COMMENTARY TO AG:PT/T102 – PROTOCOL FOR HANDLING MODIFIED BINDERS IN PREPARATION FOR LABORATORY TESTING AG:PT/T102—为实验室测试制备改性粘合剂的处理草案PREFACE前言

This Modified Binder Test Method was prepared by the Bituminous Surfacings Research Reference Group BSRRG (formerly National Bituminous Surfacings Research Group) on behalf of Austroads. Representatives of Austroads, ARRB Group and Industry through the Australian Asphalt Pavement Association (AAPA) have been involved in the development and review of this test method.

本改性粘合剂测试方法是由BSRRG(前国家沥青表面研究小组)以Austroads名义撰写的

本改性沥青检测方法是由BSRRG以Austroads名义撰写的。Austroads的代表,ARRB行业研究小组通过AAPA已经从事开发和审核本检测方法。

FOREWORD序

Modified binders are heat-sensitive materials and may undergo significant changes in test results and ultimately to their properties as a result of exposure to high temperatures for extended periods. An additional potential problem is that they may separate from the modified binder dispersion. Improper heating and homogenisation of samples can, therefore, affect the test results obtained on sampled binders, which may thus not truly represent those of the original material.

改性粘合剂是热敏材料并且可能在测试结果中经受重大变化,作为长时间暴露在高温下的结果最终达到其性能。

Recent testing experience, particularly with those binders formulated with SBS polymer at concentrations greater than four percent suggests that the manner of binder handling prior totesting can significantly influence the (empirical) test results. This laboratory handling protocol represents agreed best practice based on an extensive period of review and evaluation.

最新测试经验,尤其是用浓度大于4%的SBS聚合物配置的那些粘合剂,在测试能重大影响(实证的)测试结果之前建议给出了粘合剂处理方式。

Estimates of precision reported by Austroads and included in test methods released since 2002 were obtained on modified binders handled with this protocol.

从2002年已经用本草案在处理改性粘合剂上得到Austroads所报告的评估精度且包含在发布的检测方法中。

SCOPE范围

This test method adopts the principles of AS 2341.21 and applies these to modified binders that are to be tested in accordance with the test methods set out by Austroads. Such binders include polymer modified bitumen and multigrade bitumen.

本检测方法采用AS 2341.21原理并按照Austroads所述的检测方法运用这些到要测试的

改性粘合剂。这样的粘合剂包括改性沥青和多级沥青。

Further Development进一步研发

This test method is a key component of laboratory best practice for the testing of modified binders. Further improvements will be introduced as they become available.

本检测方法是改性粘合剂测试实验室最好的实践的关键部分。当其有效可用时进一步的改进会被推出。

PROTOCOL FOR HANDLING POLYMER MODIFIED BINDERS IN THE LABORATORY

实验室改性沥青处理草案

1 REFERENCED DOCUMENTS

参考文献

The following documents are referred to in this method:本方法涉及下面的文献AUSTROADS

AG:PT/T101 Method of sampling polymer modified binders, polymers and crumbrubber

改性沥青,聚合物和橡胶粒的取样方法

AS

2341 Methods of testing bitumen and related road making products

测试沥青和相关道路制品的检测方法

2341.21 Sample preparation

样品制备

ASTM

E 1 Standard specification for ASTM thermometers

ASTM温度计E 1 Standard标准规格

IP Methods for analysis and testing, Part 1, Vol. 2, Appendix A

分析和测试IP方法,1部,2卷,附录A

2 PRINCIPLE原理

The objective of this procedure is to ensure that modified binder samples, when tested, are representative of the product as sampled. To achieve this, samples must undergo a minimum and controlled amount of heating. A flow chart of the prescribed handling procedure options is set out in Appendix A.

本程序的目标是确保当测试时,改性沥青是被抽取的代表性产品。为了实现此目的,样品必须经历最小和受控的加热。规定的处理程序可选的流程图设置在附录A.

3 APPARATUS仪器

a. Pre-heating oven - able to maintain a temperature of 160 ±10 °C. May be fitted with

a timer switch.

预热烘箱—能保持160 ±10 °C的温度。可以配置定时装置。

b. Forced draught oven - able to maintain a temperature in the range 100 to 200 °C,

with a set-point accuracy better than ±5 °C.

强制通风烘箱—能保持温度范围为100 to 200 °C,设定值精度高于±5 °C为佳。

c. Thermometer - conventional mercury-in-glass, partial immersion thermometer for hotplate use and oven monitoring, accurate to 0.5°C. A suitable thermometer is IP

61 C or ASTM 16C, as specified in ASTM E 1, for use at around 200 °C.

温度计—常规水银玻璃,热板或烘箱使用部分浸入温度计监控,精确到0.5°C.。适合的温度计为IP61 C 或ASTM 16C,如ASTM E 1规定,用在大约200 °C。

d. Mechanical stirrer - with impeller able to maintain the stirring characteristics

described in Appendix B

机械搅拌器—带叶轮能维持附录B所述的搅拌特性。

e. Heating block - aluminium block, e.g. 150 mm diameter, with a cavity able to accept a nominal 400 mL beakers with a clearance up to 2 mm.

加热块—吕块,例如150mm直径,带凹处能接受一个公称400ml,刻度间隙为2mmde 烧杯

f. Beaker – nominal 400 mL (or equivalent container) to fit the heating block withsuitable lid e.

g. standard 500 mL paint container with lid is suitable and can bediscarded after use.

烧杯—匹配加热块,公称尺寸400ml(或者同等容器)且有匹配的盖子。例如,标准的500ml 的带盖容器是适合的并且可以在使用后被丢弃。

g. Temperature controllable hotplate - able to maintain a temperature in the range 135

- 200°C, with a set-point accuracy of ±5°C.

控温热板—能维持温度范围135- 200°C,设定值精确到±5°C

h. Temperature controller - an alternative to the temperature controllable hotplate is described in Appendix C. This system uses an oven temperature controller withPt100 remote temperature sensor. Better temperature control is provided along withdirect temperature readout. No monitoring thermometer is required after systemcalibration check.

温度控制器—附录C中所述可以控温变化的加热板。该系统使用Pt10远程温度传感器的烘箱温度控制器。随着直接退去温度提供好的温控控制。在系统校准检查后不需要监控温度计。

i. Temperature probe - a suitable probe based on a thermocouple or Pt100 used inconjunction with a corresponding readout device, with an accuracy of ±2 °C.Alternatively, a suitable thermometer (or equivalent) may be used.

温度探针—合适的探针基于热电偶或Pt100,用在相应读数装置的连接处,精确到±2 °C。或者,使用合适的温度计(或同等的)。

j. Stirrer – flat blade spatula, suitable for the containers used.

搅拌器—平面叶片抹刀,适合使用的容器

k. Beaker(s) - 250 - 300 mL sub-sample containers.

烧杯--250 - 300mL子样品容器。

Note 1 Some apparatus items are optional depending on method selected

注释1 一些仪器根据选择的方法可选用

4 PROCEDURE程序

4.1 General概要

Modified binders can be complex mixtures of polymers and a variety of petroleum products. If handled in accordance with the directions of the suppliers, there should be no significant safety risk. It is recommended that notices, describing the action to be taken in the event of hot binder burns, should be displayed in the laboratory in the areas where bitumen, multigrade and PMBs are handled. A suitable warning could be as follows:

改良粘合剂是聚合物和不同是有产品的复杂混合物。如果按照供应商指导处理,则不会有重大的安全风险。在此推荐警示所描述的在热粘合剂燃烧放生时采取的行动,应在沥青,多级和改性沥青被处理的实验室区域展示。适当的警示可以如下:

警告:热沥青,多级和改性沥青可能导致燃烧

The following precautions should be taken when handling hot bituminous binders, such as bitumens, multigradebitumens, polymer modified bitumens and crumb rubber modified bitumens:

当处理热沥青粘合剂时应采取下面的防护措施,如沥青,多级沥青,改性沥青和橡胶粒改性沥青:

a. Eye protection, such as safety glasses and/or face shields, shall be worn whenhandling hot bituminous binders.

眼部保护,如护目镜和/或面罩,应在处理热沥青粘合剂时穿戴。

b. Heat-resistant gloves with close-fitting cuffs, and other suitable protective clothing,shall be worn when handling hot bituminous binders.

贴身袖口的隔热手套,及其他适合保护的服装,在处理热沥青粘合剂的时候应穿戴。c. There shall be no smoking or the presence of other ignition sources in closeproximity while handling hot bituminous binders.

处理热沥青粘合剂时,在附近不应有烟或出现其他火源。

d. Bituminous binders heated in the presence of small quantities of water may foamexcessively and spatter or overflow the sample containers. Samples should bechecked for the presence of water while the material is still cold. First loosen the lidof the sample container, if necessary by gently heating the container lid, and examinethe cold sample for the presence of water. If water is found to be present, drain offas much as possible and allow to dry at room temperature or blow-dry with cleancompressed air.

加热沥青粘合剂存在少量的水可能大量起泡并溅出或者溢出样品容器。当材料还是冷的时候应在检查样品的水分。首先松开样品容器的盖子,如有必要通过微微加热容器盖子,检查冷的样品水的存在。如果发现有谁,尽可能排出并允许在室温下干燥或用清洁的压缩空气吹干。

4.2 Sampling取样

a. An original sample shall be obtained in accordance with the procedures set out

inAGPT/T101.

按照AGPT/T101设定程序取得原样

Note 2 Samples taken from, production, bulk storage, and transporttankers or during transfer from or into these vessels shall be treated asoriginal samples.

注释2 从生产,存储和运输罐车或转运期间从或在这些容器内取得的样品被视为原样。

b. If the original sample has just been taken and the viscosity is low enough (i.e.temperature is 160 oC or higher), it can be reduced, after suitable stirring, into subsamples for later testing. Note that these samples must be allowed to cool to below60°C before reheating and testing (testing of hot poured original samples willgenerally give higher test results). These smaller sub-samples shall be re-heatedonly once prior to testing (see 4.5 and 4.6).

如果已经取得原样并且粘度足够低(例如,温度在160 oC或更高),在适当搅拌后,可以将其缩分成子样用于稍后测试(热到倒出的原样测试通常给出更高的测试结果)。这些小点的子样应在测试前只被加热一次(见4.5和4.6)

4.3 Sample Reduction – Cold Bulk (Sample < 160 °C)

样品缩分—冷的(样品< 160 °C)

4.3.1 Hotplate method热板法

a. Preheat the bulk sample in the preheating oven set at 160oC

Note 3 Heating times vary according to oven type, sample size andinitial temperature. A minimum of four hours is generally required if thesamples are larger than 4 L. Samples must not be heated for more than tenhours at 160 °C. The use of a timer switch is recommended to allowpreheating to commence overnight.

在设置温度在160oC的预热烘箱中预热样品。

注释3 加热时间变换按照烘箱类型,样品尺寸和初始温度。如果样品大于4L,通常需要最少4小时。推荐使用定时开关以便让预热从头晚开始。

b. Place the sample onto the hotplate and commence stirring with a spatula withoutentraining air, occasionally scraping the sides and the bottom of the container. Whenthe sample is of uniform consistency, check its temperature with a thermometer andcontinue stirring.

把样品放在热板上并用抹刀开始搅拌,不要带路空气,偶尔抹下容器各面和底部。当样品具备统一的稠度,用温度计检查其温度并继续搅拌。

c. When the sample reaches 160 °C, divide the bulk sample into sub-samples usingsmaller containers (1 L or less). Remove the bulk container from the hotplate.Note 4 At this stage, check the material for any unusual or unexpectedphysical properties, such as extreme fluidity, cutter odour, fume, or highconsistency. If the presence of cutter, or other volatile oil, is suspected, athin film dish or RTFO treatment bottle may be poured at this stage for further testing (mass loss determination).

当样品达到160 °C,使用较小的容易(1L或更小)把样品分成子样品。从热板移除样品容器。

注释4 在此阶段,检查材料的乐呵异常或非预期的物理性能,如极端的流动性,轻质油气味,烟或高稠度。如果质疑轻质油或其他挥发油出现,可以在此阶段倒入薄膜盘或RTFO 处理瓶进一步测试(测定质量损失)

4.3.2 Oven method烘箱法

a. Set the fan forced oven to 180 °C.

设置强力通风烘箱到180 °C

b. Heat the bulk sample to 160 °C, allowing sufficient time to reach this temperature.This temperature is check by inserting a temperature probe into the sample or timedaccording to the appropriate heating time as determined in procedure set out inAppendix B.

加热样品到160 °C,允许充分的时间到达该温度。通过插入温度探针到样品中或根据附录B设定在测定程序里的适当的加热时间定时检查此温度。

c. Remove the bulk sample from the oven and thoroughly stir it for 30 seconds with aspatula without entraining air.

从烘箱移除样品并用抹刀彻底搅拌30秒,没有带入空气。

d. Divide the bulk sample into sub-samples in containers of 1 L, or less. Some or all of

these samples may be further heated in preparation for pouring into test moulds for testing by the procedure in 4.5. At this stage, check the material for any unusual or unexpected physical properties (see Note 3 above).

把样品缩分到1L容器的子样品,或更少。一些或所有这些样品可以被进一步加热,准备倒入试模按4.5的程序测试。在此阶段,检查材料的任何异常或非预期微粒特性(见上面的注释3)

4.4 Sample Reduction –Hot Bulk (Sample ≥ 160 °C)

样品缩分—热的(样品≥ 160 °C)

4.4.1 Hotplate method热板法

a. If the bulk sample is 160 °C or hotter it may be sub-sampled without heating bystirring for at least 30 seconds with a spatula and decanting into containers, 1 L orsmaller, and allowed to cool.

如果样品是160 °C或更热,其可以在无加热下通过用抹子搅拌至少30秒并倒入1L或更小的容器得到子样品并允许冷却。

Note 5. If immediate testing is required the sub-samples must first beallowed to cool to below 60 °C before reheating according to 4.5 or 4.6 forpouring of test moulds. Sample reduction from bulk (see Note 9

注释5 如果需要立即测试,子样必须依照4.5或4.6为倒入试模再加热前,首先被允许冷却到60 °C以下。样品缩分(见注释9

4.5 Sub-sample Preparation for Testing (Hotplate Method)

为测试制备子样(热板法)

a. Take sub-sample as already decanted at stage 4.3.1 (c) or 4.3.2 (d).

取子样如在4.3.1 (c) 或4.3.2 (d)已经轻轻倒出的。

b. Set the temperature controlled hotplate to 180 °C and allow temperature to stabilise.

c. Heat the sub-sample(s) to 180 °C in the preheated aluminium block. Do not hold at180 °C for longer than 30 minutes.

在预热的吕块里加热子样到180 °C。不要在180 °C保持超过30分钟。

Note 6 TheAluminium block can be brought to the working temperatureon the hotplate or by

pre-heating in an oven.

注释6 吕块可能在热板上或通过在烘箱中预热被带到工作温度。

d. Stir the sub-sample with a mechanical stirrer and suitable impeller for 30 secondswithout entraining air (refer to Appendix C).

用机械搅拌器和适合的叶轮搅动子样30秒,没有带入空气(指向附录C)

e. Fill the required test containers.

填装需要测试的容器

f. Discard the remnants of the heated sub-sample(s). Do not add to current workingstock.

丢弃残余的已急了子样。不要加入到现有日常储存中。

4.6 Sub-sample Preparation for Testing (Oven method)

为测试制备子样(烘箱法)

a. Take sub-sample as already decanted at stage 4.3.1 (c) or 4.3.2 (d). and place in anoven set at 180 oC

取得如在4.3.1 (c) 或4.3.2 (d)阶段已经轻轻倒入的子样并把烘箱设置在180 oC。

b. The samples are to be heated for a minimum time as determined under theprocedure set out in Appendix B2 to achieve a temperature of at least 170 oC.

如附录B2里设定的程序下测定的最短时间急热样品以达到至少170 oC温度。

c. Remove the sub-sample tin from the oven and immediately transfer to a hot plateand commence stirring (manual or slow mechanical) until a binder pouringtemperature of 180 oC has been reached (time taken must not exceed 30 minutes).

从烘箱移除子样罐并立即中转到热板并开始搅拌(手动的或机械缓慢的)知道粘合剂倒出的温度已经达到180 oC(时间必须不超过30分钟)

d. Pour the test moulds without delay and schedule testing according to the respectivetest method.

没有耽搁下倒入试模并按照独立的检测方法安排测试。

Note 7. For multiple sample testing ensure that only that number of subsamples is preheated as can be poured within 15 minutes (i.e. oldest subsample is held for no more than 15 minutes at 180 oC).

注释7 对于多重抽样测试确保只有子样品数是按15分内可以倒完预热的(例如,保持最早的子样在180 oC不超过15分钟)

4.7 Testing of Hot Production Samples

热生产样品的测试

a. If the sample is below 175 oC heat the sample tin in a forced draught oven or on ahotplate until the sample reaches 180 ±5 oC. For samples at or above 175 oCproceed to 4.7(b).

如果175 oC 以下的样品在强力通风烘箱或热板上加热样品罐知道样品达到180 ±5 oC。对于在175 oC或其上的样品继续4.7(b).

b. Stir and fill the required test containers and allow the binder to cool. Unused binderhandled at or above 175 oC (i.e. without reheating) may be reheated one more timefor testing if required i.e. can be treated as a sub-sample under 4.5 or 4.6.

搅拌和装填需要测试的容器并允许粘合剂冷却。在175 oC处理的未使用的粘合剂(例如没有再加热)如需要可以为测试再加热一次,例如在4.5或4.6下被视为子样品。

Note 8. Where disputes arise between manufacturer and user of thebinder, test properties shall be determined on samples prepared from coldproduct. Manufacturers testing hot poured samples under 4.7 must ensurethat the relevant specifications can also be met by testing of samples cooledto below 60 °C.

注释8当厂商和粘合剂使用者之间有争议,测试性能则从冷产品中制备样品来测定。在4.7下厂商测试热倒出来的样品必须通过样品冷却到60 °C以下的测试确保也能达到相关规格

5. REPORT报告

The following information shall be reported:

应报告下面的信息

a. Sample history including the preparation method.

样品历史包括制备方法

b. The presence of fumes or cutter odour.

出现烟或轻质油气味

c. The presence of foaming.

出现起泡

d. Unusually high consistency or inhomogeneity.

非正常的高稠度或不均质性

附录A(规范的)样品处理方案选项

APPENDIX B附录B

(Normative)(规范的)

Heat-up rate of sample in forced draught oven

样品在强力通风烘箱的加热速度

B1 GENERAL概要

During the preparation of bulk samples for sub-sampling, the minimum time required for a bulk sample to reach the desired temperature (e.g. 160 °C or 180 °C) must be known.

在为取子样品而制备样品期间,必须明确样品到达预期温度(例如160 °C 或180 °C)需要的最短时间

In preparing sub-samples for testing, the minimum time required for the particular size of container to attain the filling temperature must be known.

在为测试制备子样品中,必须明确特定尺寸的容器达到装填温度需要的最短时间。

The procedure below shall be carried out, as required, for each size of container used during the forced draught oven sample preparation in this method

按需要,本方法中在强力通风烘箱样品制备期间对不同大小的容器应执行下面的程序:

B2 PROCEDURE程序

The procedure shall be as follows:

程序应如下:

a. Insert a thermocouple into the sample as follows:

如下插入电热偶到样品中:

(i) Punch a hole through the lid of the container.

在容器的盖子上打孔

(ii) Fill the container with the sample and secure the lid.

用样品装填容器并盖紧盖子

(iii) Allow the sample to cool until it is semi-solid.

允许样品冷却直到其成半固态。

(iv) Insert the temperature probe through the hole to half the sample depth andsecure it to ensure the probe tip does not move as the sample softens duringthe heating and monitoring phase.

通过孔插入温度探针到样品的一半深度并固定好它以去报探针头部在加热和监控阶段不会随样品软化而移动

(v) Cool the sample to room temperature.

冷却样品到室温。

b. Set the oven to the required temperature, viz. 1 60 °C when using bulk samples, or180 °C when using sub-samples.

设置烘箱到需要的温度,当使用样品时即1 60 °C,或当使用子样品时即180 °C。

c. When the temperature has stabilised, place the sample in the oven on the shelf andin the position normally used for heating bitumen samples. Leave the temperatureprobe in place and close the door on the thermocouple wire (these wires can bepassed thoughan oven top vent if required).

当温度已经稳定,把样品放到烘箱的架子上并通常在加热沥青样品的位置。在该处留下温度探针,在电热偶线线上关门(如需要,这些线可以穿过烘箱的顶部出风口。

d. Monitor the temperature with time and establish the minimum time required for

the sample container to reach within 5 ?C of the required temperature.

用时间监控温度并确立样品容器达到在需要的的温度5 ?C内的最短时间。

e. Remove the container, cool to room temperature and repeat Steps (a) through (d) forother relevant container sizes.

移除容器,冷却到室温并对其他相关尺寸的容器重复步骤(a)到(d)。

Note B1: Alternatively, a suitable thermometer can be used in place of the temperature probe.

注释B1:或者,可以在温度探针的地方使用适合的温度计

Note B2: If the laboratory sometimes tests several samples at the one time, the above procedure should also be carried out with the monitored sample surrounded by

bitumen-filled dummy containers.

注释B2:如果实验室有时同时测试几个样品,也可以用被装填沥青的虚拟容器包围的被监测样品执行上面的程序。

Note B3: Glass beakers and metal containers with cut-off rims will require lids.

注释B3:玻璃烧杯和带套环的金属容器会需要盖子。

B3 RECORDING记录

The following information shall be recorded:

应记录下面的信息

a. The minimum time required for a particular size of bulk sample container to reach155 °C (for 160 °C set point).

特定大小的样品容器达到155 °C ( 160 °C为设置点)需要的最短时间.

b. The minimum time required for sub-sample containers intended to be used to reach175 °C (for 180 °C set point).

打算使用的子样品容器达到175 °C( 180 °C 为设置点)需要的最短时间。

APPENDIX C附录C

(Normative)规范的

Mechanical stirrer and impeller

机械搅拌器和叶轮

C1 GENERAL概要

For sample mixing to be repeatable and reproducible between laboratories, the rotational speed, paddle design and sample container should be adequately defined. By defining the sample size at 1 Litre, and specifying the impeller the geometry of the system is established. The chosen system is described as a low shear rate mixer and is not intended to blend the polymer into the binder. Its purpose is to ensure a homogeneous system for well manufactured binders by overcoming any segregation which may have occurred in the original sample.

对于实验室间可以重复混合和再生的样品,应适当规定旋转速度,叶片设计和样品容器。通过规定样品大小为1升,并且指定的叶片的几何形状的系统被建立。描述被选择的系统作为低切变速度的混合器并且不会混合聚合物到粘合剂中。它的目的是通过克服可能已经出现在原样中的任何离析为生产好的粘合剂确保均匀系。

C2 EQUIPMENT DEFINITION

设备定义

For the 1997 PMB inter-laboratory precision exercise, a commercial paint stirrer (impeller) was chosen for its availability and simple design. Figure C1 describes the paddle and

provides the important dimensions (informative only). A simple impeller should be selected to ensure the incipient vortex described in Fig. C2 can be sustained with the available mechanical stirrer. A high shear mixer e.g. Silverson type, is not suitable for this test method. 对于1997年PMB内部实验室精度试样,商用油漆搅拌器(叶轮)被选取缘于其可用性和简单设计。图C1介绍了划桨并提供重要的尺寸(仅为告知性的)。应选择简单的叶轮以确保用有效的机械搅拌器可以维持图C2介绍的的初期的漩涡。高切变混合器,例如Silverson型号,不适合本检测方法。

The mechanical stirrer is a general purpose laboratory stirrer with variable speeds. The combination of stirrer and paddle with an appropriate rotational speed ensures that during the stirring process, the surface of the sample will be on the verge of forming a vortex. The maintenance of this incipient vortex ensures adequate mixing without the entrainment of air into the sample. Figure C2 describes the ideal mixing condition.

机械搅拌器通常用作实验室搅拌器可以变速。搅拌器和划桨的结合伴以适当的旋转速度确保在搅拌的过程中,样品表面会在形成的漩涡边缘上。该初期漩涡的维持确保正确的混合没有将空气卷入到样品中。图C2介绍了理想的混合条件。

图B1:叶轮装配

轴直径6mm,长250mm,

叶片内径30mm,直径50mm,角度越30度

图B2:初期的漩涡

漩涡在搅拌过程的任何阶段都肯定不能混乱。搅拌器电机的速度调整到空气滞留的短点

APPENDIX D附录D

(Informative)(告知性的)

Electronic Temperature Controller

电子温控

D1 GENERAL概要

Sample heating using the temperature controlled hotplate, heating block and thermometer can be difficult to manage both in terms of control precision and temperature stability. The lack of a direct temperature measurement link between the sample and the hotplate is the primary cause of these deficiencies.

使用温控热板,加热块和温度计对样品加热可能对控制精度和温度稳定性都管理困难。在样品和热板间缺少直接的温度测量环节是这些缺陷的首要原因。

D2 EQUIPMENT设备

Several electronic controller manufacturers have released cost effective modules fortemperature control in a variety of application. These devices can be seen in recently manufactured laboratory ovens, MATTA test cabinets and Durability ovens and provide a high level of stability through the use of a Platinum resistance (Pt100) sensor. Otherfeatures are:

几个电子控制厂商已经发布对不同应用的温控发布了性价比高的模具。最近生产的实验室烘箱可见这些装置,MATTA测试柜和耐用烘箱,并通过铂电阻(Pt100)传感器体统高水平的稳定性。其他特征为:

? Low noise (zero crossing) power switching to eliminate interference with otherlaboratory equipment (computers etc.)

低噪音(零)电源开关以消除其他试样设备的干扰(计算机等)

? Direct selection of program temperature set point

直接选取温度设置点程序

? Display of actual sample temperature to 0.1 °C (can be calibrated to ensure precision).

显示样品温度精确到0.1 °C(可以被校准以确保精度)

? Long term stability

长期稳定性

Although not commercially available, the arrangement presented in Figure D1 can be readily assembled. This module can be applied to a variety of temperature control applications and can serve as a temperature monitor without the using the control function

尽管没有商业可用,图D1呈现的布置可以容易地被装备。该模具可以用在不同温控应用并在不使用控制功能时服务于温度监测。

PT100 温度传感器

180.0 温度控制器

热板

修改记录(略)(指文件本身更改记录—译者注)

互换性与技术测量试题及答案

互换性与测量技术基础复习与练习 第二部分综合练习 一、判断题 1.(T )为使零件的几何参数具有互换性,必须把零件的加工误差控制在给定的范围内。 2.( F )公差是零件尺寸允许的最大偏差。 3.( F )从制造角度讲,基孔制的特点就是先加工孔,基轴制的特点就是先加工轴。 4.(T )Φ10E7、Φ10E8、Φ10E9三种孔的上偏差各不相同,而下偏差相同。 5.( F )有相对运动的配合应选用间隙配合,无相对运动的配合均选用过盈配合。 6.( F )若某平面的平面度误差值为0.06mm,则该平面对基准的平行度误差一定小于0.06mm。7.(T )若某平面对基准的垂直度误差为0.05mm,则该平面的平面度误差一定小于等于0.05mm.。8.( F )只要离基准轴线最远的端面圆跳动不超过公差值,则该端面的端面圆跳动一定合格。9.( F )轴上有一键槽,对称度公差为0.03mm,该键槽实际中心平面对基准轴线的最大偏离量为0.02mm,它是符合要求的。 10.(F )跳动公差带不可以综合控制被测要素的位置、方向和形状。 11.( F )某轴标注径向全跳动公差,现改用圆柱度公差标注,能达到同样技术要求。 12.( F )最大实体要求既可用于中心要素,又可用于轮廓要素。 13.( F )采用包容要求时,若零件加工后的实际尺寸在最大、最小尺寸之间,同时形状误差小于等于尺寸公差,则该零件一定合格。 14.( F )测量仪器的分度值与刻度间距相等。 15.( F )若测得某轴实际尺寸为10.005mm,并知系统误差为+0.008mm,则该尺寸的真值为10.013mm。16.(T )在相对测量中,仪器的示值范围应大于被测尺寸的公差值。 17.( F )量块按“级”使用时忽略了量块的检定误差。 18.( F )零件的尺寸公差等级越高,则该零件加工后表面粗糙度轮廓数值越小,由此可知,表面粗糙度要求很小的零件,则其尺寸公差亦必定很小。 19.(T )测量和评定表面粗糙度轮廓参数时,若两件表面的微观几何形状很均匀,则可以选取一个取样长度作为评定长度。 20.(T )平键联结中,键宽与键槽宽的配合采用基轴制。 21.( F )螺纹中径是指螺纹大径和小径的平均值。 22.( F )对于普通螺纹,所谓中径合格,就是指单一中径、牙侧角和螺距都是合格的。 23.( F )螺纹的单一中径不超出中径公差带,则该螺纹的中径一定合格。 24.(T )内螺纹的作用中径不大于其单一中径。 25.(T )中径和顶径公差带不相同的两种螺纹,螺纹精度等级却可能相同。 26.(T )圆锥配合的松紧取决于内、外圆锥的轴向相对位置。 27.(T )测量内圆锥使用塞规,而测量外圆锥使用环规。 28.( F )齿轮传动的振动和噪声是由于齿轮传递运动的不准确性引起的。 29.(T )在齿轮的加工误差中,影响齿轮副侧隙的误差主要是齿厚偏差和公法线平均长度偏差。30.(T )圆柱齿轮根据不同的传动要求,同一齿轮的三项精度要求,可取相同的精度等级,也可以取不同的精度等级相组合。 二、选择题 1.保证互换性生产的基础是()。 A.标准化B.生产现代化C.大批量生产D.协作化生产 2.基本偏差代号f的基本偏差是()。 A.ES B.EI C.es D.ei 3.30g6与30g7两者的区别在于()。

新国标GBT 34657交流充电桩互操作性测试方案解读

新国标GB/T 34657交流充电桩互操作性测试方案解读 《GB/T 34657.1-2017 电动汽车传导充电互操作性测试规范第1部分:供电设备》、《GB/T 34657.2-2017 电动汽车传导充电互操作性测试规范第2部分:车辆》已经于2018年5月份正式实施,电动汽车及充电桩行业具备一个详细的测试标准,在新测试标准的监督下电动汽车与充电桩的兼容匹配性将会大大提高。本文将为解读新国标GB/T 34657.1交流桩互操作性测试。 一、测试项目 《GB/T 34657.1-2017 电动汽车传导充电互操作性测试规范第1部分:供电设备》规定的交流充电桩互操作测试项目 二、测试系统组成 标准中提及交流充电桩互操作测试系统的组成,如图所示。主要包括车辆控制器模拟盒(测试交流充电桩的充电控制过程、异常充电状态以及连接控制时序等)、交流电源(模拟电网供电特性)、负载(模拟电池消耗充电桩的输出能量)、测试仪器(测量充电桩的电气特性及控制信号状态等)、主控机(控制车辆控制器模拟盒模拟充电过程的不同状态、采集记录测试仪器的测量数据生成测试报告)。这几部分对充电桩进行有序的联动测试可以大大提高测试效率。

图1、交流充电桩交流充电检测系统 群菱能源新国标的技术要求推出便携式交流充电桩互操作测试设备ACTE-2240H ,设备采用6U标准模块化设计,可安装于便携箱,现场测试方便快捷;满足GB/T 34657.1-2017 《电动汽车传导充电互操作性测试规范第1部分:供电设备》标准要求,包括连接确认测试、充电准备就绪测试、启动及充电阶段测试、正常充电结束测试、充电连接控制时序测试、CC断线测试等交流充电桩互操作测试内容;设备可以实现充电电压、电流、功率、CC阻值、充电状态实时监控。 图2、ACTE-2240H 交流充电桩交流充电测试系统结构 ACTE-2240H 交流充电桩互操作测试设备带有63A标准交流充电枪插座,插座定义满足GB/T 20234.3-2015标准规定的要求;设备带有具备S2和不具备S2两种车辆状态模拟功能;设备带有L1、N、PE、CP、CC各个触点回路通断开关以及CC接地短路开关可实现各路通断、短路故障状态仿真模拟功能;设备带有电动汽车车辆交流充电控制导引仿真电路,具有R2、R3等效电阻仿真功能。

浙江省宁波市2020届高三适应性考试(二模)技术试题 (含答案)

宁波市2019学年第二学期选考适应性考试 技术试卷 第一部分信息技术(共50分) 一、选择题(本大题共12小题,每小题2分,共24分。在每小题给出的四个选项中,只有一个符合题目要求,不选、多选、错选均不得分) 1.下列说法不正确 ...的是 A.对朋友圈中的某条信息进行点赞,属于信息的个人推荐评价 B.信息是可以脱离它所反映的事物被存储、保存和传播的 C.网民通过手机扫二维码关注公众号的过程,属于信息的获取过程 D.因为信息具有共享性,所以网上论坛中的信息可随意转发 2.小李在结束一天工作后回家期间经历了下列事情: ①通过人脸识别功能登录某支付软件买了一瓶饮料 ②用手机骑行APP记录骑行路径 ③用小区门禁卡刷开了小区进出通道的小门 ④通过语音命令智能音箱打开空调并调整到适宜温度 ⑤通过微信的语音通话功能与朋友进行了通话 ⑥通过微信小程序将朋友传过来的文件照片转换成文本 上述事件中体现了人工智能技术应用的是 A.①②⑥ B.②④⑤ C.①④⑤ D.①④⑥ 3.使用UltraEdit软件观察字符内码,部分界面如图所示。 则“3*10<9错误”的内码可能是 4.使用Access软件打开数据库,部分界面如下图所示。

下列说法正确的是 A.打开的数据库文件名为“图书馆.accdb” B.删除表中当前记录,能够通过“”按钮进行恢复 C.为了存储超过300字的书籍简介,应将“简介”字段的数据类型设置为“备注” D.当前数据表中已有一个名为“ID”的字段,则其他数据表不能含有名称是“ID”的字段 5.用Photoshop软件编辑某PSD文件的界面如图所示,下列说法正确的是 A.“春游踏青”图层的图层样式效果均可视 B.使用“仿制图章”工具可在“燕子”图层仿制多只燕子 C.不可对直接“背景”图层设置滤镜效果,但能够设置不透明度 D.将“背景”图层设置为不可视后,保存成的JPEG格式图像背景透明 6.一幅未经压缩的1024*768像素、24位色的BMP图像,存储为JPEG格式后,其存储容量为230KB,则该JPEG图像的压缩比约为 A.5:1 B.10:1 C.30:1 D.36:1 7.已知s=6.1,t=16,m=-6,下列表达式的值为True的是 A.s

互换性与测量技术试卷及答案

注:学生不得在草稿纸上答题,答题不得超出框体 。

注:学生不得在草稿纸上答题,答题不得超出框体 。1.矩形花键的定心方式有哪几种?国标规定采用何种方式?为什么?(8分) 答: 2.表面粗糙度的评定参数可以分为几类?列举出至少4 它们各自的适用场合。(7分) 答: 3.评定齿轮传递运动准确性和评定齿轮传动平稳性指标都有哪些?(10分) 答: 四.标注与改错题(共18分,按具体要求答题) (8分) 圆柱面对Φ40H7孔轴线的径向圆跳动公差为0.025mm。 孔圆柱度公差为0.007mm。 Φ40H7孔轴线的圆跳动公差为0.012mm。 Φ40H7孔轴线的对称度公差为0.02mm。 。(10 分)

注 : 学 生 不 得 在 草 稿 纸 上 答 题 , 答 题 不 得 超 出 框 体 。 解: 五.综合计算题(共25分,要求步骤清晰、计算完整、结论明确) 0.039 50 φ+mm,轴0.034 0.009 50 φ+ + mm,求 max X、 max Y及T f,并 (10分) 轴孔配合,要求极限间隙为25-66,试确定配合制,孔轴公差等级及

注:学生不得在草稿纸上答题,答题不得超出框体 。

注:学生不得在草稿纸上答题,答题不得超出框体 。 答:表面粗糙度的评定参数可以分为4类。(1分) (1)轮廓的算术平均偏差Ra (1分) (2)轮廓的最大高度Rz (1分) 凡是有表面粗糙度要求的表面,必须选用一个幅度参数,一般情况下可以从 Rz中任选一个。 在常用值范围内(Ra为0.025~6.3m μ)优先选用参数Ra, 光滑时,即表面粗糙度要求特别低或特别高(100m μ>Ra>6.3m μ或0.008m μ <0.025m μ)的时候,多选用参数Rz; (3)轮廓单元的平均宽度Rs m (2分) 例如,光泽表面、涂镀性、抗腐蚀性、减小流体流动摩擦阻力(如车身迎风面) 性等,就需要控制Rs m(轮廓单元平均宽度)数值。 (4)轮廓支承长度率Rm r(c)(2分) 对表面的支撑刚度和耐磨性有较高要求时(如轴瓦、轴承、量具等) Rm r(c)来进一步控制加工表面的特征质量。 3.评定齿轮传递运动准确性和评定齿轮传动平稳性指标都有哪些?(10 答 偏差、径向跳动、径向综合总偏差。(每个1分) 差、基圆齿距偏差、单个齿距偏差。(每个1分) 四.标注与改错题(共20分,按具体要求答题) 1.试将下列各项几何公差要求标注在所示的图上。(8分) 2分 A,2分,同轴度指引线对齐尺寸线,1分,加φ1 1分,去掉φ1分;AB字母对准尺寸线各1分; 1分,基准加B1分。 25分,要求步骤清晰、计算完整、结论明确) =D max-d min=50.039-50.009=+0.030mm (2分)

2017年10浙江省十校联盟适应性考试技术试题(通用技术部分)

第二部分:通用技术(共50分) 一、选择题(本大题共13小题,每小题2分,共26分。每小题列出的四个备选项中只有一个是符合题目要求的,不选、多选、错选均不得分) 1、浙江省电子支付技术发展迅速,电子支付普及率居全国前列。下列关于电子支付技术的 说法不恰当的是 A.电子支付免去了付款中的找零流程,提高了支付效率,体现了技木具有发展人的作用 B.无纸化的电子货币减少纸张消耗,体现了技术发展的同时注重环境保护 C.电子支付带动了相关互联网产业发展,体现了技术具有促进社会生产发展的作用 D.电子支付技术涉及信息加密、通信等相关技术,体现了技术的综合性 2、如图所示是一款可折叠手摇三轮车,收纳时占空间较少,摇把高低可调,适合不同身高的人使用,扶手可抬起,方伸人上下车,产品设计时不仅考虑了可装配性,也考虑了连接的可拆卸性,方便维修与回收,以节约资源,以下说法中不正确的是

A.扶了可抬起,方便人上下车,体现了人机关系的高效目标 B.摇把高低可调,适合不同身高的人使用,体现了人机关系的安全目标 C.可折叠设计,便于运输与收纳,体现了设计的经济原则 D.考虑连接的可拆卸性,方便维修与回收,体了设计的可持续发展原则 3、如图所示的Z字型坐凳,凳面与底面仅由一斜板连接。为了保证连接处的结构强度,凳面与斜板间 较合理的连接方式是

4、如图所示是小王在通用技术 课上设计的零件图,以下关于 尺寸标注的说法中,正确的是 A.错误标注3处 B.20标的是圆孔 C.尺寸漏标1处 D.尺寸多标1处 5、在通用技术实践课上,用矩形钢制作如图所示的小工艺挂件,以下说法中正确的是 A.锉刀中嵌入的钢屑用毛刷顺着锉纹清理 B.挂件的外部弧形用台钻直接钻出 C.划线时,要用到划针与划规 D.锯割时,工件应夹持在台虎钳的右侧

互换性与测量技术基础第四版答案

《互换性与测量技术基础》习题参考解答(第3版) 第二章 光滑圆柱体结合的公差与配合 1. 孔或轴 最大极限尺寸 最小极限尺寸 上偏差 下偏差 公差 尺寸标注 孔: Φ10 9.985 9.970 -0.015 -0.030 0.015 Φ10015 .0030.0-- 孔: Φ18 18.017 18 +0.017 0 0.017 Φ18017.00 + 孔: Φ30 30.012 29.991 +0.012 -0.009 0.021 Φ30012.0009.0+- 轴: Φ40 39.95 39.888 -0.050 -0.112 0.062 Φ40050.0112.0-- 轴: Φ60 60.041 60.011 +0.041 +0.011 0.030 Φ60041.0011.0++ 轴: Φ85 85 84.978 -0.022 0.022 Φ850 022.0- 2. 1) X max = 0.033- (-0.098) = 0.131mm X min = 0 - (-0.065) = 0.065mm T f = | 0.131-0.065 | = 0.066mm 2) Y max = 0 – 0.060 = -0.060mm Y min = 0.030 – 0.041 = -0.011mm T f = | -0.060+0.011 | = 0.049mm 3) X max = 0.007- (-0.016) =0.023mm Y max = -0.018 – 0 = -0.018mm T f = | 0.023 – (-0.018)| = 0.041mm 4) X max = 0.039 - 0.002 = 0.037mm Y max = 0 – 0.027 = -0.027mm T f =|0.037 – (-0.027)| = 0.064mm 5) X max = 0.074 – (-0.140) = 0.214mm X min = 0 - (-0.030) = +0.030mm T f =| 0.214 – 0.030 | = 0.184mm 6) X max =0.009 – (-0.019) = 0.028mm Y max = -0.021 – 0 = -0.021mm T f =| 0.028 – (-0.021) | = 0.049mm 3. (1) Φ50)(7f ) (8H 025 .0050.0039.00--+ Xmax = 0.089mm Xmin = 0.025mm 基孔制、间隙配合 (2)Φ80)(10h )(10G 0 120.0130.0010.0-++ Xmax = 0.250mm Xmin = 0.010mm 基轴制、间隙配合 (3)Φ30)(6h )(7K 0013.0006 .0015.0-+- X max = 0.019mm Y max = -0.015mm 基轴制、过渡配合 (4)Φ140) (8r ) (8H 126 .0063.0063.00+++ Y max = -0.126mm Y min = 0mm 基孔制、过盈配合 第2题

CMTBF信赖性测试评估准则

光宝科技股份有限公司 文件名称:信赖性测试评估准则 信赖性测试评估准则 ( Reliability Review Guideline ) 1 目的: 1.1 为确保产品设计的信赖性,以及加强产品在市场之竞争力,建立〝零件额定使用率〞 ( Component Stress Test ) 及〝机种预估寿命〞(MTBF Prediction) 之信赖性准则, 用以为厂内设计验证之依据。 1.2 提早介入及加速产品之成熟度。 1.3 避免上市后之风险。 2. 范围: 凡是本公司电源事业部所开发之产品均适用之。 3. 权责: 3.1 零件额定使用率 ( Component Stress Test ) 及机种预估寿命 (MTBF Prediction) 由信赖性 工程师负责测试,Component Stress De-rating 之定义由设计部及信赖性共同定义。 3.2 测试样品由设计工程师负责提供,且须经过Bench Test 测试,或有机种之验证报告。 3.3 信赖性完成之测试报告须会签设计部及其部门主管认可后,才可对外发行。 3.4 信赖性完成之测试报告文件,均须透过DOC 才能对外发行。 4. 参考标准: 4.1. 零件额定使用率参考准则 : ISO 9001 NPS-MD-P-013。 4.2. 机种预估寿命( MTBF )参考准则: MIL-STD-217F, Bellcore TR332 ISSUE 6。 5. 定义: MTBF ( Mean Time Between Failure ) :平均间隔失效时间。 MTBF = 1/p λ(p λFAILURE RATE)610* HOURS 6. 作业流程图: 6.1 信赖性测试评估作业流程图如 附件1 7. 作业内容: 7.1 新产品导入会议 ( Kickoff Meeting ): 7.1.1 新机种由业务主导之新产品会议中决定: 7.1.1.1. 决定样品 ( SAMPLE ) 及其它资料日期. 7.1.1.2. BLUE BOOK 发出之日期. 7.1.1.3. 信赖性工程师应于EVT 阶段开始执行评估, 且必须于Pilot run PCB 修改定案之前 完成零件额定使用率之测试与评估, 以符合量产及客户的需求。

职业适应性测试试卷及参考答案(最新)

2019年职业适应性测试试卷及参考答案 一、选择题 1、王丽安排早上、中午、晚上各1个小时的时间学习房地产中介理论。一段时间后,他发现早上、晚上的记忆特好,很容易掌握,但中午的学习效率特差。于是他调整了学习计划,取消了中午的学习安排,扩大了早晚的学习时间。王丽的事情主要说明了(B)时候需要做自我形象检查。 A、在学习过程中要善于“算计时间” B、在学习过程中要善用生物节律 C、在学习过程中要善于调整计划 D、在学习过程中要善于突破“循环圈” 2、多媒体学习工具的利用是传统学习方式的一种补充,他能更好的解决在传统学习中不能或难以 解决的问题。那么人类记住的信息主要是(D)部分。 A、读到的 B、听到的 C、看到的 D、交流的 3、人讲举一反三、触类旁通,意思是掌握某种知识后,能把这些知识应用于相似的或有联系的工 作岗位及工作任务中去,实现学习的迁移。当然,迁移有正迁移和负迁移之分,下面哪些现象不属于正迁移?(B) A、学习钢琴的人再来学习小提琴 B、学习汉语拼音的人再去学习英语 C、学习数字的人再去学习经济学 D、学习英语的人再来学习法语 4、孔子说,“吾日三省吾身”。“省”就是反省、评估自己。自我学习也需要不断的反省,不断的自我评估。一般而言,自我评估不包括(A)。 A、学习时间的评估 B、学习内容与效果的评估 C、实现目标途径的评估 D、学习方法的评估 5、第一次的月考结束了,老师把各科的试卷都发下来了,面对这些试卷,你应该(CD) A、看见这么低的分数,心里气馁,干脆就不学了。 B、需要好长一段时间来平静下。 C、在老师讲解试题的时候,认真听老师分析。 D、找各科老师,请老师帮着分析成绩,制定复习方案。 6、下列表示学习的成语是(B) ①循序渐进②乐学勤思③废寝忘食④闻鸡起舞⑤不耻下问⑥目不转睛 A、②③⑤ B、①②③④⑤ C、①②③⑤ D、②③⑤⑥ 7、毕业后,你有一个生产项目在脑中成形,此项目要进行实施,你首先要做:(A) A、市场调研 B、生产 C、小批量生产 D、试点试销 8、在北京残奥会上,我们看到了篮球运动员们借助特制的篮球轮椅进行比赛。1为普通轮椅,2为

《互换性与测量技术》试卷及答案(考研必备)

08春期《互换性与测量技术基础》课程期末复习指导 重庆远程导学中心理工导学部 修订时间2008年6月 第一部份课程考核说明 1.考核目的 考核学生对互换性与测量技术基础的基本理论、基本计算方法的理解和实际的计算分析能力。 2.考核方式 闭卷,笔试,90分钟 3.命题依据 本课程的命题依据是《互换性与测量技术基础》课程的教学大纲、教材、实施意见。 4.考试要求 本课程的考试重点包括基本知识和应用能力两个方面,主要考核学生对互换性与测量技术基础的基本理论、基本计算方法的理解和对实际问题的计算分析能力。 5.考题类型及比重 考题类型及分数比重大致为:选择题(30%);填空题(30%);判断题(10%);计算题(20%),标注题(10%)。 6、适用范围、教材 本课程期末复习指导适用范围为成人专科机械制造专业的必修课程。 考试命题的主教材:,《互换性原理与测量技术基础》,刘巽尔主编,中央广播电视大学出版社出版。 第二部份期末复习重点范围 第一章:绪论 一、重点名词 完全互换不完全互换 二、重点掌握/熟练掌握 1.应从装配这程中三个不同阶段(装配前、装配时、装配后)的要求全面理解换性的含义。 三、一般掌握 1.我国标准化和计量测试工作的概况可作一般了解。 第二章:基本术语和定义 一、重点名词 孔轴 二、重点掌握/熟练掌握 1.掌握孔和轴的概念; 2.掌握有关“尺寸”的素语; 3.掌握有关“偏差”的术语; 4.掌握有关“公差”的概念,分清它与极限偏的区别与联系。 5.掌握公差带(尺寸公差带)的概念,熟悉掌握公差带的画法;

6.掌握有关“配合”的概念;⑺孔、轴的尺寸合格与结合的合用是两个不同的概念,应注意区分。 三、一般掌握 无 第三章:测量技术基础 一、重点名词 测量误差随机误差 二、重点掌握/熟练掌握 1.掌握量块的特性及量块的组合方法; 2.掌握各种测量分类法的特点; 3.掌握计量器具的分类及其技术性能指标。 4.掌握测量误差的含义及其表示法; 5.掌握测量误差的基本类型及其处理原则; 6.掌握随机误差的概念及测量结果的表示法; 7.掌握测量误差的合成。 三、一般掌握 1.掌握有关测量的概念; 2.一般了解尺寸的传递系统; 第四章:公差与互换 一、重点名词 公差配合 二、重点掌握/熟练掌握 1.掌握公差与配合国家标准的主要内容; 2.掌握公差与配合国家标准的应用; 3.掌握光滑极限量规; 4.掌握验收极限的规定方法和计算器具的选择方法; 5.掌握滚动轴承的公差与配合标准的基本内容。 三、一般掌握 无 第五章:表面粗糙度 一、重点名词 表面粗糙度 二、重点掌握/熟练掌握 1.掌握表面粗糙度的概念; 2.掌握表面粗糙度的评定参数; 3.掌握表面粗糙度的特征代(符)号及其标注方法。 三、一般掌握 无 第六章:形状和位置公差 一、重点名词 形位公差位置公差公差原则 二、重点掌握/熟练掌握 1.掌握形位公差; 2.掌握位置公差;

新国标GBT34657交流充电桩互操作性测试方案解读

新国标GB/T 34657 交流充电桩互操作性测试方案解读 《 GB/T 34657.1-2017 电动汽车传导充电互操作性测试规范第 1 部分:供电设备》、《 GB/T 34657.2-2017 电动汽车传导充电互操作性测试规范第 2 部分:车辆》已经于 2018 年 5 月份正式实施,电动汽车及充电桩行业具备一个详细的测试标准,在新测试标准的监督下电动汽车与充电桩的兼容匹配性将会大大提高。本文将为解读新国标 GB/T 34657.1 交流桩互操作性测试。 一、测试项目 《 GB/T 34657.1-2017 电动汽车传导充电互操作性测试规范第 1 部分:供电设备》规定的交流充电桩互操作测试项目 二、测试系统组成 标准中提及交流充电桩互操作测试系统的组成,如图所示。主要包括车辆控制器模拟盒(测试交流充电桩的充电控制过程、异常充电状态以及连接控制时序等)、交流电源(模拟电网供电特性)、负载(模拟电池消耗充电桩的输出能量)、测试仪器(测量充电桩的电气特性及控制信号状态等)、主控机(控制车辆控制器模拟盒模拟充电过程的不同状态、采集记录测试仪器的测量数据生成测试报告)。这几部分对充电桩进行有序的联动测试可以大大提高测试效率。

图 1 、交流充电桩交流充电检测系统 群菱能源新国标的技术要求推出便携式 交流充 电桩互操作测试设备 ACTE-2240H ,设备采用 6U 标准 模块化设计,可安装于便携箱,现场测试方便快捷;满足 GB/T 34657.1-2017 《电动汽车传导充电互操作 性测试规范第 1 部分:供电设备》标准要求,包括连接确认测试、充电准备就绪测试、启动及充电阶段测试、 正常充电结束测试、 充电连接控制时序测试、 CC 断线测试等交流充电桩互操作测试内容;设备可以实现充电 电压、电流、功率、 CC 阻值、充电状态实时监控。 图 2、 ACTE-2240H 交流充电桩交流充电测试系统结构 ACTE-2240H 交流充电桩互操作测试设备带有 63A 标准交流充电枪插座,插座定义满足 GB/T 20234.3-2015 标准规定的要求;设备带有具备 S2 和不具备 S2 两种车辆状态模拟功能;设备带有 L1、N 、 PE 、 CP 、CC 各个触点回路通断开关以及 CC 接地短路开关可实现各路通断、短路故障状态仿真模拟功能; 设备带有电动汽车车 辆交流充电控制导引仿真电路,具有 R2、R3 等效电阻仿真功能。

互换性与测量技术课程

《互换性与测量技术》课程 实 验 指 导 书 2008年7月

目录 实验一用万能工具显微镜测量轴径 (2) 实验二用立式光学计测量轴径 (9)

实验一用万能工具显微镜测量轴径 一、实验目的及要求 1.了解万能工具显微镜的测量原理。 2.熟悉用万能工具显微镜测量外径的方法。 3.加深理解计量器具与测量方法的常用术语。 二、实验仪器 19JC数字式万能工具显微镜一台、被测轴。 三、实验原理和步骤 1、19JC数字式万能工具显微镜简介 (1)仪器用途 仪器具有较高的测量精度,特别适用于长度和角度的精密测量,並配备了全套附件,使其使用范围得到充分的扩大。 仪器可用影像法、轴切法或接触法按直角坐标或极坐标对机械工具和零部件的长度、角度和形状、位置关系等进行精密测量。 主要的测量对象有:刀具、量具、模具、样板、螺纹和齿轮等工件。 可测量外螺纹(螺纹塞规、丝杆和蜗杆等)的中径、大径、小径、螺距、牙型角;齿轮滚刀的导程、齿形和牙型角;电路板、钻模或孔板上孔的位置度、键槽的对称度等形位误差等。 (2)仪器特点: 主显微镜配有多种目镜和物镜、视场宽、成像清晰。 采用光电数显技术,精密光栅尺作为测量元件,测量长度以数字显示,直观、方便。 主显微镜可左右偏摆,特别适于测螺旋零件。

以非接触测量为基本方法,透、反射照明,内、外轮廓可测。 附件多,使用面广。 (3)技术规格: ①测量范围与分度值 X-Y向坐标:测量范围: X–Y向:200×100毫米 分度值(数显读数):0.0005毫米 瞄准显微镜:升降行程: 120毫米 立臂倾斜范围:左右各15度 分度值: 10分 照明光栏调节范围:Φ3~Φ32毫米 分度值:1毫米 测角目镜:角度测量范围: 360度 分度值: 1分 轮廓目镜:角度测量范围:±7度 分度值: 1分 圆弧分划板:曲率半径R:0.1~100毫米 螺纹分划板:普通螺纹螺距t:0.25 - 6 毫米 梯形螺纹螺距t:2 - 20 毫米光学分度台:测量范围: 360度 分度值: 10秒(投影读数) 玻璃台面直径:Φ106毫米 光学分度头:测量范围: 360度 分度值: 1分 光学定位器:测头直径:Φ3±0.1毫米 测头直径的检定极限误差不大于0.5微米 测量力: 0.098±0.0196牛顿

2019年12月浙江省慈溪市2020届高三上学期12月适应性考试技术试卷及答案

绝密★考试结束前 2019年12月浙江省慈溪市2020届高三上学期12月适应性考试 技术试卷 ★祝考试顺利★ 第一部分信息技术(共50分) 一、选择题(本大题共12小题,每小题2分,共24分。在每小题给出的四个选项中,只有一个符合题目要求,不选、多选、错选均不得分) 1.下列有关信息的说法正确的是 A.信息技术教材是信息的载体,教材上的文字、图像是信息 B.通过元搜索引擎来检索信息,是在因特网上检索信息的一种途径 C.将自己个人基本信息存储为二维码的过程属于信息的采集 D.信息不可以脱离它所反映的事物被存储、保存和传播 2.下列关于浏览器与网页的说法正确的是 A.浏览器与Web服务器之间通过HTTP协议交互数据 B.将网页以“Web档案,单个文件(*.mht)”类型保存,其中的图片未被保存 C.清除浏览器历史记录,收藏夹中的网址也会被同时清空 D.浏览器的功能是既能解释执行网页代码,也能对网页进行编辑 3.下列应用中,体现了人工智能技术的有 ①通过人脸识别登录某APP ②微信好友间通过语音通话功能进行实时聊天 ③通过在线翻译网站把一段中文翻译成英文 ④使用扫描仪扫描答题纸获取数字化的图像 ⑤通过OCR软件识别杂志图片中的文字 人①②⑤ B.①③⑤ C.①③④ D.②③⑤ 4.下列关于Access数据表的说法正确的是 A.同一数据表中各记录的字段数是相同的 B.数据表中有记录时,该表的字段类型无法修改 C.将数据表中类型为“是/否”的字段改为“文本”类型后字段的值会变为“Truc”

或“False” D.Access数据表中的记录可在设计视图中添加、删除和修改 5.使用GoldWave软件打开某音频文件,选中其中一段音频后的部分界面如图所示。下列说法正确的是 A.该音频每秒钟采样1411k次,保存为MP3可以实现声音的有损压缩 B.单击“删除”按钮后,音频的时长变为2秒 C.执行“更改音量”命令将音量提升后,采样频率同步变大 D.执行“静音”命令后直接保存,音频文件的大小变为原来的2/3 6.使用ACDSee软件将“zsl.bmp”文件进行另存为操作,得到的图像文件属性如图所示,则该操作采用的压缩方式及压缩比分别为 A.无损压缩4.9:1 B.无损压缩39.3:1 C.有损压缩4.9:1 D.有损压缩39.3:1 7.VB表达式45/5Mod7\3+6的值是 A.6 B.7 C.8 D.9 8.某算法的部分流程图如图所示,执行这部分流程后,下列分析正确的是

浙江省慈溪市2020届高三12月适应性考试+技术+Word版含答案

绝密★考试结束前 2019学年第一学期12月份高三适应性考试 技术试题 第一部分信息技术(共50分) 一、选择题(本大题共12小题,每小题2分,共24分。在每小题给出的四个选项中,只有一个符合题目要求,不选、多选、错选均不得分) 1.下列有关信息的说法正确的是 A.信息技术教材是信息的载体,教材上的文字、图像是信息 B.通过元搜索引擎来检索信息,是在因特网上检索信息的一种途径 C.将自己个人基本信息存储为二维码的过程属于信息的采集 D.信息不可以脱离它所反映的事物被存储、保存和传播 2.下列关于浏览器与网页的说法正确的是 A.浏览器与Web服务器之间通过HTTP协议交互数据 B.将网页以“Web档案,单个文件(*.mht)”类型保存,其中的图片未被保存 C.清除浏览器历史记录,收藏夹中的网址也会被同时清空 D.浏览器的功能是既能解释执行网页代码,也能对网页进行编辑 3.下列应用中,体现了人工智能技术的有 ①通过人脸识别登录某APP ②微信好友间通过语音通话功能进行实时聊天 ③通过在线翻译网站把一段中文翻译成英文 ④使用扫描仪扫描答题纸获取数字化的图像 ⑤通过OCR软件识别杂志图片中的文字 人①②⑤ B.①③⑤ C.①③④ D.②③⑤ 4.下列关于Access数据表的说法正确的是 A.同一数据表中各记录的字段数是相同的 B.数据表中有记录时,该表的字段类型无法修改 C.将数据表中类型为“是/否”的字段改为“文本”类型后字段的值会变为“Truc”或“False” D.Access数据表中的记录可在设计视图中添加、删除和修改 5.使用GoldWave软件打开某音频文件,选中其中一段音频后的部分界面如图所示。下列说法正确的是

互换性与测量技术基础总复习题(答案)

1.将下列技术要求标注在图上 (1)圆锥面的圆度公差为0.01 mm,圆锥素线直线度公差为0.02 mm。 (2)圆锥轴线对φd1和φd2两圆柱面公共轴线的同轴度为0.05 mm。 (3)端面Ⅰ对φd1和φd2两圆柱面公共轴线的端面圆跳动公差为0.03 mm。 (4)φd1和φd2圆柱面的圆柱度公差分别为0.008 mm和0.006 mm。 (5)φd1和φd圆柱面的表面粗糙度R a值不允许大于0.8μrn,其余表面R a值不允许大于3.2μrn 。 2.试将下列技术要求标注在图上。 (1)2-φd轴线对其公共轴线的同轴度公差为φ0.02mm。 (2)φD轴线对2-φd公共轴线的垂直度公差为100 :0.02 mm。 (3)槽两侧面对φD轴线的对称度公差为0.04 mm。 3.将下列技术要求标注在图上 (1)左端面的平面度公差为0.01 mm,右端面对左端面的平行度公差为0.04 mm。 (2)φ70H7孔的轴线对左端面的垂直度公差为0.02mm。 (3)φ210h7轴线对φ70H7孔轴线的同轴度公差为φ0.03mm。 (4)4-φ20H8孔的轴线对左端面(第一基准)和φ70H7孔轴线的位置度公差为φ0.15mm。

4.将表面粗糙度符号标注在图上,要求 (1)用任何方法加工圆柱面φd3,R a最大允许值为3.2μm。 (2)用去除材料的方法获得孔φd1,要求R a最大允许值为3.2μm。 (3)用去除材料的方法获得表面A,要求R z最大允许值为3.2μm。 (4)其余用去除材料的方法获得表面,要求R a允许值均为25μm 。 5、试将以下要求用形位公差代号标注在图中 (1)Φd圆柱面的圆柱度公差为0.012mm; (2)右端面对Φd轴线的圆跳动公差为0.01mm; (3)Φd轴线的直线度公差为Φ0.008mm; (4)圆锥面A的圆度公差为0.006mm; (5)圆锥面A素线的直线度公差为0.005mm。 (6)Φd圆柱面的表面粗糙度R a值不允许大于1.6μrn,其余表面R a值不允许大于6.3μrn 。

一致性和互操作性仿真测试实验

南京邮电大学自动化学院 实验报告 实验名称:一致性和互操作性仿真测试实验 课程名称:网络测试技术 所在专业: 学生姓名: 班级学号: 任课教师:戴尔晗 2014 /2015 学年第二学期

实验3 一致性和互操作性仿真测试实验 3.1 实验目的 ●理解一致性实验和互操作实验的测试配置。 ●理解一致性实验和互操作实验的测试过程。 3.2 实验环境 本仿真实验的计算机来仿真一致性测试和互操作性测试,实验环境由一台计算机组成。其仿真的测试拓扑如图3.1所示。 图3.1 测试拓扑 3.3 实验内容及其规划 计算机运行从站程序和主站程序,根据从站的一致性声明,从主站程序上输入测试数据生成测试流发送给从站程序,从站接收到测试流后回应主站,由主站判断测试是否通过。 具体的测试项要包含针对读线圈的如下一致性测试:

具体的测试项还要包含针对除读线圈之外若干个功能不支持测试: 3.4 实验步骤 通常,一个完整的测试过程有以下几个阶段组成:测试环境的搭建、测试设置、测试运行、测试结果保存与分析。 1.测试环境的搭建和测试设置 运行从站程序如图3.2。 图3.2 从站运行程序图 在图3.2上修改主站IP 地址和从站的MODBUS 地址。

运行主站程序如图3.3。 图3.3 主站运行程序图 2.从站配置 从站的一致性声明的功能实现如下:

3.运行测试 (1)启动测试过程 在主站程序的发送内容内输入发送内容后,添加CRC校验,然后点击发送按钮。 a.填充位测试 b.无效线圈数量测试 c.无效线圈地址测试

d.广播模式测试 e.错误地址测试 f.校验错误测试 g.功能不支持测试1

职业适应性测试试卷及参考答案()

| 2019年职业适应性测试试卷及参考答案 一、选择题 1、王丽安排早上、中午、晚上各1个小时的时间学习房地产中介理论。一段时间后,他发现早上、晚上的记忆特好,很容易掌握,但中午的学习效率特差。于是他调整了学习计划,取消了中午的学习安排,扩大了早晚的学习时间。王丽的事情主要说明了(B)时候需要做自我形象检查。 A、在学习过程中要善于“算计时间” B、在学习过程中要善用生物节律 C、在学习过程中要善于调整计划 D、在学习过程中要善于突破“循环圈” 2、多媒体学习工具的利用是传统学习方式的一种补充,他能更好的解决在传统学习中不能或难以解决的问题。那么人类记住的信息主要是(D)部分。 A、读到的 B、听到的 C、看到的 D、交流的 3、人讲举一反三、触类旁通,意思是掌握某种知识后,能把这些知识应用于相似的或有联系的工作岗位及工作任务中去,实现学习的迁移。当然,迁移有正迁移和负迁移之分,下面哪些现象不属于正迁移(B) 《 A、学习钢琴的人再来学习小提琴 B、学习汉语拼音的人再去学习英语 C、学习数字的人再去学习经济学 D、学习英语的人再来学习法语 4、孔子说,“吾日三省吾身”。“省”就是反省、评估自己。自我学习也需要不断的反省,不断的自我评估。一般而言,自我评估不包括(A)。 A、学习时间的评估 B、学习内容与效果的评估 C、实现目标途径的评估 D、学习方法的评估 5、第一次的月考结束了,老师把各科的试卷都发下来了,面对这些试卷,你应该(CD) A、看见这么低的分数,心里气馁,干脆就不学了。 B、需要好长一段时间来平静下。 C、在老师讲解试题的时候,认真听老师分析。 … D、找各科老师,请老师帮着分析成绩,制定复习方案。 6、下列表示学习的成语是(B) ①循序渐进②乐学勤思③废寝忘食④闻鸡起舞⑤不耻下问⑥目不转

互换性与测量技术复习提纲(含答案)

互换性与测量技术复习提纲 (含答案) -标准化文件发布号:(9456-EUATWK-MWUB-WUNN-INNUL-DDQTY-KII

《互换性与测量技术》复习提纲 (*仅供参考,具体以课本为准) 1、何谓互换性完全互换性与不完全互换性有何区别 答:互换性是指某一产品(包括零件、部件、构件)与另一产品在尺寸、功能上能够彼此互相替换的性能。 完全互换性与不完全互换性的区别为:当同种零、部件加工好以后,可完全互换性的产品不需经任何挑选、调整或修配等辅助处理,便可顺利装配,并在功能上达到使用性能要求,而不完全互换性的产品在装配前需经任何挑选、分组、调整或修配等辅助处理,才可顺利装配,在功能上才能达到使用性能要求。 2、何谓偏差实际偏差与极限偏差有何区别 答:偏差是指某一尺寸(实际尺寸、极限尺寸等)减去其基本尺寸所得的代数差称为偏差。 实际偏差与极限偏差的区别为:实际偏差是由实际尺寸减去其基本尺寸所得的代数差,而极限偏差是由极限尺寸减去其基本尺寸所得的代数差。 3、解释下列名词术语:尺寸公差、配合公差、实际尺寸、极限尺寸、作用尺寸、实体尺寸、基本偏差、极限偏差、实际偏差 答:尺寸公差:最大极限尺寸减去最小极限尺寸,或上偏差减去下偏差所得的代数差,是一个没有符号的绝对值。 配合公差:组成配合的孔、轴公差之和叫配合公差。 实际尺寸:通过测量获得的某一孔、轴的尺寸。 极限尺寸:一个孔或轴允许的尺寸的两个极端。 作用尺寸:在被测要素的给定长度上,与实际内、外表面体外相接或内相接的最大或最小理想面的宽度或直径。 实体尺寸:在孔或轴具有允许的材料量为最多或最少时的状态下所获得的尺寸。 基本偏差:在国家标准极限与配合制中,确定公差带相对于零线位置的那个极限的偏差。 极限偏差:由极限尺寸减去其基本尺寸所得的代数差。 实际偏差:由实际尺寸减去其基本尺寸所得的代数差。 5、何谓配合配合种类有几种其特征如何 答:配合是指基本尺寸相同的互相结合的孔和轴公差带之间的关系。配合有3中,分别为(1)间隙配合,其特征为孔的公差带完全在轴的公差带之上;(2)过盈配合,其特征为孔的公差带完全在轴的公差带之下;(3)过渡配合,其特征为孔的公差带与轴的公差带相互交叠。

互换性与测量技术试卷及答案

第三部分综合练习题 一、填空题 1.公差标准是对几何量误差的限制性措施,采用相应的技术措施是贯彻公差与配合制的技术保证。 2.轴φ50js8,其上偏差为+0.019 mm,下偏差为 -0.019 mm。3.由于径向全跳动误差包括了圆柱度误差和同轴度误差,当径向全跳动误差不大于给定的圆柱度公差值时,可以肯定圆柱度误差不会超差。 4.径向圆跳动公差带与圆度公差带在形状方面相同,但前者公差带圆心的位置是 固定的而后者公差带圆心的位置是浮动的。 5.φ30 +0.021 0mm的孔与φ30-0.007 -0.020mm的轴配合,属于基孔制间隙配合。 6.φ50mm的基孔制孔、轴配合,已知其最小间隙为0.05,则轴的上偏差是-0.05。 7.当所有的减环都是最大极限尺寸而所有的减环都是最小极限尺寸时,封闭环必为最大极限尺寸。 8.孔、轴的ES<ei的配合属于过盈配合,EI>es的配合属于间隙配合。 9.某轴尺寸为Φ10-0.018 -0.028 mm,被测要素给定的尺寸公差和形位公差采用最小实体要求,则垂直度公差是在被测要素为最小实体状态时给定的。当轴实际尺寸为Φ9.972 mm是,允许的垂直度误差达最大,可达0.02 mm。 10.孔、轴配合的最大过盈为-60μm,配合公差为40μm,可以判断该配合属于过渡配合。 11.在产品设计中,尺寸链计算是根据机器的精度要求,合理地确定有关尺寸的公差和极限偏差。 12.选择基准制时,应优先选用基孔制原因是加工孔比加工轴要困难,所用刀具量具尺寸规格也多,成本大。 13.配合公差是指允许间隙或过盈的变动量,它表示配合精度的高低。 14.国家标准中规定表面粗糙度的主要评定参数有Re 、 Ry 、 Rz 三项。 15. 含义是给定方向上元素相对基准元素A的 垂直度公差是Φ0.1,且遵循最小实体要求。 16.φ45+0.005 0mm孔的基本偏差数值为 0,φ50-0.050 -0.112轴的基本偏差数值为 -0.050 mm。 17.完全互换是指零部件在装配或换前,不做任何的选择;装配时不做调整或修配;装配后能满足预定的使用性能要求。。

互换性与测量技术基础简答题

1.什么叫齿轮累计总偏差,反映什么精度指标,切向综合误差-- 答:齿距累积总偏差:在分度圆上,任意两个同侧齿面间的实际弧长与公称弧长的最大差值,即最大齿距积累基本偏差与最小齿距积累基本偏差的代数,在分度圆上,任意k 个齿距间的实际弧长与公称弧长的最大差值,反映齿轮传送准确性。 2.测量误差特性分哪几类?测量实质是什么?一个完整的测量包括那几个要素?量块的作用,等级和种类? 答:(1)系统误差:常值系统误差,变值系统误差(2)随机误差(3)粗大误差实质是将被测几何量与作为计量单位的标准进行比较,从而确定被测几何量是计量单位的倍数或分数的过程。要素包括测量对象、计量单位、测量方法和测量精度。量块作用:(1)作为长度基准的传递媒介(2)检定和校正测量工具和量仪(3)相对测量是来调整量具或量仪的零位(4)用于精密测量,精密划线和精密机床的调整。分级:安制造精度分: 0.1.2.3,k级为最高,k级为标准级。按鉴定精度分5等:1,2,3,4,5,等,1最高5最低 3.滚动轴承内径公差带分布有什么特点,为什么这么分布?精度等级包括那些?哪些应用最广?内圈与轴,外圈与孔用什么配制? 答:滚动轴承内圈内径公差带是基孔制,因为轴承是标准件2,4,5,6,0精度由高到低,0级应用最广,(旧国标B,C,D,E,G)基孔制,基轴制 4.表面粗糙度对使用性能的影响 答:(1)影响零件的耐磨性(2)影响零件的密封性(3)影响零件的疲劳强度(4)影响零件的抗腐蚀性(5)影响配合性质的稳定性 5.螺纹的标注,螺纹参数有哪些?主要是谁?精度包括那些?作用中经是? 答:大径,小径,中径,线性,螺距,导程,螺纹升角,牙型角,接触高度,主要中径,牙型半角,螺距。精度等级分为Ⅰ,Ⅱ,Ⅲ级作用中经:螺纹旋合时实际起作用的中径 6.尺寸链,增环,减环,封闭环定义 答:尺寸链:在零件的加工或机器的装配过程中,由一组彼此相互联系的尺寸形成封闭尺寸组,其中某一尺寸的精度受其他所有尺寸精度的影响,叫尺寸链增环:与封闭环同向变动的组成环减环:。。。反向。。。封闭环:加工或装配过程中最后自然形成的那个尺寸7.互换性,配合,基孔制,基轴制,作用偏差,公差 答:零部件所具有的不经任意挑选或修配便能在同规格范围内互相替换的特性配合:基本尺寸相同的,互相结合的孔和轴公差带之间的关系基孔制:基本偏差为一定的孔的公差带,与不同的基本偏差的轴的公差形成各种配合的一种制度(EI=0)公差:允许尺寸的变动量

相关主题
文本预览
相关文档 最新文档