Procedure created on: 11/8/04 19:35
If you find any errors in this procedure or have comments regarding the generator, please send email to CLARiiONProcedureGenerator@https://www.doczj.com/doc/021807131.html,. Be sure to reference any modules by the correct filename (located to the right of the module title).
?Environment: Access Logix
?Management Software: Navisphere 6.x (pre-installed)
?Laptop Operating System: Windows 2000
?Laptop dial-up networking instructions: No
?Manage a Legacy Array with Navisphere 6.x on the Same LAN: No
?Hot Spare: No
?Host 1: HP-UX
? Boot Device in Server
? Number of HBAs: Multiple
? Failover Type: PowerPath
?Layered Applications:
?CLARalert already installed
?EMC Clarify Database User: No
number on the right and click.
Denotes a checkpoint
Verify the customer has completed the following for HP-UX PowerPath inpwp350 (3)
?Install Navisphere Agent and CLI on an HP-UX server incli050 (3)
Verify connection between SP Agent and host system cncli010 (7)
?Modify the Host Agent configuration file for an HP-UX host cncli130 (7)
?Install PowerPath on an HP-UX host inpwp360 (8)
?Cable the HBAs to the SP ports on the array inhba430 (10)
Verify the host is connected to the LAN cnlan010 (11)
Service providers begin here to continue the installation procedure inpwp110 (11)
?Install the hardware in a non-EMC rack instr050 (11)
?Set up a CX400 disk enclosure incx4010 (12)
?Initialize a CX-Series system with a Windows 2000 laptop (Navi 6.x) incx6020 (14)
?Install array software with Navisphere 6.x Service UI cnman790 (20)
?Cable the array to the LAN cnman510 (24)
?Set array properties in Navisphere Manager 6.x cnnav140 (25)
?Create RAID groups in Manager 6.x cnlun550 (27)
?Create LUNs on RAID groups with Manager 6.x cnlun560 (28)
?Create storage groups and connect hosts with Manager 6.x cnlun570 (29)
?Set storage system failover properties with Navi Manager (HP-UX) inpwp390 (30)
?Discover device names of CLI communication LUNs on an HP-UX server cnlun590 (31)
?Make LUNs available to HP-UX cnlun430 (32)
?Create volume groups on LUNs on an HP-UX server (PowerPath) cnlun640 (35)
?Configure PowerPath devices for an HP-UX host inpwp380 (37)
Test PowerPath inpwp070 (38)
?Collect the environment configuration information instr090 (39)
Verify the customer has completed the following for HP-UX PowerPath Table of Contents
___
___
___
___
___ Table of Contents
Verify connection between SP Agent and host system
Table of Contents
___ Table of Contents
___
___ ___
Table of Contents
___
___ Table of Contents
Verify the host is connected to the LAN
Table of Contents
Service providers begin here to continue the installation procedure
Table of Contents
___ Table of Contents
___
___ Table of Contents
___
___ port (|O|O| on a CX700/CX600 or
___
___ 1) and the SP B service port (|0|0| or ___
___
___
Remove the NULL modem cable from SP B and connect it between the laptop serial port (COM
1) and the SP A service port (|0|0| or ___
___
___ Table of Contents