Mannal

Functions

1.GSM & PSTN double nets design to make the reliability of alarm information transmission.

2.Host working status can be set by GSM wireless network or PSTN cable networks.

3.Host site monitoring and full-duplex intercom.

4.16 wireless zone, and 5 wire zone can be set to outdoor alarm, indoor alarm, play 24 hours alarm, silent alarm ,sound alarm, fit to different situations.

5. wire zone can be set open or closed alarm freely to fit any kinds of wire detector.

6.with external sirens interface.

7. Host can easy learn to wireless detector code.

8.Set the host alarm or disalarm by call in or send SMS form other area.

9.Host can be stored 5 groups of SMS user number.

10.host can be stored 5 groups of telephone number.

11.Host can be stored 1 groups of SMS center number and 1 groups of phone center number

12.AC power lost will send the SMS to the user.

13.When the alarm happen, the relay inside will control the power, video recorder, etc.

14. GSM 850/900/1800/1900 band supply

15. Built-in batteries, auto-charger.

Configuration of the base

10-Pin ports: GND; SIREN; RELAY1; RELAY2; SPEAKER; I5; I4; I3; I2; I1

The first port—Ground line; The second port—siren, The third and fourth port—Relay, he fifth port---Siren output, The fifth to tenth ports all line input.

SIM Card—under the box,,open the cover and inset SIM card.

RESET Key-- The alarm system will come back to the original statement when keeping pressing the RESET and connecting the power supply at the same time. The original password is 123456. At this moment, all coded information has been deleted

Power--- input 12DC/1.5A power

Switch---on or off power

Antenna---You should connect antenna before insert the power supply.

SIGNAL lamp flash green show in touch with GSM network.

STA TUS lamp show red in 20 second when the base is power on. if every thing is ok, STA TUS lamp show slow flash green (in outdoor alarm situation)or show fast flash green (in indoor alarm situation) , STA TUS lamp show still green (not in alarm situation).if alarm happened, STA TUS lamp show flash red and start dial out and sent SMS.

Set call out phone number and send SMS number when alarmming

1.you can send the message to the base to program the 5 group alarm phone number and the 5 group

alarm SMS number.The format:password #operation code # content #

123456#10# 139********#. save first group alarm SMS number into the base.

123456#11# 139********#. save second group alarm SMS number into the base.

123456#12# 139********#. save third group alarm SMS number into the base.

123456#13# 139********#. save fourth group alarm SMS number into the base.

123456#14# 139********#. save fifth group alarm SMS number into the base.

123456#15# 139********#. save first group alarm Phone number into the base.

123456#16# 139********#. save second group alarm Phone number into the base.

123456#17# 139********#. save third group alarm Phone number into the base.

123456#18# 139********#. save fourth group alarm Phone number into the base.

123456#19# 139********#. save fifth group alarm Phone number into the base.

2. Program SMS monitoring center:

123456#40# 139********#0# ,mean the monitoring center will receive SMS when alamming.

123456#40# 139********#1# ,mean the monitoring center will receive SMS when alamming ,and when you are making the base in alarm or disalarm staute, the monitoring center will also receive SMS 3.Program PSTN monitoring center:

You also can program: phone number # room No. #0#, it will dial the room number when alarming.(for the users whose alarm system is working with monitoring center)

123456# 41# 88886666 # 0001 #0# , show monitoring center:88886666; room No.0001

123456# 41# 88886666 # 0001 #1# , mean the monitoring center will receive call when alam.and when you are making the base in alarm or disalarm status, the monitoring center will also receive SMS.

4. Program disalarm or alarm status monitoring center:

123456# 42#88880000#,this means the base will dial 88880000 to inform you when you make the base change to alarm status,the status LED from still green change into flashing green .

123456# 43#88881111#,this means the base will dial 88881111 to inform you when you make the base change to disalarm status,the status LED from flashing green change into still green.

How to test host alarm function

The base are in disarm status when power on. you can make the base arm by controller (arm key) or

send SMS (123456 # 1 # 1).

When the base in arm status, LED flash green, if line input trigger alarm (I1 I2 I3 I4, I5, connect to ground or open) or wireless alarm (wireless infrared detector trigger, wireless remote control , wireless magnetic door, etc), emergency button, or call in to make arm( 123456 # 2# 1),the base will arm and send warning message.

1 if the base has programed SMS users, it can sent SMS out according to trigger (line I1 I4, I2, I3, I5, wireless detector, 1-16).

2 if the base has programed users phone,it can call out each users telephone. you can hear siren voice.

3 when alarming, you can monitor live site and remote control without inter password, you can inter 2 # 1 set base immediately sound, 2 # 0 # closed sound.

4 when alarming, you can monitor live site and remote control without inter password, you can inter 3 # 1 to monitor live site ,3 # 0# close monitoring.

5 when alarming, you can talk with person, without inter password, can inter 4 # 1 to talk, inter 4 # 0 to closed.

6 when alarmming,you aswer it, if it is wrong call, you can inter 1 # 1 to set base in arm status, and the hase will not call next telephone again.

7 when alarming, you can disarm by controller.

8 In the normal use with built-in batteries, when the external power source lost and return, the base will send messages to users.

9 Mormally, you can controll the base by call in, and enter the password to further operation.

----------------------------------------------------------------------------------------

How to send SMS or calling in to set the base

you call in, type password 123456 #, you will hear a beep shows you can inter function operation :to make siren ,inter 2#1#

1.In the above SMS operation, you will receive a answer message for confirmation after you send the

message command to the base,thus you will know the working state of the base.(arm, disarm or alarm),if the answer is the present state of the base,you may send wrong seessage to the base.

2.You also can only send the password to check out the present state of the base. The replied message as

follows:

Disarm,SMS-ON,Phone-ON,Siren-ON,monitor center -OFF, arm phone- OFF, Disarm phone-OFF Operation instructions order:

Note:upon (1- 6)Row,can be set by keyboard or SMS,ther otheris only by SMS.

In the above phone operation, one long beep shows successful, two short beeps shows failed, you should try again.

When you inter wrong word, you need inter * to clear it and retry again.

Setup fixtime arm or disarm:

123456#31# ,make time fit with GSM base station

123456#31#2200#0800#

Show: start arm: 22:00;end arm:08:00

Set wireless aera:

123456#50#1#Room#,Show: 50—wireless aera0,1--arm;name of aera 0 is Room.

(Paremeter,0—disarm;1—arm;2-24H arm)

Set wire aera:

123456#66#1#front door#0#,Show:

66—wire aera(I1),1--arm;name of aera (I1) is front door;0-open trigger

(Paremeter,0—disarm;1—arm;2-24H arm) (Paremeter, 0-open trigger;1-short trigger)

Host can fit 15 wireless detector, show message wireless alarm messages (1) to wireless alarm (15). The host also fit 5 line input, show message, wire alarm (1) to play wire alarm (5), you can change the message by send SMS

Note: the message does not exceed 12 Chinese or English 24 letters

how to add new detector in the base

If the baset need to add the wireless infrared detector, wireless magnetic door, wireless remote etc. :

1)indoor detector : press the RESET button (RESET) for 2 seconds till LED turn red, you set detectors

emit signal, the base LED is flash. Show the detector inter the base. It will automatic close in 20 seconds if no detectors emit signal .

2)outdoor detector : press the RESET button (RESET) for 2 seconds till LED turn red,press the RESET

button again ,LED turned orange, let these detectors emit signal, the base LED is flash. Show the detector inter the base. It will automatic close in 20 seconds if no detectors emit signal .

3)If the base has three wireless detector inside, show wireless defenee zone 1-3, if you add a new detector,

this detector will be zone 4.

Note: outdoor detector and indoor detector will in arm status when you set outdoor arm with controller.only indoor detector will in arm status when you set indoor arm with controller. According to the home protection remote, only home protection probe in protection status.

How to delete the lost detectors

If you need to move out detector in the base(the wireless infrared detector, wireless magnetic door, wireless remote etc.) :

1)Sent SMS to the base,123456# (50—65)# * *,to delete the detector, the aera is empty.

The new detector will be saved in this aera if you add detector.

2) RESET: press RESET (behind the base RESET) ,then open the power, wait 3 seconds ,LED lights and external loudspeakers sound, the baset RESET ok. The base remove all wireless detector, password recovery: 123456, all Settings recovery in factory Settings. Reset does not affect the message content in the base. The original wireless detector, must redo according to above the operating methods, the first study in the host will be 1, the maximum is zone 16.

How to use controllor

Wireless remote controllor has four key: Disarm key,Outdoor arm key ,Indoor arm key,emergency button. When you press Outdoor arm key, LED orange flashing for 10 seconds waiting for you go out, LED change green flashing show arm start. If wire and wireless detector is trigger (all detector effective), the base will call out and send SMS, LED become red lights flashing status.

When you press Indoor arm key, LED orange flashing for 10 seconds waiting for you go out, LED change green flashing show arm start. If wire and wireless detector is trigger (only indoor arm detector effective, outdoor detector ineffective), the base will call out and send SMS, LED become red lights flashing status. When you press disarm, LED green light ,all the detectors trigger do not alarm.

When you press the emergency button, no matter the base in arm status (LED flash light green ) or disarm status (LED light green ) ,the base will immediately alarm, call out and send SMS, they become red lights flashing status.

Recording Settings

you can record your geographic location, family address voice message into base, it will sound out when arm. Recording operation:

long press recording keys behind the host after 2 seconds until the Record lights go on, the base built-in microphone inside, you can speek 10 seconds voice message,it will record in the base, when 10 seconds pass, the record light went out, automatic end Record. If need to change the voice message, repeat the operation.

main technical parameters

1, standby current: 20mA

2, the power supply voltage: 9V - 12 v

3, working temperature: - 10 - 55 c

4 ,support GSM850/900/1800/1900MHz

5 ,receiving code: ASK

6 ,receive frequency: 315/433 /868/915MHz

7 ,remote distance of 100 m (open) :

8, 16 wireless zone

相关主题