含此参数;出厂设置变频器跳码开关CN10跳为V 。 (7.5~55)kW 变频器 一、 数字操作器F1A452GZ1各部说明: MENU/ESC :编程/退出键; ENTER/DA TA :功能/数据键; PANEL/REMOTE :运行命令通道切换键; >>:移位键; ∧:递增键; -2- 艾默生变频调速器使用说明 序号 参数地址 参数含义 设置值 备注 1 F0.00 频率给定通道选择 0 LED 键盘显示单元调节(出厂设置) 4 主频率输入由0~10V 控制CCI (CN10跳线选择V 侧)(可选项) 2 F0.03 运行命令通道选择 1 运转指令由外部端子控制 3 F0.05 最大输出频率 50HZ 见电机铭牌额定频率 4 F0.06 基本运行频率 50HZ 见电机铭牌额定频率 5 F0.07 最大输出电压 380V 见电机铭牌额定电压 6 F0.10 第一加速时间设定 30S 如有需要,可适当延长 7 F0.11 第一减速时间设定 40S 如有需要,可适当延长 8 F0.12 输出频率上限设定 50HZ 9 F0.13 输出频率下限设定 30HZ 10 F3.00 防反转选择 1 禁止反转 11 F7.11 双向开路集电极输出端子Y2 16 风机故障信号(可选项) 12 F7.26 AO1端子输出范围选择 9 0~10V(可选项) 13 F7.29 模拟输出范围选择 00 0~10V 反馈输出(可选项) 14 F7.12 继电器输出功能选择 0 风机运行信号(可选项) 15 FH.00 电机极数 按电机铭牌 16 FH.01 额定功率 按电机铭牌 17 FH.02 额定电流 按电机铭牌

艾默生直流分路计量设备接入艾默生FSU安装调试指导手册知识讲解

艾默生直流分路计量设备安装指导手册 一、分路计量设备现场安装指导 1、常用安装工具及辅材准备 1)分路计量设备安装所需工具大致如图所示,施工小组上站之前注意要配齐这些工具,并注意工具绝缘保护。 2)工具:手电钻、螺丝刀、剥线钳、斜口钳、钳形万用表等。 3)辅材:导轨、自攻丝、压线端子、绕线管、机打标签纸等。 2、开关电源供电线路的区分与确认 霍尔传感器安装之前,必须确定出所有需要检测的线缆,并区分出各线缆归属的运营商。这一操作步骤一定认真完成,确保准确,如遇问题及时联系随工维护人员。 1)确认开关电源供电线路是否有电流 使用钳形万用表对每一条线缆进行测量确认,查看线缆中的电流大小,当电流大于0.5A时,默认用户使用,需要再次核实、校验。核实在用的线缆必须加装霍尔传感器进行监控(可多线缆安装一个霍尔传感器)。所有的一次下电、二次下电的供电线路都需要核实、校验并监控。 2)确认开关电源供电线路所属运营商 3、电量计量模块安装要求 1)电量计量模块安装位置选择 ①开关电源柜内,用导轨进行安装固定

②如果开关电源柜内无法安装,则安装在开关电源柜的两侧,如果开关电源柜两侧有其他机柜遮挡不方便安装,再选择电源柜的后侧。侧面安装位置应遵循从左往右,从上往下依次进行安装,为后续扩容留有位置。 2)固定导轨的安装 导轨安装时,选择距离电源柜顶部约4--5CM的位置,要保证电量计量模块安装后其最上端,不高于开关电源柜的顶部边缘。 3)电量计量模块的固定 ①电量计量模块固定在导轨上,注意保证卡槽固定到位、牢固。 ②电量计量模块所用线缆需用扎带绑扎、固定。 4、电量计量模块供电要求 电量计量模块采用-48V供电,供电位置必须选择在开关电源二次下电供电空开。供电线缆需用标签进行标注“电量计量模块用电”,且一定注意区分一、二次下电位置与所贴标签是否正确。

艾默生变频器操作说明

7#引风机带变频的停、送电操作须严格按照此步骤进行,否则会导致电气事故! 7#炉引风机变频器送电操作 1.检查旁路柜隔离开关位臵正确,各柜门封闭正常; 2.检查操作柱、变频器的急停按钮均复位,各柜门封闭正常; 3.合17G开关柜二次回路空开和保险,将断路器手车摇至工作位,并检查确认; 4.将17G开关柜转换开关切换至“远程”位; 5.送变频系统控制电源—自2#配电室Ⅱ-11 柜 7# 抽屉; 6.合变频器和旁路柜所有二次回路空开和保险; 7.检查变频器人机界面,主控系统开始自检,控制面板上2个指示灯同时点亮; 8.主控所有自检通过后,允许运行灯(绿色)闪烁; 9.点击人机界面上进入系统按钮,输入密码后可进行参数的设臵及监控; 10.将本地-远程选择开关拨至“本地”; 11.按下人机界面上预充电合闸按钮,变频器开始软启动,高压指示灯(红色)常亮; 12.待软启动结束,自动闭合进线高压断路器,合闸成功后,高压指示灯(红色)常亮; 13.将变频器“本地-远程”开关切换至“远程”位;(变频启停由操作柱和DCS实现); 7#炉引风机变频器停电操作说明 1.检查7#引风机已经停运,变频器确实处于停机状态; 2.按下17G开关柜“手分按钮”,分断6kV断路器,并摇至试验位; 3.断开17G开关柜二次回路空开和保险; 4.断变频系统控制电源—自2#配电室Ⅱ-11 柜 7# 抽屉; 注意: 1.电机运行时,打开变频器及旁路柜柜门,会连锁分断6kV断路器,导致停机; 2.电机运行时,断开旁路柜二次电源,会连锁分断6kV断路器,导致停机; 3.旁路柜的隔离开关只在倒闸时需要操作,正常运行期间不必频繁操作,否则会导致 接触不良;

艾默生充电模块定期维护指导说明

艾默生模块定期维护指导说明 一,维护时间间隔 对于只做了简单防尘网过滤的直通风系统,一般应用环境每半年清理一次;根据第一次维护清理的灰尘堆积情况,确定针对该站点的维护清理周期。对于在风沙较大的地区,或者比较繁忙的马路附近,公交枢纽或停车场附近的,积灰会比较严重,请适当缩短维护周期;反之对于室内型的,或者周围运行环境比较好的,则可以适当延长,但尽量不要超过一年。 二,维护清理所需工具 工具包括:十字螺丝刀,镊子,毛刷,控制模块的简易通信,万用表。 注意:选择十字口稍钝的十字螺丝刀或电批,防止打滑。 电气条件:三相380V交流,用于清理后测试模块。如果没有简易上电装置,可放在系统中每个模块逐一开机上电验证;注意必须单个模块验证合格后才能放入系统中运行。 三,ER45033/T模块的清理维护步骤如下: 1.取下模块上盖的固定螺钉,取下上盖,注意模块尾部有两个固定上盖的螺钉;注意取前 面板时底面的四个螺钉只需松开靠前端的两个,如图1所示。然后取下前面板的安装螺钉,并拔下显示板连接线缆的插头,如图2所示,再将前面板连同风扇一起取下。如果线缆插头点胶固定,请小心取下,防止将插头底座拔出。 图1 前面板和机箱底壳之间的固定螺钉示意图

图2 显示板与控制板之间的连接线缆 图3 风扇安装位置(注意风扇安装方向,切勿装反) 2. 用毛刷将散热器以及PCB板上的灰尘清扫干净,特别注意进风口处的器件,需要仔细清理。然后用风枪将残留在器件和PCB板上的灰尘吹掉,可以从出风口顺序往进风口方向吹扫(从出风口往进风口方向吹更容易将灰尘清理干净),直至将残留灰尘吹出机箱外。 3. 将拆下的面板风扇组件也清理干净。 (以下是ER45033/T清理后重新装配的步骤) 5. 现将风扇安装在面板上,将面板靠近机箱,插上显示板连接线缆,如图2所示;然后将面板组件安装到机箱上,装上侧面以及背面的安装螺钉。 6. 将电感板装上,注意电感板的安装螺钉要拧紧。确认接线缆两端是否都安装到位。

爱默生SKD变频器说明书

Getting Started Guide Commander SK AC variable speed drive for 3 phase induction motors from 0.25kW to 7.5kW, 0.33hp to 10hp Model sizes A, B, C and D Part Number: 0472-0000-07 Issue: 7 https://www.doczj.com/doc/612068458.html,

General Information The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or adjustment of the optional parameters of the equipment or from mismatching the variable speed drive with the motor. The contents of this guide are believed to be correct at the time of printing. In the interests of commitment to a policy of continuous development and improvement, the manufacturer reserves the right to change the specification of the product or its performance, or the content of the guide without notice. All rights reserved. No parts of this guide may be reproduced or transmitted in any form or by any means, electrical or mechanical including, photocopying, recording or by an information storage or retrieval system, without permission in writing from the publisher. Drive software version This product is supplied with the latest version of user-interface and machine control software. If this product is to be used in a new or existing system with other drives, there may be some differences between their software and the software in this product. These differences may cause the product to function differently. This may also apply to drives returned from the Control Techniques Service Centre. If there is any doubt, please contact your local Control Techniques Drive Centre or Distributor. Environmental Statement Control Techniques is committed to minimising the environmental impacts of its manufacturing operations and of its products throughout their life cycle. To this end, we operate an Environmental Management System (EMS) which is certified to the International Standard ISO 14001. Further information on the EMS, our Environment Policy and other relevant information is available on request, or can be found at https://www.doczj.com/doc/612068458.html,. The electronic variable speed drives manufactured by Control Techniques have the potential to save energy and (through increased machine/process efficiency) reduce raw material consumption and scrap throughout their long working lifetime. In typical applications, these positive environmental effects far outweigh the negative impacts of product manufacture and end-of-life disposal. Nevertheless, when the products eventually reach the end of their useful life, they must not be discarded but should instead be recycled by a specialist recycler of electronic equipment. Recyclers will find the products easy to dismantle into their major component parts for efficient recycling. Many parts snap together and can be separated without the use of tools, whilst other parts are secured with conventional fasteners. Virtually all parts of the product are suitable for recycling. Product packaging is of good quality and can be re-used. Large products are packed in wooden crates, while smaller products come in strong cardboard cartons which themselves have a high-recycled fibre content. If not re-used, these containers can be recycled. Polythene, used on the protective film and bags from wrapping product, can be recycled in the same way. Control Techniques' packaging strategy favours easily recyclable materials of low environmental impact, and regular reviews identify opportunities for improvement. When preparing to recycle or dispose of any product or packaging, please observe local legislation and best practice. Copyright ? June 2008 Control Techniques Ltd Issue:7 Software:01.08.00

艾默生开关电源用户手册31010887

PS48400-2C/50智能高频开关电源系统 用户手册 E1-20020314-C-1.0 艾默生网络能源有限公司

PS48400-2C/50智能高频开关电源系统 用户手册 资料版本E1-20020314-C-1.0 BOM编码31010887 艾默生网络能源有限公司为客户提供全方位的技术支持,客户可与就近 的艾默生网络能源有限公司办事处或客户服务中心联系,也可直接与公 司总部联系。 艾默生网络能源有限公司 地址:深圳市龙岗区坂雪岗工业区华为基地电气厂房一楼、三楼 邮编:518129 公司网址:https://www.doczj.com/doc/612068458.html,或https://www.doczj.com/doc/612068458.html, E-mail:info@https://www.doczj.com/doc/612068458.html,

版权声明 艾默生网络能源有限公司 版权所有,保留一切权利。 在没有得到本公司书面许可时,任何单位和个人不得擅自摘抄、复制本书(软件等)的一部分或全部,不得以任何形式(包括资料和出版物)进行传播。 版权所有,侵权必究。内容如有改动,恕不另行通知。 Copyright by Emerson Network Power Co.,Ltd. All rights reserved. The information in this document is subject to change without notice. No part of this document may in any form or by any means (electronic, mechanical, micro-copying, photocopying, recording or otherwise) be reproduced, stored in a retrieval system or transmitted without prior written permission from Emerson Network Power Co.,Ltd.

艾默生ES2402变频器调试指导书

ES2402变频器调试指导书 1、1、编码器连接(海德汉ECN1313) 2、操作器操作说明 面板操作说明 键盘包括:导航键、一个模式键M、三个控制键(含红色复位键) 四维导航键用于控制参数结构并更改参数值。 模式键用于切换各种显示模式,如察看参数,编辑参数、状态。 若选用键盘模式,可用三个控制键控制变频器。红色停止键可以用于变频器复位。

如果你第一次使用变频器时(单独变频器时,当变频器已安装柜内且到现场后,请不要随便按此操作), 变频器恢复出厂值方法: 方法是0.00=1233(欧洲标准),然后按红色复位键 改变控制模式方法: 将0.00=1253(欧洲标准),按红色复位键,然后 0.48从OPEN LP更改到SERVO。 按复位键(红色) 显示所有菜单方法: 0.49=L2,按M键,将0.00=1000,按红色复位键保存软件版本查询:20.01改变模式并恢复出厂值(菜单15到20除外):0.00=1255,按红色复位键 3、自学习步骤 一、自学习前准备工作: 1、使主机脱离负载。 2、通过短接线路的方法,使变频器输出接触器和抱闸打开,同步主机保证封星短接线已经断开, (如3、果满足检修条件,可以不用短接线路,直接按检修上行或下行信号控制器会输出变频器 输出接触器,方向及使能信号、抱闸信号) 4、设定参数0.48=SERO(闭环伺服)控制模式。 5、确定在变频器的扩展模块槽2上插入编码器分频卡(Universal Encoder Plus),

变频器的扩展模块槽见说明书。设定参数16.17=0 6、在连接编码器前最好检查一下参数3.36(变频器提供给编码器的电源电压),出厂缺省值3.36=5V。预防该参数修改后损坏编码器。 7、连接编码器,把编码器的接口连到变频器的15针编码器的输入口上(而不是PG卡的15针插口),并固定。 8、把参数调到3.02菜单(速度反馈),人为的正、反转动主机同时监控一下 菜单界面,是否有正、反速度反馈, 若没有的情况下请检修编码器的接线是否正确。 9、按下表依次输入参数,当采用ECN1313编码器时。

艾默生UPS用户操作指导书

UPS 用户操作指导书 一、显示面板说明: 图1-1 UPS 面板图 1:大屏幕液晶显示屏; 2:整流器工作指示灯; 3:蓄电池组工作指示灯; 4:旁路电源工作指示灯; 5:逆变器工作和输出指示灯; 6:负载在线指示灯; 7:整机报警蜂鸣器; 8:整机报警指示灯; 9:防紧急停机按钮误操作盖板; 10:紧急停机按钮; 11:逆变器启动按钮; 12:逆变器停机按钮; 13:故障清除按钮; 14:蜂鸣器消音按钮; 15:F1功能键; 16:F2功能键; 17:F3功能键; 18:F4功能键。

二、LED 指示说明: F1F2F3F4 逆变启动逆变停机 故障清除 消音告警 图 2-1 图2-1的LED 显示区的6个发光二极管(LED)作为运行状态和故障的指示灯, 绿色亮表示正常,红色亮表示故障。 【旁路灯】绿色亮表示旁路正供电;红色亮表示旁路输入超出保护范围;不亮 表示旁路正常但不供电。 【整流灯】绿色亮表示整流器正供电;绿色闪表示市电正常,整流器尚未供电; 红色亮表示整流器故障;不亮表示市电异常,无整流器故障。 【电池灯】绿色亮表示电池正供电;绿色闪表示电池放电终止预告警;红色亮 表示电池异常(包括电池过温、电池需更换、电池接触器未闭合); 不亮表示电池正常但不供电。 【逆变灯】绿色亮表示逆变器正供电;绿色闪表示逆变器工作但处于待供电状 态;红色亮表示逆变器故障;不亮表示逆变器未开启,且无故障。

【负载灯】绿色亮表示本机正常输出;红色亮表示本机因过载关机;不亮表示无输出;橙色亮(实际是红绿同亮)表示本机处于过载输出供电中。【告警灯】红色亮表示系统有告警发生;绿色亮表示无任何告警。 三、功能键说明: 图2-1所示的功能键控制区包括五个按钮: 【紧急关机键】紧急彻底关掉本机输出,并关掉整流模块、逆变模块、电池 输入。 【逆变启动键】逆变器具备启动条件时,按此键可启动逆变器工作;否则此 键按下无效。 【逆变停机键】当逆变器正在工作时,按此键可关闭逆变器。 【故障清除键】当系统故障或紧急关机导致UPS电源关闭后,如故障已经排除,按此键可重新启动系统工作。 【消音键】当有故障鸣叫时,按此键可消除本次鸣叫,再按此键可恢复故障鸣叫,当UPS处于故障消音状态时,新的故障可重新引发故障鸣叫。 以上任何按键按下都会有蜂鸣器短促的“嘀”声,当按键有效时,液晶显示屏的当前事件窗口均会增添一新的按键事件。 四、主要操作开关:

HD22010-3艾默生充电模块

2.1 HD22010-3系列 2.1.1 模块简介 HD22010-3系列充电模块是电力电源最主要的配置模块,广泛应用于35kV 到330kV的变电站电力电源中.本系列产品为HD22010-2系列充电模块的 优化产品,其各项性能指标优于HD22010-2充电模块. HD22010-3系列充电模块采用自冷和风冷相结合的散热方式,在轻载时自冷 运行,符合电力系统的实际运行情况.模块外形尺寸与HD22005-3充电模块 相同,因此模块的功率密度有所增高. 型号说明 HD 220 10 - 3 产品版本 10A额定输出电流 220Vdc额定输出电压 充电模块 订货信息 订货信息见下表. 表2-1-1 订货信息 名称型号编码单位定购指南备注 充电模块HD22010-3 02130517 PCS根据系统要求配置个数自然冷/风冷结合防尘设计 充电模块HD11020-3 02130XXX PCS根据系统要求配置个数自然冷/风冷结合防尘设计 工作原理概述 下面以HD22010-3模块为例介绍产品,工作原理框图如下图所示. 三相 交流输入 直流 176V~286V 0~2860W 输入 EMI 三相 无源PFC DC/DC 整流 滤波 输出 EMI 输入检测 保护 辅助 电源 DC/DC 控制与保护 输出,温

度检测 模块 监控 RS485 图2-1-1 HD22010-3充电模块原理图 HD22010-3充电模块由三相无源PFC和DC/DC两个功率部分组成.在两功率部分之外还有辅助电源以及输入输出检测保护电路. 前级三相无源PFC电路由输入EMI和无源PFC组成,用以实现交流输入的整流滤波和输入电流的校正,使输入电路的功率因素大于0.92,以满足 DL/T781-2001中三相谐波标准和GB/T 17794.2.2-2003中相关EMI,EMC 标准. 后级的DC/DC电路由DC/DC变换器及其控制电路,整流滤波,输出EMI 等部分组成,用以实现将前级整流电压转换成电力操作系统要求的稳定的直流电压输出. 辅助电源在输入无源PFC之后,DC/DC变换器之前,利用三相无源PFC的直流输出,产生控制电路所需的各路电源. 输入检测电路实现输入过欠压,缺相等检测.DC/DC的检测保护电路包括 输出电压电流的检测,散热器温度的检测等,所有这些信号用以DC/DC的 控制和保护. 结构及接口 1.模块外观 HD22010-3充电模块的外观如下图所示. 图2-1-2 HD22010-3充电模块外观 2.前面板 HD22010-3充电模块前面板如下图所示. 紧固螺钉 LED显示面板 指示灯 显示切换 按钮 拉手盖板 风扇罩及 防尘网 拨码开关 手动调压 按钮 图2-1-3 充电模块前面板 1)LED显示面板 显示模块的电压,电流或告警信息. 由显示切换按钮进行输出电压和电流的显示切换.显示3位数字,电压显示精度为±0.3V,电流显示精度为±0.2A. 出现模块告警时,闪烁显示故障代码. 2)指示灯 模块面板上有3个指示灯,功能见下表.

艾默生E变频器调试指导书完整版

艾默生E变频器调试指 导书 HEN system office room 【HEN16H-HENS2AHENS8Q8-HENH1688】

E S2402变频器调试指导书 1、1、编码器连接(海德汉ECN1313) 2、操作器操作说明 面板操作说明 键盘包括:导航键、一个模式键M、三个控制键(含红色复位键) 四维导航键用于控制参数结构并更改参数值。 模式键用于切换各种显示模式,如察看参数,编辑参数、状态。 若选用键盘模式,可用三个控制键控制变频器。红色停止键可以用于变频器复位。 如果你第一次使用变频器时(单独变频器时,当变频器已安装柜内且到现场后,请不要随便按此操作), 变频器恢复出厂值方法: 方法是=1233(欧洲标准),然后按红色复位键 改变控制模式方法: 将=1253(欧洲标准),按红色复位键,然后?从OPEN LP更改到SERVO。 按复位键(红色) 显示所有菜单方法: =L2,按M键,将=1000,按红色复位键保存软件版本查询: 改变模式并恢复出厂值(菜单15到20除外):=1255,按红色复位键 3、自学习步骤 一、自学习前准备工作: 1、使主机脱离负载。 2、通过短接线路的方法,使变频器输出接触器和抱闸打开,同步主机保证封星短接线已经断开, (如3、果满足检修条件,可以不用短接线路,直接按检修上行或下行信号控制器会输出变频器 输出接触?器,方向及使能信号、抱闸信号) 4、设定参数=SERO(闭环伺服)控制模式。 5、确定在变频器的扩展模块槽2上插入编码器分频卡(Universal Encoder??Plus), 变频器的扩展模块槽见说明书。设定参数=0 6、在连接编码器前最好检查一下参数(变频器提供给编码器的电源电压), 出厂缺省值=5V。预防该参数修改后损坏编码器。 7、连接编码器,把编码器的接口连到变频器的15针编码器的输入口上(而不是PG 卡的15针插口),并固定。 8、把参数调到菜单(速度反馈),人为的正、反转动主机同时监控一下菜单界面, 是否有正、反速度反馈, 若没有的情况下请检修编码器的接线是否正确。

基站开关电源二次下电配置指导书(艾默生PAM-X和中兴ZXDU68监控模块标准规定样式)

基站开关电源柜一、二次下电配置指导书 一、基站供电系统结构概述 基站供电系统主要由交流供电系统和直流供电系统组成。 交流供电系统运行方式: (1)市电正常时,由市电供电; (2)市电停电后,移动油机未到站时,站内通信设备由蓄电池放电供电; (3)移动油机到站,待油机启动后,由油机供电; (4)市电恢复后,由市电供电。 直流供电系统的运行方式: 在线恒压充电的全浮充供电方式。 (1)当交流电源正常时,由整流器和蓄电池并联浮充供电(整流器一方面给通信设备,一方面又给蓄电池充电,以补充蓄电池因自放电而失去的电量); (2)当交流电源中断后,由蓄电池单独向通信设备供电;

(3)当交流电源恢复供电时,开关电源的监控模块自动启动整流器向通信负荷供电,并对蓄电池进行充电。 蓄电池组既为备用电源,又可以吸收高频纹波电流。 二、开关电源柜硬件配置概述 当前基站中常见的电源柜厂家有艾默生、中兴、中达、华为、北京动力源等,其中艾默生的占比最大,以下以艾默生电源柜做示例。 1、开关电源柜功能架构 (1)逻辑架构 高频开关组合电源由交流配电单元、直流配电单元、整流模块、监控模块组成。 交流配电单元:输入市电或油机电源,将交流电能分配给开关电源整流模块使用;

含有浪涌保护器,作为基站电源系统的第二级防雷保护。 直流配电单元:通过直流汇流母排,将开关电源整流模块输出的直流电能提供给通信设备用电,并对电池进行充电。 整流模块:从交流配电取得交流电能,将交流电整流成直流电,输出到直流母排。监控模块:实时监测和控制电源系统各部分工作,对电池进行自动管理,具有标准的RS232或RS485通信口,作为后台监控的接口。 (2)开关电源柜现场图 2、交流配电单元

艾默生EV2000变频器故障代码

艾默生EV2000变频器故障E006 E004 故障代码故障类型故障代码故障类型 POFF 输入欠压 E008 输入缺相 E001 加速过流 E009 输出缺相 E002 减速过流 E010 模块保护 E003 恒速过流 E011 逆变过热 E004 加速过压 E012 整流过热 E005 减速过压 E016 读写故障 E006 恒速过压 E018 接触器未吸合 E007 控制电源过压 E019 电流检测电路故障 1、电流检测故障(如报E019,E001): (1)控制板Q1()坏。 (2)7840坏:在变频器通电时,用直流档,黑接5脚,红分别接6,7,8脚,值为,,5为正常,否则7840坏。 (3)小板坏:在变频器通电时,用直流档,黑接7840的5脚,红分别接小板的脚从左到右应为,,,,0,。 如值不对,小板坏:此时可更换小板坏中的三个小IC( LMV393),如还不好,更换小板。 2、显示POFF: 驱动板上电POFF,测CVD电压正常应为-,如测得,可能R51,R52,C36,C37,排线中的某一个坏, 其中的电解电容坏的最多。只在带电机运行时报POFF,驱动板变压器也有可能坏。 3、缓冲电阻坏: 缓冲电阻和滤波大电容是成对的。如果其一坏,另一个很可能也坏。缓冲电阻坏也有可能是

继电器不吸合(继电器坏或控制板坏,或与二者相连的电路上元件坏)引起。单相输入(220V)的变频器, 特别要注意:如果无显示或炸机,很可能是用户接入了三相电(380V)引起的(可察控制板的故障记录:母线电压是否由310变为了540)。此时不断IPM的整流桥已坏,滤波大电容也坏(或炸裂或顶面凸起变硬)。如果只更换IPM后就上电,会听到“啪,啪”的响声(电容内的声音),应立即掉电,否则IPM的整流桥又会坏。发现一个大电容坏,最好都换新的。因电容是易坏易老化的器件。 4、显示不稳: 先有显示,然后没有,风扇停下,电压只有12,此种现象一般是U1厚膜坏。报故障E015:通电指示灯亮,键盘不亮,拨了风扇就好--风扇短路 5、不制动: 01180099,01180100,01180113,01180114 的制动管不在IPM内部,变频器炸机和不显示很可能就是在变频器停机制动时引起的,所以更换IPM后,一定要检测制动电路的好坏:制动光耦,制动管(MOS管不好测,可测其串联的续流二极管,正常应为左右),门极电阻(也就是MOS管的门极电阻,正常应为100欧姆)。修好上电后,TD900 F093改为150,报E007,红接P(+),黑接PB,如电压在17-30跳动,制动正常。TD3200 F133=150 直流电压 270-350V 制动起作用。 6、炸整流桥: 如果测得部分整流桥损坏,而逆变桥全是好的,就有可能是正负母排之间打火引起。环境潮湿是主因,一般是有水滴在正负接线端子之间,或者是有水滴在正接线端子和散热器之间引起炸机的。此种坏机的接线端子绝缘性已变差,一定要更换,否则一上电又炸了。另一种原因就是滤波大电容短路(或炸裂或顶面凸起变硬),也要注意更换电容。 7、机器打嗝: 即风扇时快时慢,无显示。一般是控制板短路了,去掉控制板再上电,如还打嗝,有可能就是厚膜周边的器件坏了,例如TD1000大体积R56电阻27欧的阻值变大了很多,即打嗝保护电路自身坏了。开关电源不工作,可量其中一个电阻的电压,如有点电压且在跳变,说明开关电源已起振,但后面电路短路了(变压器脚间连锡,滤波电容碰歪),打嗝保护电路在起作用。如一点电压也没有,说明开关电源没起振,一般是厚膜坏或2844及附近器件坏。 8、风扇无力,转速慢:

相关主题
文本预览