Poultry Fish Meat Cosmetics Pharmaceutical Process Support Waste S a n i f l o ? S O L U T I O N S Fruits &Vegetables Beverages Sauces W ilden is a global leader in sanitary and bio-pharmaceutical pumps and offers a wide range of solutions for various food, beverage, dairy, personal care and bio-pharmaceutical applications. Wilden’s Saniflo? and BioPharm? pumps have been engineered to meet the highest standards and requirements in the industry including: EHEDG, 3A, CE, ATEX, USP Class VI, and FDA CFR 21.177. Wilden’s premiere sanitary and bio-pharmaceutical pumps have the versatility you require, safety you need and the capability of efficiently pumping a wide range of viscosities, solids and shear sensitive products. Wilden’s Saniflo? and BioPharm? pumps are offered with passivated stainless steel components, available in multiple sizes and with various surface finishes. As the global leader in AODD pumps we are committed to your industry. Wilden understands that safety, performance, hygienic requirements and the careful transfer of your products are essential when choosing process equipment. Air operated pumps (non electrical) Superior product containment Bolted & Clamped liquid paths Self priming No damage when run dry Deadhead without damage Variable flow & pressure High viscosity Intrinsically safe by design Lube-free operation Shear sensitive Large solids passage Low water requirements Low product degradation Ease of operation and maintenance Sauces, Purees & Beverages Poultry, Fish & Meat process Fruits, Vegetables & Condiments Pharmaceutical products Health & Personal care products Chromatography, Separation, Purification High Purity product transfer Filter press feed pumps Acids, Solvents, Caustics & Alcohols Abrasive media & Solids Chemical injections & Metering Waste water transfer CIP , SIP , COP SANIFLO? & BIOPHARM? SOLUTIONS WILDEN , the Evolution of Clean Dairy Prepared Foods Confectionary Bio-Pharmaceutical FDA USP class VI UNIQUE CHARACTERISTICS DIFFICULT APPLICATIONS

气动隔膜泵使用说明

气动隔膜泵是一种由于隔膜往复变形而引起容积变化的容积泵。它的工作原理类似于柱塞泵。由于隔膜泵工作原理的特点,隔膜泵具有以下特点:(1)泵不会过热:以压缩空气为动力,排气时是膨胀吸热的过程;气动泵工作时,温度降低,无有害气体排放(2)不会产生电火花:气动隔膜泵不需要电源,接地后可防止静电火花;(3)它可以通过含颗粒的液体:由于体积式工作且入口为球阀,不易堵塞;(4)物料的剪切力极低:工作时如何吸入和吐出,因此物料的搅动最小,适用于不稳定物料的输送(5)流量可以通过在物料出口处增加节流阀来调节流量来进行调节;(六)具有自吸功能;(7)它可以无危险地运行;(八)可以潜水;(9)可以输送各种流体,从低粘度到高粘度,0.2可以从腐蚀性中获得粘性;(10)没有复杂的控制系统电缆,保险丝等;(11)体积小,重量轻,移动方便;(12)无润滑,易于维护,不会因滴落而污染工作环境;(13)泵始终可以保持高效率,不会因磨损而降低;(14)能源利用率为100%,关闭出口时,泵将自动停止,设备将移动,磨损,过载和发热; (15)它不会动密封,易于维护,避免泄漏。工作无死角

气动隔膜泵的使用注意事项 确保流体中包含的最大颗粒数不超过泵的最大安全通过粒径标准; 入口压力不应超过泵的最大允许工作压力。高于额定压力的压缩空气可能导致人身伤害,财产损失和泵性能损坏; 确保泵压管道系统能承受最大输出压力,并确保驱动气系统清洁,正常的工作状态; 静电火花可能会引起爆炸,从而导致人身伤害和财产损失。根据需要,使用足够大的截面积的导线将泵上的接地螺钉正确可靠地接地; 接地要求符合当地法律法规要求和现场的一些特殊要求; 紧固泵和所有连接管接头,以防止由于振动冲击而产生静电火花。使用防静电软管; 为了定期检查和测试接地系统的可靠性,接地电阻应小于100欧姆。 保持良好的排气和通风,远离易燃,易爆和热源; 泵的排气中可能含有固体。不要将排气口对准工作区域或人员,以免造成人身伤害; 当隔膜损坏时,材料将从排气消声器中弹出;

化学品溶液移送和气动隔膜泵安全操作规程(通用版)

( 操作规程 ) 单位:_________________________ 姓名:_________________________ 日期:_________________________ 精品文档 / Word文档 / 文字可改 化学品溶液移送和气动隔膜泵安全操作规程(通用版) Safety operating procedures refer to documents describing all aspects of work steps and operating procedures that comply with production safety laws and regulations.

化学品溶液移送和气动隔膜泵安全操作规 程(通用版) 1、操作人员必须经过上岗培训,严格遵守操作规程和HSE提示卡。 2、戴化学安全防护眼镜、佩戴防酸碱口罩、穿耐酸碱橡胶胶靴、穿工作服、戴耐酸碱橡胶手套。 3、装卸前应妥善准备好应急用水,做好安全防范措施,保障安全工作。 4、化学品溶液移送必须二人协同作业,一人在室外负责溶液与移送泵对应接口的连接,另一个负责移送泵控制。 5、室外人员首先要检查输液管、罐车、泵各阀门是否安全、正常、有效。阀门连接后要再次检查溶液与移送管的是否连接正确,确认后方可打开连接阀门,通知室内负责移送泵人员,开启移送泵。

6、室内负责移送泵人员,在工作前要检查和调整进气压力,不要超过泵的最高允许使用压力0.3Mpa,阀门开启后,要观察移送泵的工作情况,发现异常,立即停机。 7、化学品溶液移送过程中,工作人员不得离开现场,密切注意溶液罐容量情况,溶液移送后关闭好相关阀门及上锁。 8、各操作人员应严格遵守以上各操作规程,安全管理制度,严格遵守危险化学品有关法律、法规。保障生产安全、人生安全、设备安全,保障生产正常进行。 9、若发生硫酸、盐酸等危化品被盗、丢失等情况应及时向车间负责人,行政部和公司主要领导汇报。 10、严禁私自灌装和使用硫酸,严禁私自拥有或送与他人具有强腐蚀性的危化品,违反者按国家危化品管理规定追究责任。 行政部辅助生产车间 2012年修订 云博创意设计 MzYunBo Creative Design Co., Ltd.

QBY1气动隔膜泵性能参数表

QBY1气动隔膜泵性能参数表 型号最大流量 (L/min) 出口压力 (Bar) 吸程 (m) 口径 (mm) 最大允许颗粒直径 (mm) 最大空气消耗量 (L/min ) QBY1-10 16 6.9 5 10 1 300 QBY1-15 20 6.9 5 15 1 300 QBY1-25 100 6.9 5 25 2.5 600 QBY1-40 140 6.9 5 40 4.5 600 QBY1-50 240 6.9 5 50 8 900 QBY1-65 280 6.9 5 65 8 900 QBY1-80 400 6.9 5 80 10 1500 QBY1-100 480 6.9 5 100 10 1500 QBY1气动隔膜泵既能抽送流动的液体,又能输送一些不易流动的介质,具有自吸泵、潜水泵、屏蔽泵、泥浆泵和杂质泵等输送机械的许多优点。 1、不需灌引水.吸程高达5m.扬程达70m.出口压力≥6bar。 2、流动宽敞,通过性能好.允许通过最大颗粒直径达10mm。抽送泥浆、杂质日寸,对泵磨损甚微; 3、扬程、流量可通过气阀开度实现无级调节(气压调节在1—7 bar之间): 4、该泵无旋转部件,没有轴封,隔膜j|等抽送的介质与泵的运动部件、工件介质完全隔开,所输送的介质不会向外泄漏。所以抽送有毒、易发挥或腐蚀性介质时,不会造成环境污染和危害人身安全; 5、不必用电.在易燃、易爆场所使用安全可靠; 6、可以浸没在介质中工作: 7、使用方便、工作可靠、开停只需简单地打开和关闭气体阀门.即使由于意外情况而长时间无介质运行或突然停机泵也不会因此而损坏.一旦超负荷,泵会自地动停机,具有自我保护性能,当负荷恢复正常后,又能自动启动运行; 8、结构简单、易损件少,该泵结构简单,安装、维修方便,泵输送的介质不会接触到配气阀,联杆等运动部件,不象其他类型的泵因转子、活塞、齿轮、叶片等部件的磨损而使性能逐步下降: 9、可输送较粘的液体(粘度在1万厘泊以下): 1 0、本泵无须用油润滑,即使空转.对泵也无任何影响,这是该泵最大特点。 优势 采用压缩空气为动力源,对于各种腐蚀性液体,带颗粒的液体,高粘度、易挥发、易燃、剧毒的液体,均能予以抽光吸尽,尤以适合易燃易爆场。

气动隔膜泵操作规程

气动隔膜泵操作规程 气动隔膜泵操作规程 1、气动隔膜泵输送的物料其温度应<100℃,以保护膜片的正常使用。 2、气动隔膜泵开车前经系统检查都完好后,再使用泵头内充满被输送的料液,以使料液能自流进泵。 3、接通电源,再使变速机的拖动电机启动,然后调节转差离合器控制装置微调旋钮,使曲轴转动。 4、取下控制阀上盖,用手按动补油阀芯上端多次,排除液压腔内空气,直至没有气泡出现为止,此时即为液压油充满液压腔,即可开始正常工作。 5、气动隔膜泵使用时控制阀压力最好与喷嘴压力一致,不要形成膜片前有过大的压力差。 6、气动隔膜泵在使用中应经常检查进料泵温度、出泵料液压力、泵的运行情况。 7、气动隔膜泵停车时先将转差离合器控制装置调旋到‘0’位,曲轴停止转动。 8、气动隔膜泵如停用时间过长,则需对泵头部分剩余料液排除,以防球阀将进出料口堵住、锈蚀。 9、气动隔膜泵一般使用40#机油,换油时应将原有油清洗干净。 10、经常保持气动隔膜泵的清洁性,及电机良好的绝缘性,及时做好运行、停运、事故、维修等记录。QBK气动隔膜泵是第三代气动双隔膜泵,具有使用寿命长,不会停顿等优点,它既能抽送流动的液体,又能输送一些不易流动的介质,具有自吸泵、潜水泵、屏蔽泵、泥浆泵和杂质泵等输送机械的许多优点。 1、不需灌引水.吸程高达5m.扬程达70m.出口压力≥6kg/cm2。 2、流动宽敞,通过性能好.允许通过最大颗粒直径达10mm。抽送泥浆、杂质时,对泵磨损甚微; 3、扬程、流量可通过气阀开度实现无级调节(气压调节在1—7kg/cm2之间): 4、该泵无旋转部件,没有轴封,隔膜等抽送的介质与泵的运动部件、工件介质完全隔开,所输送的介质不会向外泄漏。所以抽送有毒、易发挥或腐蚀性介质时,不会造成环境污染和危害人身安全; 5、不必用电.在易燃、易爆场所使用安全可靠; 6、可以浸没在介质中工作: 7、使用方便、工作可靠、开停只需简单地打开和关闭气体阀门.即使由于意外情况而长时间无介质运行或突然停机泵也不会因此而损坏.一旦超负荷,泵会自地动停机,具有自我保护性能,当负荷恢复正常后,又能自动启动运行; 8、结构简单、易损件少,该泵结构简单,安装、维修方便,泵输送的介质不会接触到配气阀,联杆等运动部件,不象其他类型的泵因转子、活塞、齿轮、叶片等部件的磨损而使性能逐步下降: QBK气动隔膜泵既能抽送流动的液体,又能输送一些不易流动的介质,具有自吸泵、潜水泵、屏蔽泵、泥浆泵和杂质泵等输送机械的许多优点。 1、不需灌引水.吸程高达5m.扬程达70m.出口压力≥6bar。 2、流动宽敞,通过性能好.允许通过最大颗粒直径达10mm。抽送泥浆、杂质时,对泵磨损甚微; 3、扬程、流量可通过气阀开度实现无级调节(气压调节在1—7 bar之间): 4、该泵无旋转部件,没有轴封,隔膜泵|等抽送的介质与泵的运动部件、工件介质完全隔开,所输送的介质不会向外泄漏。所以抽送有毒、易发挥或腐蚀性介质时,不会造成环境污染和危害人身安全; 5、不必用电.在易燃、易爆场所使用安全可靠;

CIP清洗系统URS

第 1 页共 10 页 ********有限公司 *****车间CIP清洗系统URS 用户需求(URS)标准 使用部门文件编码 *****车间U R S02-029-00 起草人职务签名日期 年月日 年月日 审核人职务签名日期 年月日 年月日 年月日 年月日 审批人职务签名日期 年月日

变更控制记录 文件编码变更内容变更时间

1 概述 ********有限公司****车间共分三条生产线,CIP清洗系统为其中的A线使用,主要用于中药提取车间的浓缩、喷粉等设备在线清洗。本文件旨在从使用者的角度阐述用户的需求,包括了用户对该设备的功能、操作、GMP符合性、EHS等各方面要求,及用户对该设备的工艺过程的要求。这份文件是构建起本设备的文件体系的基础,同时也是设备设计和确认的可接受标准的依据。设备制造商应在规定时间内完成并达到用户需求的设计目标和可接受的质量标准。本URS是对CIP清洗系统的设计、制造、材料、运输、包装、安装、检查、测试、调试、运行、操作、维护、验证、文件和交付的说明和最低要求。 2 目的 该文件旨在从项目和系统的角度阐述用户的需求,概括了我公司对该项目的质量要求,生产能力要求。设备供应商应在规定的时间内完成并达到本用户需求设计的目标和可接受的质量标准。 3 范围 该文件是我公司****车间的项目计划,购置****车间的CIP清洗系统用户需求文件。 4 参考文件 《药品生产质量管理规范》 2010版 《工程设计规范》GEP 《药品GMP指南》2010版“厂房设施与设 备” 《工业自动化仪表工程施工及验收规范》 GB50093-2002 《钢制压力容器》GB150-1998 《机械安全》GB-52261-2002机械电气设备 第一部分:通用技术条件 《机电产品包装通用技术条件》GB/T13384-1992 5 设备介绍 5.1 组成:由纯化水贮罐,碱液贮罐,热水贮罐,板式换热器,循环泵,清洗泵,浓碱桶,气动隔膜泵,CIP回程泵,碱配液管道,热水循环管道,自清洗及罐排污管道等组成。

气动隔膜泵型号参数及使用

气动隔膜泵型号参数及使用 第四代气动隔膜泵,采用压缩空气为动力源,对于各种腐蚀性液体,带颗粒的液体,高粘度、易挥发、易燃、剧毒的液体,均能予以抽光吸尽。其性能参数与联邦德国的WLLDENPVMPS、美国的MARlOWPUMPS相近。 气动隔膜泵既能抽送流动的液体,又能输送一些不易流动的介质,具有自吸泵、潜水泵、屏蔽泵、泥浆泵和杂质泵等输送机械的许多优点。 一、气动隔膜泵优点 1、不需灌引水.吸程高达5m.扬程达70m.出口压力6bar。 2、流动宽敞,通过性能好.允许通过最大颗粒直径达10mm。抽送泥浆、杂质日寸,对泵磨损甚微; 3、扬程、流量可通过气阀开度实现无级调节(气压调节在1—7 bar之间): 4、该泵无旋转部件,没有轴封,隔膜j|等抽送的介质与泵的运动部件、工件介质完全隔开,所输送的介质不会向外泄漏。所以抽送有毒、易发挥或腐蚀性介质时,不会造成环境污染和危害人身安全; 5、不必用电.在易燃、易爆场所使用安全可靠; 6、可以浸没在介质中工作: 7、使用方便、工作可靠、开停只需简单地打开和关闭气体阀门.即使由于意外情况而长时间无介质运行或突然停机泵也不会因此而损坏.一旦超负荷,泵会自地动停机,具有自我保护性能,当负荷恢复正常后,又能自动启动运行; 8、结构简单、易损件少,该泵结构简单,安装、维修方便,泵输送的介质不会接触到配气阀,联杆等运动部件,不象其他类型的泵因转子、活塞、齿轮、叶片等部件的磨损而使

性能逐步下降: 9、可输送较粘的液体(粘度在1万厘泊以下): 10、本泵无须用油润滑,即使空转.对泵也无任何影响,这是该泵最大特点。 二、优势 采用压缩空气为动力源,对于各种腐蚀性液体,带颗粒的液体,高粘度、易挥发、易燃、剧毒的液体,均能予以抽光吸尽,尤以适合易燃易爆场。 三、能力 产品操作,安全可靠,耐腐蚀性,经久耐用,具自吸性,空转无损,多种材料,用途广泛,装置简单,免却维修。 四、应用市场 1、食品加工/生物卫生/制药 2、汽车/电镀和抛光

气动隔膜泵样本

First choice when Form No. 305-758Rev. B 2/98 Husky ? 3275 Air-Operated Double Diaphragm Pump quality counts.? The Husky 3275 is the biggest pump in Graco’s double diaphragm lineup. Its larger size enables it to deliver over 275 gallons (1041 liters) per minute.The lube-free Husky 3275 pump was engineered with the chemical, petrochemical, paper and mining industries in mind. It boasts the most reliable and trouble-free air switching valve in the world. The innovative design of the air switching valve prevents shut-down and air valve hang-up problems and can be serviced without disassembling the pump. The pump’s heavy-duty construction make it ideal for handling the most difficult chemical transfer, filter press feed, and dewatering applications. The most reliable and easy-to-service 3 in. (76 mm)pump on the market today! s Bolted leak-free flanged connections – no clamp bands used!s Large flow paths that can handle high viscosities s Easy air valve maintenance s Heavy-duty construction s Fluid flow up to 275 gpm (1040 lpm)

WILDEN气动隔膜泵手册

EOM E n g i n e e r i n g O p e r a t i o n &M a i n t e n a n c e Original ? Series METAL Pumps P15/PV15 S i m p l i f y y o u r p r o c e s s WIL -10110-E-02 REPLACES EOM-P15/PV15M 5/05

SECTION 1 CAUT I ONS—READ F I RST! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SECTION 2WILDEN PUMP DESIGNATION SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SECTION 3HOW IT WORKS—PUMP & AIR DISTRIBUTION SYSTEM . . . . . . . . . . . . . . . . . .3 SECTION 4 D I MENS I ONAL DRAW I NGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 SECTION 5 PERFORMANCE A. P15 Performance Curves Rubber-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 TPE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 PTFE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Ultra-Flex?-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 PV15 Performance Curves Rubber-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 TPE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 PTFE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Ultra-Flex?-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 B. Suction Lift Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 SECTION 6SUGGESTED INSTALLATION, OPERATION & TROUBLESHOOTING. . . . . . . .11 SECTION 7ASSEMBLY / DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 SECTION 8EXPLODED VIEW & PARTS LISTING P15 Metal Rubber/TPE/Ultra-Flex?-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 PTFE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 PV15 Metal Rubber/TPE/Ultra-Flex?-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 PTFE-Fitted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 SECTION 9 ELASTOMER OPT ONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

气动隔膜泵BQG-350-2操作手册

B QG QG--35350/0.0/0.0/0.22气动隔膜泵气动隔膜泵 操 作 和 维 护 手 册 执行标准:JB/T8697-1998 Q/IRGT009-2009 英格索兰(桂林)工具有限公司 广西桂林市朝阳路55号 邮编:541004 电话:(086)773-5878119 传真:(086)773-5876565 https://www.doczj.com/doc/2f13496290.html,

前言前言 使用本产品的用户使用本产品的用户,,请仔细阅读本说明书请仔细阅读本说明书,,以便正确使用本产品并充分发挥其优 良性能良性能。。 对未经咨询便对本产品擅自改动的用户对未经咨询便对本产品擅自改动的用户,,英格索兰公司对造成的伤害英格索兰公司对造成的伤害不不承担任何的责任的责任。。 本说明书包含重要的安全信息本说明书包含重要的安全信息。。 不遵守本手册规程不遵守本手册规程,,可能会造成人身伤害或财产损失可能会造成人身伤害或财产损失。英格索兰公司对造成的伤英格索兰公司对造成的伤害不承担任何的责任 害不承担任何的责任。 一.操作和安全预防措施操作和安全预防措施 阅读、理解并遵照此处信息操作,以免出现伤害或财产损失。 1、 气体压力过大。可能导致人员伤害、泵体损坏或者财产损失。 ① 进气压力不允许超过泵铭牌所注的最大允许值; ② 务必确保软管和其他部件能承受泵所产生的液体压力。检查所有软管的损坏或磨损 情况。确保分配装置干净,工作可靠。 2、 静电火花。可能发生爆炸。导致严重伤害或死亡。请将泵和泵送系统接地。 ① 火花可能点燃易燃材料和蒸汽; ② 当泵吸、冲洗、再循环或喷射易燃材料时,如油漆、溶剂、腊克漆等,或者在使用位置周围的环境大气可导致自燃时,泵送系统和喷射的物体必须接地。将分配阀或设备、容器、软管以及将材料抽吸到其中的任何物体接地; ③ 使用泵体上提供的接地端。使用ARO 零件号66885-1接地工具箱或将适当的接地线(最小12线规直径)连接到良好的接地点; ④ 确保泵体、连接头和所有接触点的安全,以避免振动和接触或产生静电火花; ⑤ 咨询当地建筑条例和电工规程中的特殊接地要求; ⑥ 接地后,定期检验接地电路的连续性。用欧姆计进行测试,确保每个部件(如软管、 泵、夹头、容器等)到接地端的连续性。欧姆计应当显示0.1欧姆或者更小的数值; ⑦ 将出口软管、分配阀门或设备浸入所分配的材料中,避免所泵送的材料自由流动; ⑧ 使用插有电线的软管; ⑨ 使用正确的通风设备; ⑩ 使易燃物品远离热源、明火和火花; ? 当不使用时,请关闭容器。 3、 泵排出物可能含有杂质。可能造成严重伤害。将排出物用管道从工作场所和操作 人员附近排走。 ① 万一隔膜破裂,可将物料从排气消声器强制排出; ② 当泵送危险或易燃物料时,将排出物用管道排到安全边远区域; ③ 在泵和消声器之间使用最小内径为3/4英寸的接地软管; 4、 危险压力。可能导严重伤害或者财产损失。 ① 当系统加压时不要维修或清理泵体、软管或分配阀; ② 打开分配阀或设备、并且仔细缓慢的从泵体松开和拆下出口软管或管道,以断开供 气管路并释放系统压力。 5、 危险材料。可能导严重伤害或者财产损失。 ① 不要将带有危险材料的泵返还工厂或维修中心。安全操作规范必须符合本地和全国

气动隔膜泵使用规范

气动隔膜泵使用规范 1、气动隔膜泵的安装: 1)气动隔膜泵尽量安装在靠近排水的地方,使吸入管线路最短、配置零件数量减少,但不能减少管路规格。 2)如果安装硬管道,在气动隔膜泵和管道之间要用短的软管来连接。软管可以减缓管道的振动和扭曲,推荐使用一个稳压罐来进一步减小流体中的冲。 2、气动隔膜泵的使用: 1)启动膈膜泵之前,要检查泵体螺丝及接头不能松动;检查泵体消音器安装完好;确认压风阀门处于关闭状态,排水出入口均处于全开状态。 2)缓慢开启膈膜泵压风阀门至1/2位置,启动膈膜泵。 3)待隔膜泵启动后逐渐开大膈膜泵气阀,直到全开。 4)如隔膜泵往复速度太快或噪音太大,应将气阀关小,以达最佳排水效果。 5)当排水完毕需停泵时,待让泵再运行三到四个往复,将水完全排出泵体后再关闭气阀。 6)气阀关闭后,有排水出口阀门的也应一并关闭。 7)如遇紧急情况需停泵只需关闭隔膜泵气阀即可,但随后要将泵 内的残留的水排出。 3、安全须知: 1)隔膜泵压缩空气压力不应超过0.7MPa.

2)流体中最大颗粒不超过10mm。 3)不允许隔膜泵长时间空运转。 4)当泵的隔膜失效时,输送的物料会从排气消声器中喷出,所以隔膜泵膜片破裂时,必须及时拆开清洗并更换膜片。 5)隔膜泵启动时应缓慢开启气阀,防止因突然开气阀引起隔膜泵剧烈震动而损坏设备。 6)在隔膜泵运行时严禁经带压维修,如要维修时,必须先切断泵的进气,打开旁通的卸压机构使管路系统卸压,然后慢慢松开连接的各管道接头进行维修。 7)保证泵压的管道系统能承受所达到得最高输出压力,保证驱动气路系统的清洁和正常工作条件。 8)必须使用至少1/2”内径内壁光滑的管道连接进气口。 9)必须对隔膜泵的消音器进行定期检查,严禁运行时的噪音超过85分贝。 10)保证所有的操作人员熟悉操作使用和掌握泵的安全使用须知。

不锈钢气动隔膜泵型号及参数

【QBY系列不锈钢气动隔膜泵】产品: 【QBY系列不锈钢气动隔膜泵】产品介绍: 生产的QBY系列气动隔膜泵是一种新型输送机械,是目前国内最新颖的一种泵类。隔膜泵是一种容积式泵,采用压缩空气为动力源,它集自吸泵、屏蔽泵、杂质泵、潜水泵等多种泵的优点与一身。对于各种腐蚀性液体,带颗粒的液体,高粘度、易挥发、易燃、剧毒的液体,均能予以抽光吸尽。 本厂目前已形成系列化生产,共有八种规格直径:Φ10mm(3/8'')、Φ15mm(1/2'')、Φ25mm(1'')、Φ40mm(3/2'')、Φ50mm(2'')、Φ65mm(5/2'')、Φ80mm(3'')、Φ100mm(4'')。三种材质、铝合金、铸铁、不锈钢。隔膜泵根据不同液体介质分别采用丁晴橡胶、氯丁橡胶、氟橡胶、聚四氟乙烯。以满足不同用户的需要。 该泵以被国内石油、化工、电子、陶瓷、纺织系统单位广泛采用,安装在各种特殊场合,用来抽送各种常规泵不能抽吸的介质,均取得了满意的效果。 【QBY系列不锈钢气动隔膜泵】型号意义:

【QBY系列不锈钢气动隔膜泵】主要特点: 1、无轴封、无泄漏、流道宽敞,所以输送含颗粒,高粘度(粘度可达1万厘泊),易挥发和腐蚀性介质时,不会造成环境污染和危害人身安全。 2、无旋转部件,通过性能好,允许通过最大颗粒直径达10mm。液体无剪切流动,泵自身部件磨损小。对输送物损伤小,可输送污泥和生命体如小鱼苗之类。 3、不需灌引水,自吸能力强,吸程高达7m,长时间干呼吸,对泵不损坏。一旦超负荷,泵便会自动停机,负荷恢复正常时,能自动启动运行,具有自我保护功能(电动泵无此功能)。 4、气动泵扬程达50m,电动泵达30m,出口压力最大可达0.6mpa。扬程、流量可通过气阀开度实现无级调节,气压调节在1-7kgf/cm2之间。电动泵无此功能,进口需装调节阀控制。 5、气动泵可以浸没在介质中工作,无电源通过,安全可靠(电动泵无此性能)。 6、气动泵不需电源,更适合易燃、易爆场合的介质输送。 【QBY系列不锈钢气动隔膜泵】技术参数: 流量:0-30m3/h; 扬程:0-50m; 口径:10-100mm; 温度:-15-+120℃; 压力:0.1-0.7MPa; 自吸高度:5-7m。 【QBY系列不锈钢气动隔膜泵】工作原理: QBY气动隔膜泵有两个对称的工作腔,各装有一块弹性隔膜,连杆轴将两块隔膜联接,当压缩空气由进气接头经配气阀进入A工作腔推动隔膜,该腔进口球阀关闭,出口球阀打开,液体排出,于此同时,B腔隔膜由连杆轴驱动背面气体排入大气,出口球阀关闭,进口球阀打开,液体被吸入(见图A)。当行程到达终点,配气阀将气体导入B工作时,情况同前述相反,B腔排出液体,A腔吸入液体。如此反复,泵不断吸入排出液体。

ph计测量校准过程中常见的问题以及解决方法

PH计测量校准过程中常见的问题以及解决方法测量问题:同一样品,两次测量的pH值不一样? 温度变化或样品本身发生了化学反应,都会引起pH值的变化。所以,应尽量保持温度一致,并且避免化学反应。 测量问题:同一样品,同时在两台pH计上测量,读数不一致 由于两台pH计的校正条件不一样(如不同时间做的校正),造成测量值有差异。所以要用同一缓冲液在同一时间里对pH计进行校正,然后再同时测定。 测量问题:不管电极在何样品中,显示不变? 因为电极没有真正连接到仪表上。处理方法是首先关机,然后将电极和仪表重新连接。·因为电极是坏的,要及时更换新的电极。 测量问题:PH计测量不稳定,时间长 因为电极老化。可以测试电极在缓冲液中的响应时间,若大于1分钟,需要对电极进行活化处理或更换新电极。 若测量缓冲液响应时间很短,但测量样品不稳定,说明电极不适合测量该被

测样品,请根据电极选型指导选择合适的电极。校准问题:为什么电极放在 pH7.00的缓冲液中校正后,显示为7.02? 此时缓冲液温度在20°C左右。由于缓冲液的pH值会随温度变化有小量变化,7.00只是缓冲液在25°C下的值,而缓冲液在20°C时的值应为7.02。梅特勒-托利多的pH计能自动补偿温度对缓冲液的影响以保证测量精度。 做第二点校正时出错或不能校正? 由于中途退出了校正。在校正过程中,只要按“Cal”键即可,不要碰其它键,否则就会退出校正程序。 校准问题:校正斜率大于105%时该如何处理? 检查缓冲液是否已经过期。如过期,要更换新的缓冲液。 校准问题:为什么缓冲液在有效期内已经变质不能使用了? 缓冲液的有效期是指未开封使用状态下的保存期。一旦开封使用后,由于空气中各种霉菌的作用,缓冲液较易变质。 注意:已使用过的缓冲液,千万不能倒回原装瓶中!

气动隔膜泵使用说明

气动隔膜泵使用说明 气动隔膜泵工作原理: 气动隔膜泵是以压缩空气为动力和按照1∶1 比率的设计而进行工作的。一个隔膜室的内侧将被交替地增压而同时另一个隔膜室被排空。这会导致通过紧固在隔膜中央(以金属板连接)的普通杆连接的隔膜产生摆动。(因为一个隔膜在执行排放冲程而另一个则在对应的隔膜室中被拉动并执行吸气冲程)。空气压力作用于隔膜的整个内表面,同时液体从隔膜的对应侧排出。隔膜在排放冲程期间以平稳的状态工作,同时允许泵以超过200 英尺(61 米)水柱的输送压头进行工作。为获得最长的隔膜使用期,应使泵尽可能靠近被泵输送的液体。当正的吸入压头超过10 英尺(3.048 米)的液体高度时,可能需要一个背压式调节装置,以最大限度地提高隔膜的寿命。对隔膜室的交替式增压和排空通过一个安装在外部的液控4 路阀芯式空气分配阀来实现。当阀芯移动到阀体的一个端头时,入口压力作用于一个隔膜室,而另一个隔膜室则被排空。当当阀芯移动到阀体的另一端头时,作用于隔膜室中的压力相反。空气分配阀的阀芯通过内部的控制阀来移动,该控制阀轮流施压于该空气分配阀的阀芯的一个端头,而排空另一一个端头。当隔膜板接触到执行器的柱塞时,控制阀会在隔膜冲程的每一端移动。然后该执行器的柱塞就会将控制阀的阀芯的端头推向启动空气分配阀的位置。隔膜室与带有为每一个隔膜室配备的进水管和出水管止回阀的歧管相连,保持液体通过泵的单向流动。气动隔膜泵的安装和启动:

尽可能将气动隔膜泵定位于靠近被输送的液体之处。将吸入管路的长度和接头配件的数量降低到最小。不要减少吸入管路的直径。在安装刚性管路时,应在隔膜泵和管路之间安装短的挠性软管段。挠性软管可以减少输送系统的振动和拉紧。建议采用增稳装置减少流动中产生的振动。 气源: 供气压力不得超过125psi(8.6 巴)。将泵的空气入口连接到所需的气源中,该气源应有足够的容量和压力,并达到期望的特性。当进气管为刚性管路时,在泵和管路之间安装一个直径不超过1/2″的短的挠性软管段。以降低管路的张力。供气管路的重量、调节器和过滤器必须由除进气帽外的一些装置予以支撑。缺乏对管路的支撑会导致泵的损害。应安装压力调节阀以确保供气压力不超过建议的限值。气阀的润滑: 空气分配阀和控制阀被设计成无需润滑就可以工作的模式。这是操作的最佳模式。也可能有一些个人的偏好或较差质量的供气,从而产生对压缩空气的供气阀(pneumatic valve)进行润滑的需求。泵的空气系统和经过正确润滑的压缩空气的供气阀一起工作。正确的润滑需要使用一个固定的空气管路注油器,以在空气中20 标准立方英尺/分钟(9.4 升/秒)的速度传输SAE 的10 种非清洁剂的润滑油中之一的润滑剂。泵在工作时耗油。查阅已发布的有关泵的特性曲线,以确定所需的润滑油。 空气管路中的水分:

气动隔膜泵操作运行时要注意要点及维护和保养

气动隔膜泵操作运行时要注意要点及维护和保养 (文章来源阳光泵业https://www.doczj.com/doc/2f13496290.html,) 气动隔膜泵是以压缩空气为动力,通过膜片往复变形造成容积变化的容积泵,其工作原理近似于柱塞泵。 (第四代QBY型气动隔膜泵产品图片) 气动隔膜泵操作运行时要注意以下几点: 1、保证流体中所含的最大颗粒不超过泵的最大安全通过颗粒直径标准。 2、进气压力不要超过泵的最高允许使用压力,高于额定压力的压缩空气可能导致人身伤害和财产的损失及损坏泵的性能。 3、保证泵压的管道系统能承受所达到得最高输出压力,保证驱动气路系统的清洁和正常工作条件。 4、静电火花可能引起爆炸导致人身伤亡事故和财产的损失,根据需要使用足够大截面积的导线,把泵上的接地螺钉妥善可靠接地。 5、接地要求符合当地法规法律要求及现场的一些特殊要求的规定。 6、紧固好泵及各连接管接头,防止因振动撞击擦产生静电火花。使用抗静电软管。 7、要周期性的检查和测试接地系统的可靠性,要求接地电阻小于100欧姆。 8、保持良好的排气和通风、远离易燃易爆和热源。

9、泵的排气中可能含有固体物,不要将排气口对着工作区或者人,以免造成人身伤害。 10、当隔膜失效时,输送的物料会从排气消声器中喷出。 11、当输送易燃和有毒的流体时,请将排口接到远离工作区的安全地方。 12、请使用至少3/8"内径内壁光滑的管道连接排气口和消声器。 13、流体的高压可能会导致严重的人身伤亡和财产损失,请不要在泵加压时,对泵及料管系统进行任何的维修工作,如要做维修时,先切断泵的进气,打开旁通的卸压机构使管路系统卸压,慢慢松开连接的各管道接头。 14、如输送的有害有毒流体泵,请不要把泵直接送到厂家来修理。根据当地法律法规妥善处理,并使用上海旺泉泵业公司纯正配件以保证使用寿命。 15、液体输送部分使用铝合金材料的泵,请不要用来输送含有Fe3+的液体和卤代烃及其他的卤代碳氢化合物溶剂,则将会产生腐蚀引起泵体爆裂。 16、保证所有接触输送体的部件不会被输送的流体腐蚀损坏。 17、保证所有的操作人员熟悉操作使用和掌握泵的安全使用注意事项,必要的话,配给必需的防护用品。 18、正确使用泵,不允许长时间的空运转。 气动隔膜泵的维护和保养 确保气动隔膜泵始终处于良好的运行或备用状态。所有大厦安装的生活气动隔膜泵,消防泵、喷淋泵、补压泵、排污泵、空调气动隔膜泵。由管理处维修人员负责气动隔膜泵定期保养。 一、生活气动隔膜泵和空调气动隔膜泵每周进行一次日常检查保养,每半年进行一次全面保养。 二、消防气动隔膜泵和喷洒泵每一个月、补压泵每二月进行一次试运行,运行时间10-15分钟,消防泵起动时在管网顶部试消火栓出口喷水射程达6M以上,每半年进行一次全面保养。 三、排污泵、潜气动隔膜泵每半年进行一次全面保养。 四、气动隔膜泵保养时应把与泵体相连的2米范围内阀门、压力表、管道等随泵同时保养。 五、泵体的保养